The Soviet/Russian Space Suit History Part II - The Space Stations Era, 1970's to 1990's

Author(s):  
Ake Ingemar Skoog
Keyword(s):  
Author(s):  
Heather Paul ◽  
David Converse ◽  
Steve Dionne ◽  
Jeff Moser
Keyword(s):  

1995 ◽  
Author(s):  
V. I. Chadov ◽  
S. N. Filipenkov ◽  
L. R. Iseev ◽  
V. N. Polyakov ◽  
G. F. Vorobiev

Author(s):  
Yaritza Bernal ◽  
K. Han Kim ◽  
Elizabeth Benson ◽  
Sarah Jarvis ◽  
Lauren Harvill ◽  
...  

The objective of this study was to develop and deploy a novel motion capture system that utilizes off-the-shelf, dive-rated hardware to measure 3-D whole body reach envelopes of space suits in an underwater analog, which simulates a microgravity environment. The accuracy of the developed system was compared to a gold standard motion capture system in a dry-land condition before deployment. This study is ultimately aimed at providing a methodology for quantitative metrics to evaluate and compare the mobility performances of a newly developed prototype space suit versus an existing space suit at the Neutral Buoyancy Laboratory (NBL) at NASA’s Johnson Space Center.


2021 ◽  
Author(s):  
Donald Hendrix

<p>With the Artemis mission set to launch in 2024, returning humans to the lunar surface for the first time in over half a century, it is imperative to ensure human health and safety on a variety of fronts. Lunar dust exposure is one of many areas of concern regarding astronaut health and safety. During the Apollo missions it was reported that lunar dust was a nuisance and induced allergic-like symptoms upon exposure. In addition, it was also reported that instruments became coated with dust that was difficult to remove, and that the dust adhered to everything and tore through space suit fabric. Numerous inhalation studies have determined that lunar dust is more toxic than analogous terrestrial materials but less so than silica dust. Apollo dust mitigation systems were successful on some missions but failed on others. As humans are to stay on the lunar surface for extended periods relative to the Apollo missions, it is vital to fabricate instruments that would address the lunar dust problem with greater reliability. There must be multiple steps to remove all lunar dust, including the ultra-fine <10 µm fraction which was the most difficult dust size to remove. There must be multiple steps regarding lunar dust removal including a chamber to remove dust and de-suit, and a vacuum with high level HEPA filtration to remove dust. The first chamber would be to filter out any dust that comes into the module from the outside. Once all the air is clear, then the next step would be to remove any remaining dust on the suits using a hand-held vacuum with a HEPA H14 filter which only allows up to a maximum 0.005% of particles 100 nm in size to pass through the filter. Then, it would be safe to de-suit. It would be wise to have a second chamber between the first chamber and the command center of the lunar module that would vacuum any remaining dust before opening to the main command chamber. Ultra-high quality HEPA filters of both the chamber and hand-held vacuum systems should be replaced frequently to maintain optimal dust mitigation. Investing time and resources into lunar dust mitigation should be a top priority for the upcoming Artemis mission to avoid the issues encountered on the Apollo missions.</p>


Author(s):  
Karen S. Young ◽  
K. Han Kim ◽  
Sudhakar Rajulu

Objective This study aims to identify the change in anthropometric measurements during spaceflight due to microgravity exposure. Background Comprehensive and accurate anthropometric measurements are crucial to assess body shape and size changes in microgravity. However, only limited anthropometric data have been available from the astronauts in spaceflight. Methods A new photogrammetry-based technique in combination with a tape-measure method was used for anthropometric measurements from nine crewmembers on the International Space Station. Measurements included circumference and height for body segments (chest, waist, bicep, thigh, calf). The time-dependent variations were also assessed across pre-, in-, and postflight conditions. Results Stature showed a biphasic change with up to 3% increase at the early flight phase, followed by a steady phase during the remaining flight. Postflight measurements returned to a similar level of the preflight. Other linear measurements, including acromion height, showed similar trends. The chest, hip, thigh, and calf circumferences show overall decrease during the flight up to 11%, then returned close to the preflight measurement at postflight. Conclusion The measurements from this study provide critical information for the spacesuit and hardware design. The ground-based assessments for spacesuit fit needs to be revalidated and adjusted for in-flight extravehicular activities from this data. Application These data can be useful for space suit design as well as habitat, vehicle, and additional microgravity activities such as exercise, where the body shape changes can affect fit, performance, and human factors of the overall design.


1994 ◽  
Author(s):  
Isaak P. Abramov ◽  
Anatoly Yu. Stoklitsky ◽  
Arnold S. Barer ◽  
Sergei N. Filipenkov

1964 ◽  
Vol 10 (11) ◽  
pp. 809-816
Author(s):  
W. E. Dance ◽  
D. L. Edens ◽  
B. J. Farmer ◽  
J. H. Johnson
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document