scholarly journals Numerical Simulation of Temperature Distribution in the Gas Turbine Blade

Author(s):  
Dariusz Jakubek

This paper concentrates on temperature distribution in the gas turbine blade equipped by the cooling holes system on transient heat transfer. The present study requires the specification of internal and external boundary conditions. The calculations had been done using both Crank-Nicolson algorithm, explicit and implicit methods, in which different heat transfer coefficients on internal cooling surfaces of the holes were applied. The value of coefficients has a direct and crucial impact on the final result. The heat transfer coefficient of cooling the working surface of the of heat pipes was 1600 W/(m2K). It was found that there were no significant differences of temperature distribution in comparison of results from explicit method in the Ansys analysis, Crank-Nicolson algorithm and implicit method in Matlab. The simulation is based on Finite Element Method, which uses the Crank Nicolson algorithm.

Author(s):  
E. Findeisen ◽  
B. Woerz ◽  
M. Wieler ◽  
P. Jeschke ◽  
M. Rabs

This paper presents two different numerical methods to predict the thermal load of a convection-cooled gas-turbine blade under realistic operating temperature conditions. The subject of the investigation is a gas-turbine rotor blade equipped with an academic convection-cooling system and investigated at a cascade test-rig. It consists of three cooling channels, which are connected outside the blade, so allowing cooling air temperature measurements. Both methods use FE models to obtain the temperature distribution of the solid blade. The difference between these methods lies in the generation of the heat transfer coefficients along the cooling channel walls which serve as a boundary condition for the FE model. One method, referred to as the FEM1D method, uses empirical one-dimensional correlations known from the available literature. The other method, the FEM2D method, uses three-dimensional CFD simulations to obtain two-dimensional heat transfer coefficient distributions. The numerical results are compared to each other as well as to experimental data, so that the benefits and limitations of each method can be shown and validated. Overall, this paper provides an evaluation of the different methods which are used to predict temperature distributions in convection-cooled gas-turbines with regard to accuracy, numerical cost and the limitations of each method. The temperature profiles obtained in all methods generally show good agreement with the experiments. However, the more detailed methods produce more accurate results by causing higher numerical costs.


Author(s):  
James Batstone ◽  
David Gillespie ◽  
Eduardo Romero

A novel form of gas turbine blade or vane cooling in which passages repeatedly branch within the wall of the cooled component is introduced in this paper. These so called dendritic cooling geometries offer particular performance improvements compared to traditional cooling holes where the external cross flow is low, and conventional films have a tendency to lift off the surface. In these regions improved internal cooling efficiency is achieved, while the coolant film is ejected at a low momentum ratio resulting in reduced aerodynamic losses between the film and hot gases, and a more effective surface film. By varying the number of branches of the systems at a particular location it is possible to tune the flow and heat transfer to the requirements at that location whilst maintaining the pressure margin. The additional loss introduced using the internal branching structure allows a full film-coverage arrangement of holes at the external blade surface. In this paper the results of transient heat transfer experiments characterising the internal heat transfer coefficient distribution in large scale models of dendritic passages are reported. Experiments were conducted with 1, 2 and 3 internal flow branches at a range of engine representative Reynolds numbers and exit momentum ratios. CFD models are used to help explain the flow field in the cooling passages. Furthermore the sensitivity of the pressure loss to the blowing ratio at the exit of the cooling holes is characterised and found to be inversely proportional to the number of branches in the dendritic system. Surprisingly the highly branched systems generally do not exhibit the highest pressure losses.


1985 ◽  
Vol 107 (4) ◽  
pp. 991-997 ◽  
Author(s):  
C. Camci ◽  
T. Arts

This paper deals with an experimental investigation of heat transfer across the suction side of a high-pressure, film-cooled gas turbine blade and with an attempt to numerically predict this quantity both with and without film cooling. The measurements were performed in the VKI isentropic compression tube facility under well-simulated gas turbine conditions. Data measured in a stationary frame, with and without film cooling, are presented. The predictions of convective heat transfer, including streamwise curvature effects, are compared with the measurements. A new approach to determine the augmented mixing lengths near the ejection holes on a highly convex wall is discussed and numerical results agree well with experimentally determined heat transfer coefficients in the presence of film cooling.


