Long-term results of delayed removal of the intraocular foreign body in open eyeball injury with damage to the posterior segment of the eye

Author(s):  
U.S. Fayzieva ◽  
◽  
M.D. Gulyamova ◽  
O.I. Ikramov ◽  
◽  
...  

Purpose. To study the clinical efficacy of the long-term results of a step-by-step method of surgical treatment of open eye trauma complicated by the presence of the intraocular foreign body (IFB) in the posterior segment, including primary surgical treatment (PST) and delayed vitreoretinal surgery with IFB extraction within 24 hours after PST. Material and methods. The clinical efficacy of delayed IFB removal within 2 years was studied in 32 eyes with open trauma of the eyeball complicated by the presence of IFB in the posterior segment. Concomitant traumatic complications included partial hemophthalmos (84.4%) and rhegmatogenous retinal detachment (RD) (59.4%). Results. By the end of 2 years of follow-up, the anatomical effect was observed in all examined 21 eyes, including 15 eyes (71.4%) with hemophthalmos and 13 eyes (61.9%) with traumatic retinal detachment. In this case, recurrence of RD occurred in 7 eyes, post-traumatic traction RD- in 3 eyes. Functional effect with improved visual acuity was in 12 eyes (57.1%). At the same time, the MCVA was 0.3±0.05 (0.15–0.5). Conclusion. The presented method made it possible to achieve a stable anatomical effect and stable functional results, even in the presence of severe trauma complicated by total hemophthalmos and retinal detachment, in the long term. Key words: open eyeball injury, intraocular foreign body, primary surgical treatment, transvitreal intraocular foreign body extraction, post-traumatic traction retinal detachment.

2010 ◽  
Vol 67 (3) ◽  
pp. 213-215
Author(s):  
Ivan Stefanovic ◽  
Bojana Dacic ◽  
Sasa Novak ◽  
Dragan Veselinovic ◽  
Predrag Jovanovic ◽  
...  

Background/Aim. In cases of blurred optic media the ultrasound diagnostics offers useful data about eventual presence of intraocular foreign body as well as about its precise localization in the eye. The aim of this study was to retrospectively analyze echographic findings in patients with the diagnosis of intraocular foreign body with a special interest in localizations of a intraocular foreign body in the eye and the presence of an eventual infection - endophthalmitis. The aim of this study was also to confirm the localization of intraocular foreign body by echography and to test the precision of this method. Methods. We performed analysis of all cases that had been referred to the ultrasound diagnostices, in which the presence of intraocular foreign body had been confirmed in the period of one year. All examinations were done with B-scan and were confirmed during the surgery - vitrectomy. Results. In the one-year period we were contacted by 27 patients with intraocular foreign body. In one injured eye the intraocular foreign body was in the lens (3.7%), in 10 injured eyes (37.03%) intraocular foreign body was in the vitreal body. In 15 patients (55.5%) intraocular foreign body was fixed in the retina. In one patient (3.7%) there was a perforating injury, intraocular foreign body was found in the retrobulbar part of the orbit. In 7 injured eyes (25.9%), with the presence of intraocular foreign body, we found signs of endophthalmitis (organized blurring in vitreal space, thickened choroid). Other accompanying echographic findings were: blood in vitreal space, haemophthalmus in 12 cases (44.4%), retinal detachment in 5 cases (18.5%) and subretinal hemorrhagies in 4 cases (14.8%). Conclusion. Ultrasound diagnostics can very precisely show the localization of intraocular foreign body in the eye that is very important in the choice of approach and timing of surgical treatment. Also the echographic diagnostics may find an accompanying endophthalmitis in the posterior segment of the eye, that is very important for an urgent therapeutic approach.


2019 ◽  
Vol 5 (12) ◽  
pp. 156-162
Author(s):  
M. Sabyraliev

Surgical treatment of patients with spinal injuries, accompanied by traumatic stenosis of the spinal canal, is an urgent and discussed problem of modern vertebrology. Surgical treatment of 111 patients with various injuries of the thoracolumbar spine was performed. In 40 patients, post-traumatic stenosis was eliminated using ligamentotaxis using transpedicular osteosynthesis. The immediate results of treatment were followed up in all patients: good results were obtained in 33 (82.5%) cases; satisfactory — in 6 (15.0%), unsatisfactory — in 1 (2.5%). Long-term results with a follow-up of more than 1 year were followed up in 27 (67.5%) patients; good results were obtained in 20 (74.0%), satisfactory in 7 (25.0%).


2018 ◽  
Vol 10 (1) ◽  
pp. 66-72 ◽  
Author(s):  
Sanjita Sharma ◽  
Raba Thapa ◽  
Sanyam Bajimaya ◽  
Eli Pradhan ◽  
Govinda Poudyal

Purpose: To evaluate clinical characteristics, visual outcomes and globe survival after intraocular foreign body removal from posterior segment via pars plana approach. Methods: A hospital based retrospective study. All the patients of penetrating eye injury with intraocular foreign body in posterior segment as detected by computed tomography were enrolled from 2012 to 2014.Results: Thirty patients of 30 eyes were included. The mean age was 27.7 years. (2-52). Twenty-four (80%) were male. Out of 30 eyes 19 (63.3%) eyes had injury at Zone 1 and 11 (36.7%) eyes had injury at Zone 2. The mean time spent between primary repair following surgery and intra ocular foreign body removal, was 15.47 days. Retinal detachment and endophthalmitis prior to intraocular foreign body removal was present in 9/30 of eyes. We looked for correlation between post operative Phthisis bulbi with zone of injury and pre operative endophthalmitis and preoperative retinal detachment. However, p value for the above correlation was more than 0.552 and 0.815 respectively, which was statistically not significant.Conclusions: The eyes with posterior segment intraocular foreign bodies showing clinical features of preoperative endophthalmitis, retinal detachment and the zone of injury also did not have any direct significance with globe survival.  


