scholarly journals The assessment of consecutive 4D-CT scans during simulation for lung stereotactic body radiation therapy patients

2020 ◽  
Vol 26 (4) ◽  
pp. 193-199
Author(s):  
Milovan Savanovic ◽  
Bojan Strbac ◽  
Drazan Jaros ◽  
Jean-Noel Foulquier

AbstractPurpose: To evaluate the breathing amplitude, tumor motion, patient positioning, and treatment volumes among consecutive four-dimensional computed tomography (4D-CT) scans, during the simulation for lung stereotactic body radiation therapy (SBRT).Material and methods: The variation and shape of the breathing amplitude, patient positioning, and treatment volumes were evaluated for 55 lung cancer patients after consecutive 4D-CT acquisitions, scanned at one-week intervals. The impact of variation in the breathing amplitude on lung tumor motion was determined for 20 patients. The gross tumor volume (GTV) was contoured from a free-breathing CT scan and at ten phases of the respiratory cycle, for both 4D-CTs (440 phases in total).Results: Breathing amplitude decreased by 3.6 (3.4-4.9) mm, tumor motion by 3.2 (0.4-5.0) mm while breathing period increased by 4 (2-6) s, inter-scan for 20 patients. Intra-scan variation was 4 times greater for the breathing amplitude, 5 times for the breathing period, and 8 times for the breathing cycle, comparing irregular versus regular breathing patterns for 55 patients. Using coaching, the breathing amplitude increases 3 to 8 mm, and the breathing period 2 to 6 s. Differences in the contoured treatment volumes were less than 10% between consecutive scans. Patient positioning remained stable, with a small inter-scan difference of 1.1 (0.6-1.4) mm.Conclusion: Decreasing the inter-scan breathing amplitude decreases the tumor motion reciprocally. When the breathing amplitude decreases, the breathing period increases at inter- and intra-scan, especially during irregular breathing. Coaching improves respiration, keeping the initial shape of the breathing amplitude. Contoured treatment volumes and patient positioning were reproducible through successive scans.

2019 ◽  
Vol 25 (1) ◽  
pp. 29-34
Author(s):  
Ramaa Lingaiah ◽  
Md Abbas Ali ◽  
Ummay Kulsum ◽  
Muhtasim Aziz Muneem ◽  
Karthick Raj Mani ◽  
...  

Abstract Aim: To estimate the Gross Tumor Volume (GTV) using different modes (axial, helical, slow, KV-CBCT & 4D-CT) of computed tomography (CT) in pulmonary tumors. Materials & Methods: We have retrospectively included ten previously treated case of carcinoma of primary lung or metastatic lung using Stereotactic Body Radiation Therapy (SBRT) in this study. All the patients underwent 4 modes of CT scan Axial, Helical, Slow & 4D-CT using GE discovery 16 Slice PET-CT scanner and daily KV-CBCT for the daily treatment verification. For standardization, all the patients underwent different modes of scan using 2.5 mm slice thickness, 16 detectors rows and field of view of 400mm. Slow CT was performed using axial mode scan by increasing the CT tube rotation time (typically 3 – 4 sec.) as per the breathing period of the patients. 4D-CT scans were performed and the entire respiratory cycle was divided into ten phases. Maximum Intensity Projections (MIP), Minimum Intensity Projections (MinIP) and Average Intensity Projections (AvIP) were derived from the 10 phases. GTV volumes were delineated for all the patients in all the scanning modes (GTVAX - Axial, GTVHL - Helical, GTVSL – Slow, GTVMIP -4DCT and GTVCB – KV-CBCT) in the Eclipse treatment planning system version 11.0 (M/S Varian Medical System, USA). GTV volumes were measured, documented and compared with the different modes of CT scans. Results: The mean ± standard deviation (range) for MIP, slow, axial, helical & CBCT were 36.5 ± 40.5 (2.29 – 87.0), 35.38 ± 39.52 (2.1 – 82), 31.95 ± 37.29 (1.32 – 66.9), 28.98 ± 33.36 (1.01 – 65.9) & 37.16 ± 42.23 (2.29 – 92). Overall underestimation of helical scan and axial scan compared to MIP is 21% and 12.5%. CBCT and slow CT volume has a good correlation with the MIP volume. Conclusion: For SBRT in lung tumors better to avoid axial and helical scan for target delineation. MIP is a still a golden standard for the ITV delineation, but in the absence of 4DCT scanner, Slow CT and KV-CBCT data may be considered for ITV delineation with caution.


2007 ◽  
Vol 32 (2) ◽  
pp. 92-101 ◽  
Author(s):  
Warren D. D’Souza ◽  
Daryl P. Nazareth ◽  
Bin Zhang ◽  
Chad Deyoung ◽  
Mohan Suntharalingam ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document