Microwave Imaging Device for In-Line Food Inspection

Author(s):  
M. Ricci ◽  
L. Crocco ◽  
F. Vipiana
Author(s):  
Daniela M. Godinho ◽  
Joao M. Felicio ◽  
Tiago Castela ◽  
Nuno A. Silva ◽  
M. Lurdes Orvalho ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5545
Author(s):  
Behnaz Sohani ◽  
James Puttock ◽  
Banafsheh Khalesi ◽  
Navid Ghavami ◽  
Mohammad Ghavami ◽  
...  

In this paper, we present an investigation of different artefact removal methods for ultra-wideband Microwave Imaging (MWI) to evaluate and quantify current methods in a real environment through measurements using an MWI device. The MWI device measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. A simple two-layered phantom mimicking human head tissue is realised, applying a cylindrically shaped inclusion to emulate brain haemorrhage. Detection has been successfully achieved using the superimposition of five transmitter triplet positions, after applying different artefact removal methods, with the inclusion positioned at 0°, 90°, 180°, and 270°. The different artifact removal methods have been proposed for comparison to improve the stroke detection process. To provide a valid comparison between these methods, image quantification metrics are presented. An “ideal/reference” image is used to compare the artefact removal methods. Moreover, the quantification of artefact removal procedures through measurements using MWI device is performed.


2020 ◽  
Vol 19 (12) ◽  
pp. 2393-2397
Author(s):  
Banafsheh Khalesi ◽  
Behnaz Sohani ◽  
Navid Ghavami ◽  
Mohammad Ghavami ◽  
Sandra Dudley ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 27
Author(s):  
Mio Adachi ◽  
Tsuyoshi Nakagawa ◽  
Tomoyuki Fujioka ◽  
Mio Mori ◽  
Kazunori Kubota ◽  
...  

Purpose: Microwave radar-based breast imaging technology utilizes the principle of radar, in which radio waves reflect at the interface between target and normal tissues, which have different permittivities. This study aims to investigate the feasibility and safety of a portable microwave breast imaging device in clinical practice. Materials and methods: We retrospectively collected the imaging data of ten breast cancers in nine women (median age: 66.0 years; range: 37–78 years) who had undergone microwave imaging examination before surgery. All were Japanese and the tumor sizes were from 4 to 10 cm. Using a five-point scale (1 = very poor; 2 = poor; 3 = fair; 4 = good; and 5 = excellent), a radiologist specialized in breast imaging evaluated the ability of microwave imaging to detect breast cancer and delineate its location and size in comparison with conventional mammography and the pathological findings. Results: Microwave imaging detected 10/10 pathologically proven breast cancers, including non-invasive ductal carcinoma in situ (DCIS) and micro-invasive carcinoma, whereas mammography failed to detect 2/10 breast cancers due to dense breast tissue. In the five-point evaluation, median score of location and size were 4.5 and 4.0, respectively. Conclusion: The results of the evaluation suggest that the microwave imaging device is a safe examination that can be used repeatedly and has the potential to be useful in detecting breast cancer.


2020 ◽  
Vol 62 (5) ◽  
pp. 18-32
Author(s):  
Jorge A. Tobon Vasquez ◽  
Rosa Scapaticci ◽  
Giovanna Turvani ◽  
Marco Ricci ◽  
Laura Farina ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 533
Author(s):  
Aleksandar Janjic ◽  
Mehmet Cayoren ◽  
Ibrahim Akduman ◽  
Tuba Yilmaz ◽  
Emre Onemli ◽  
...  

SAFE (Scan and Find Early) is a novel microwave imaging device intended for breast cancer screening and early detection. SAFE is based on the use of harmless electromagnetic waves and can provide relevant initial diagnostic information without resorting to X-rays. Because of SAFE’s harmless effect on organic tissue, imaging can be performed repeatedly. In addition, the scanning process itself is not painful since breast compression is not required. Because of the absence of physical compression, SAFE can also detect tumors that are close to the thoracic wall. A total number of 115 patients underwent the SAFE scanning procedure, and the resultant images were compared with available magnetic resonance (MR), ultrasound, and mammography images in order to determine the correct detection rate. A sensitivity of 63% was achieved. Breast size influenced overall sensitivity, as sensitivity was lower in smaller breasts (51%) compared to larger ones (74%). Even though this is only a preliminary study, the results show promising concordance with clinical reports, thus encouraging further SAFE clinical studies.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 866
Author(s):  
Mengchu Wang ◽  
Rosa Scapaticci ◽  
Marta Cavagnaro ◽  
Lorenzo Crocco

Liver cancer is one of the most common liver malignancies worldwide. Thermal ablation has been recognized as a promising method for its treatment, with a significant impact on clinical practice. However, the treatment’s effectiveness is heavily dependent on the experience of the clinician and would improve if paired with an image-guidance device for treatment monitoring. Conventional imaging modalities, such as computed tomography, ultrasound, and magnetic resonance imaging, show some disadvantages, motivating interest in alternative technologies. In this framework, microwave imaging was recently proposed as a potential candidate, being capable of implementing real-time monitoring by means of low-cost and portable devices. In this work, the in silico assessment of a microwave imaging device specifically designed for liver ablation monitoring is presented. To this end, an imaging experiment involving eight Vivaldi antennas in an array configuration and a practically realizable liver phantom mimicking the evolving treatment was simulated. In particular, since the actual phantom will be realized by 3D printing technology, the effect of the plastic shells containing tissues mimicking materials was investigated and discussed. The outcomes of this study confirm that the presence of printing materials does not impair the significance of the experiments and that the designed device is capable of providing 3D images of the ablated region conveying information on its extent and evolution. Moreover, the observed results suggest possible improvements to the system, paving the way for the next stage in which the device will be implemented and experimentally assessed in the same conditions as those simulated in this study.