2001 ◽  
Vol 115 (5) ◽  
pp. 425-427 ◽  
Author(s):  
P. S. Arunachalam ◽  
D. S. Cameron

The surgical treatment of a pharyngeal pouch with endoscopic stapling diverticulotomy is a relatively new concept. Long-term results and complications are yet to be fully studied. We describe a patient who developed persistent pharyngeal pain and foreign body sensation due to retention of a clump of staples at the cricopharyngeal sphincter. This complication has not been reported before. This case highlights the need for repeat endoscopy rather than a barium swallow X-ray if the patients are symptomatic after stapling procedures.


2020 ◽  
Vol 8 (5) ◽  
pp. 375-378
Author(s):  
Dr. Amit C Porwal ◽  
◽  
Dr. Hardik Jain ◽  
Dr. Pratik Mahajan ◽  
◽  
...  

Intraocular foreign bodies (IOFBs) are an important cause of visual loss. The current case describesa case of retained intraocular foreign body with secondary retinal detachment in a phakic eye in a38-year-old man. The foreign body was safely removed through the sclerotomy port withouttouching the crystalline lens. The current case report wanted to show the anatomic and visualoutcomes of vitreoretinal surgery in such cases.


2013 ◽  
Vol 141 (7-8) ◽  
pp. 516-518
Author(s):  
Aleksandar Gakovic ◽  
Igor Kovacevic ◽  
Jovana Bisevac ◽  
Bojana Radovic ◽  
Katarina Cubrilo ◽  
...  

Introduction. Penetrated injuries are most difficult injuries of the eye. Intraocular foreign body (IOFB) may lodge in any of the structures it encounters, from anterior chamber to the retina and choroid. Notable effects caused by foreign body injury include traumatic cataract, vitreous liquefaction, retinal and subretinal hemorrhages, retinal detachment and development of endophtalmitis. Case Outline. A 49?year?old man sustained injury of the right eye with a piece of metal wire. On admission visual acuity was VOD: 1.0 and lower intraocular tension TOD=6 mmHg (10?22 mmHg). Corneal entry wound was noticed near limb on 11h with a prominating foreign body of 18 mm in length that passed through the iris, lens and vitreous. X?ray findings confirmed existence of a large foreign body extending along the entire length of the globe. IOFB removal was done with anatomic forceps. On postoperative detailed clinical examination we observed retinal rupture in the upper temporal quadrant fitting in the area of the IOFB damaged retina. Laser photocoagulation of retinal tear (laser retinal barrage) was done. Visual acuity on discharge was the same (1.0) and intraocular tension was within normal limits (10 mmHg). Conclusion. Penetrated injury of eye requires detailed examination of all eye structures, beginning from the anterior to posterior segment. Timely diagnosed ruptures of the posterior segment of eye before the development of traumatic cataract, and adequate therapeutic procedures prevent serious complications of IOFB penetrated eye injury such as retinal detachment and permanent reduction of visual acuity.


2021 ◽  
Vol 13 (1) ◽  
pp. 22-30
Author(s):  
Bikram Bahadur Thapa ◽  
Sweta Singh ◽  
Gyanendra Lamichhane ◽  
Shanti Gurung ◽  
Saurav Piya

Introduction: Posterior segment retained Intraocular foreign body (IOFB) management is challenging. Facility of pars plana vitrectomy (PPV) and availability of well trained vitreo retina surgeons are the basic need to accomplish this work.  Encircling band provide permanent 360° support to close the anterior retinal break and prevent traction on the retina. The objective of this study is to analyse the clinical characteristics and predictors of the final visual outcome and survival of the globe in cases of retained IOFB in the posterior eye segment. Materials and methods: A hospital based retrospective observational study was conducted. All the patients of retained IOFB in the posterior segment presented from January 2016 to June 2019 were enrolled. Patients presented with visual acuity of NPL were excluded. Statistical analysis was performed using a variety of tests using SPSS version 21.   Results: Forty eyes of 40 patients were included. The mean age was 27.08±10.68 years (range 5-66). 95% of our patients were male. Most of them (52.5%) worked on the farm. 26(65%) of 40 eyes had Zone I injury. The median time spent before presentation was 13.5 day. Retinal detachment, vitreous hemorrhage, and endophthalmitis were present in 15, 23 and 5 eyes, respectively, before IOFB removal. The mean LogMAR visual acuity was improved significantly from 2.50±0.87 to 1.33± 1.01 (p=0.003). Poor presenting visual acuity, retinal detachment and large diameter of IOFB were found as the predictor of poor final visual acuity. Conclusion:  Pars plana vitrectomy by a vitreo retinal surgeon can give encouraging results in the cases of retained posterior segment IOFB. Poor presenting visual acuity, large diameter of IOFB and RD before IOFB removal are predictors of poor visual outcome.


Sign in / Sign up

Export Citation Format

Share Document