Author(s):  
Naris Pattanaprates ◽  
Ekachai Juntasaro ◽  
Varangrat Juntasaro

Abstract The present work is aimed to investigate whether the modification to the bend geometry of a multipass internal cooling passage in a gas turbine blade can enhance heat transfer and reduce pressure drop. The two-pass channel and the four-pass channel are modified at the bend from the U shape to the bulb and bow shape. The first objective of the work is to investigate whether the modified design will still improve heat transfer with reduced pressure drop in a four-pass channel as in the case of a two-pass channel. It is found out that, unlike the two-pass channel, the heat transfer is not improved but the pressure drop is still reduced for the four-pass channel. The second objective is to investigate the rotating effect on heat transfer and pressure drop in the cases of two-pass and four-pass channels for both original and modified designs. It is found out that heat transfer is improved with reduced pressure drop for all cases. However, the modified design results in the less improvement on heat transfer and lower reduced pressure drop as the rotation number increases. It can be concluded from the present work that the modification can solve the problem of pressure drop without causing the degradation of heat transfer for all cases. The two-pass channel with modified bend results in the highest heat transfer and the lowest pressure drop for rotating cases.


2001 ◽  
Vol 7 (6) ◽  
pp. 415-424 ◽  
Author(s):  
Hui Du ◽  
Srinath V. Ekkad ◽  
Je-Chin Han ◽  
C. Pang Lee

Detailed heat transfer coefficient and film effectiveness distributions over a gas turbine blade with film cooling are obtained using a transient liquid crystal image technique. The test blade has three rows of film holes on the leading edge and two rows each on the pressure and suction surfaces. A transient liquid crystal technique maps the entire blade midspan region, and helps provide detailed measurements, particularly near the film hole. Tests were performed on a five-blade linear cascade in a low-speed wind tunnel. The mainstream Reynolds number based on cascade exit velocity is5.3×105. Two different coolants (air andCo2) were used to simulate coolant density effect. Coolant blowing ratio was varied between 0.8 and 1.2 for air injection and 0.4–1.2 forCo2injection. Results show that film injection promotes earlier laminar-turbulent boundary layer transition on the suction surface and also enhances local heat transfer coefficients (up to 80%) downstream of injection. An increase in coolant blowing ratio produces higher heat transfer coefficients for both coolants. This effect is stronger immediately downstream of injection holes. Film effectiveness is highest at a blowing ratio of 0.8 for air injection and at a blowing ratio of 1.2 forCo2injection. Such detailed results will help provide insight into the film cooling phenomena on a gas turbine blade.


Author(s):  
Y. Mick ◽  
B. Wörz ◽  
E. Findeisen ◽  
P. Jeschke ◽  
V. Caspary

This paper presents a study of the temperature distribution of a convection cooled gas turbine blade under realistic operating temperature conditions using experimental and numerical methods. The analysis is performed experimentally in a linear cascade with exhaust gas from a kerosene combustor. Detailed information at different operating points is taken from the experiments for which conjugate heat transfer (CHT) simulations with ANSYS CFX are carried out. By comparing the experimental and numerical results, the required complexity of the simulations is defined. The subject of this study is a gas turbine rotor blade equipped with a state-of-the-art internal convection cooling system. The test rig enables the examination of the blade at temperatures up to 1300K. The temperature distribution of the blade is measured using thermocouples. The calculations are carried out using the SST turbulence model, the Gamma Theta transition model and the discrete transfer radiation model. The influence of hot gas properties and radiation effects are analysed at three different operating points. This paper gives a quantitative overview of the impact of the mentioned parameters on temperature level and distribution as well as thermal stresses in a convection cooled blade under realistic engine temperature conditions.


Sign in / Sign up

Export Citation Format

Share Document