scholarly journals ION-SELECTIVE ELECTRODE FOR DETERMINATION OF METFORMIN IN PHARMACEUTICAL PREPARATIONS

Author(s):  
Геннадий Иванович Мантров ◽  
Мариана Александровна Феофанова ◽  
Егор Максимович Грачев

Описана конструкция и электроаналитические характеристики ионселективного электрода (ИСЭ) для количественного определения метформина. В качестве электродноактивных соединений в ИСЭ были использованы ионные ассоциаты метформина с фосфорновольфрамовой(ФВК), фосфорномолибденовой(ФМК) и кремний вольфрамовой кислотами (КВК). Проведено потенциометрическое определение метформина в фармацевтических препаратах. The construction and electroanalytical characteristics of ion-selective electrode (ISE) for metformin are described. Ion pair of metformin with heteropolyacids were tested as electroactive materials for ionometric sensor controls. The ISE was used for direct potentiometry of metformin.

2015 ◽  
Vol 12 (1) ◽  
pp. 188-196
Author(s):  
Baghdad Science Journal

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .


1979 ◽  
Vol 62 (2) ◽  
pp. 315-319
Author(s):  
Saad S M Hassan ◽  
Mohamed T Zaki ◽  
Mohamed H Eldesouki

Abstract Simple, rapid, and accurate methods have been developed for determining vitamin Bx in pharmaceutical preparations without prior separation of the vitamin. The methods are based on the desulfurization reaction with potassium plumbite and measurement of the unreacted lead (II) ions at 217 nm using atomic absorption spectroscopy (AAS), or by titration with EDTA at pH 4.5 with the lead ion selective electrode and Gran's plot. The results compare favorably with those obtained using the USP fluorometric method. Recoveries of pure vitamin Bx averaged 99.1%, with a standard deviation of 0.8%, and 99.0%, with a standard deviation of 0.7%, for the AAS and ion selective electrode procedures, respectively.


2009 ◽  
Vol 2009 ◽  
pp. 1-7 ◽  
Author(s):  
Hassan Arida ◽  
Mona Ahmed ◽  
Abdallah Ali

The fabrication and electrochemical evaluation of two PVC membrane-based Ion-Selective electrodes responsive for ramipril drug have been proposed. The sensitive membranes were prepared using ramipril-phosphomolibdate and ramipril-tetraphenylborate ion-pair complexes as electroactive sensing materials in plasticized PVC support. The electrodes based on these materials provide near-Nernestian response (sensitivity of53±0.5–54±0.5 mV/concentration decade) covering the concentration range of1.0×10-2–1.0×10-5 molL−1with a detection limit of3.0×10-6–4.0×10-6 molL−1. The suggested electrodes have been successfully used in the determination of ramipril drug in some pharmaceutical formulations using direct potentiometry with average recovery of >96% and mean standard deviation of <3% (n=5).


1981 ◽  
Vol 27 (8) ◽  
pp. 1435-1438 ◽  
Author(s):  
G B Levy

Abstract The advent of ion-selective electrodes made possible the potentiometry of sodium in serum and plasma. These methods were based on dilution of serum, as done in flame photometry, and the results were identical. Analysis of whole blood precludes dilution and so "direct" potentiometry was developed. Results by this technique are variable but tend to compensate for the spurious hyponatremias found by the "indirect" dilution methods due to displacement of volume by lipids and protein. However, there is no unambiguous theoretical basis on which to choose between the various direct ion-selective-electrode techniques and instruments. As an alternative, I propose use of current indirect methods, with numerical correction for the shift in normal sodium values in the presence of abnormal lipid and (or) protein. A table was constructed for making such corrections.


Sign in / Sign up

Export Citation Format

Share Document