Measurement of Ventilatory Threshold by Respiratory Frequency

2002 ◽  
Vol 94 (3) ◽  
pp. 851-859 ◽  
Author(s):  
Teru Nabetani ◽  
Takeshi Ueda ◽  
Keisuke Teramoto

This study was conducted to assess whether respiratory frequency can be used as a valid parameter for estimating ventilatory threshold and for examining differences in exercise modes such as a cycle ergometer and a treadmill. 24 men and 12 women performed an incremental exercise test to exhaustion on a cycle ergometer and on a treadmill. Oxygen uptake, carbon dioxide output, pulmonary ventilation, ventilatory frequency, and heart rate were measured continuously every 30 sec. during the test. Three different and independent reviewers detected the ventilatory threshold point and break point of respiratory rate, which were then compared. Analysis indicated that (1) ventilatory threshold was well correlated with break point of respiratory rate for both cycle ( r = .88, p<.001) and treadmill exercise ( r = .96, p<.001). However, on the average, ventilatory threshold was only 71% (cycle) or 88% (treadmill) of break point of respiratory rare. (2) The regression equation for treadmill exercise was more accurate than that for cycling, but the detected data samples were smaller. The break point of respiratory rate was more easily detected for the cycle ergometer test (33 of 36 subjects) than for the treadmill test (only 15 of 36). The cycle ergometer test identified the break point of respiratory rate more easily than did the treadmill test. (3) There was an association between physical fitness and whether the break point of respiratory rate was detectable, and the more fit the subject (above average), the more likely the break point was to be undetected. Our study demonstrates that the break point of respiratory rate is closely associated with ventilatory threshold and that the cycle ergometer test is more conducive than the treadmill test to the detectability of break point of respiratory rate.

1988 ◽  
Vol 64 (2) ◽  
pp. 753-758 ◽  
Author(s):  
J. K. Kalis ◽  
B. J. Freund ◽  
M. J. Joyner ◽  
S. M. Jilka ◽  
J. Nittolo ◽  
...  

The effect of beta-adrenergic blockade on the drift in O2 consumption (VO2 drift) typically observed during prolonged constant-rate exercise was studied in 14 healthy males in moderate heat at 40% of maximal O2 consumption (VO2max). After an initial maximum cycle ergometer test to determine the subjects' control VO2max, subjects were administered each of three medications: placebo, atenolol (100 mg once daily), and propranolol (80 mg twice daily), in a randomized double-blind fashion. Each medication period was 5 days in length and was followed by a 4-day washout period. On the 3rd day of each medication period, subjects performed a maximal cycle ergometer test. On the final day of each medication period, subjects exercised at 40% of their control VO2max for 90 min on a cycle ergometer in a warm (31.7 +/- 0.3 degrees C) moderately humid (44.7 +/- 4.7%) environment. beta-Blockade caused significant (P less than 0.05) reductions in VO2max, maximal minute ventilation (VEmax), maximal heart rate (HRmax), and maximal exercise time. Significantly greater decreases in VO2max, VEmax, and HRmax were associated with the propranolol compared with the atenolol treatment. During the 90-min submaximal rides, beta-blockade significantly reduced heart rate. Substantially lower values for O2 consumption (VO2) and minute ventilation (VE) were observed with propranolol compared with atenolol or placebo. Furthermore, VO2 drift and HR drift were observed under atenolol and placebo conditions but not with propranolol. Respiratory exchange ratio decreased significantly over time during the placebo and atenolol trials but did not change during the propranolol trial.(ABSTRACT TRUNCATED AT 250 WORDS)


1998 ◽  
Vol 12 (1) ◽  
pp. 12-17
Author(s):  
Paul M. Vanderburgh ◽  
Greg Daniels ◽  
Todd A. Crowder ◽  
Tony Lachowetz ◽  
Robb Elliott

2020 ◽  
Vol 41 (10) ◽  
pp. 661-668
Author(s):  
Kasper Sørensen ◽  
Mathias Krogh Poulsen ◽  
Dan Stieper Karbing ◽  
Peter Søgaard ◽  
Johannes Jan Struijk ◽  
...  

AbstractThe purpose of this study was to investigate the correlation between the seismocardiogram and cardiorespiratory fitness. Cardiorespiratory fitness can be estimated as VO2max using non-exercise algorithms, but the results can be inaccurate. Healthy subjects were recruited for this study. Seismocardiogram and electrocardiogram were recorded at rest. VO2max was measured during a maximal effort cycle ergometer test. Amplitudes and timing intervals were extracted from the seismocardiogram and used in combination with demographic data in a non-exercise prediction model for VO2max. 26 subjects were included, 17 females. Mean age: 38.3±9.1 years. The amplitude following the aortic valve closure derived from the seismocardiogram had a significant correlation of 0.80 (p<0.001) to VO2max. This feature combined with age, sex and BMI in the prediction model, yields a correlation to VO2max of 0.90 (p<0.001, 95% CI: 0.83–0.94) and a standard error of the estimate of 3.21 mL·kg−1·min−1 . The seismocardiogram carries information about the cardiorespiratory fitness. When comparing to other non-exercise models the proposed model performs better, even after cross validation. The model is limited when tracking changes in VO2max. The method could be used in the clinic for a more accurate estimation of VO2max compared to current non-exercise methods.


2007 ◽  
Vol 30 (2) ◽  
pp. 138-149 ◽  
Author(s):  
Nuria Garatachea ◽  
Euclides Cavalcanti ◽  
David García-López ◽  
Javier González-Gallego ◽  
Jose A. de Paz

2004 ◽  
Vol 36 (Supplement) ◽  
pp. S118
Author(s):  
Shannon Crumpton ◽  
Henry Williford ◽  
Michele Scharff-Olson ◽  
Shawn OʼMailia ◽  
Elese Woollen ◽  
...  

2004 ◽  
Vol 36 (Supplement) ◽  
pp. S118
Author(s):  
Shannon Crumpton ◽  
Henry Williford ◽  
Michele Scharff-Olson ◽  
Shawn O??Mailia ◽  
Elese Woollen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document