POST-CONCUSSIVE CHANGES IN BALANCE AND POSTURAL STABILITY MEASURED WITH CANESENSE™ AND THE BALANCE ERROR SCORING SYSTEM (BESS) IN DIVISION I COLLEGIATE FOOTBALL PLAYERS: A CASE SERIES

2019 ◽  
Vol 14 (2) ◽  
pp. 296-307 ◽  
Author(s):  
Luis A. Feigenbaum ◽  
Kyoung J Kim ◽  
Ignacio A. Gaunaurd ◽  
Lee D. Kaplan ◽  
Vincent A. Scavo ◽  
...  
2016 ◽  
Vol 25 (2) ◽  
pp. 133-136 ◽  
Author(s):  
Jaclyn B. Caccese ◽  
Thomas W. Kaminski

Context:The Balance Error Scoring System (BESS) is the current standard for assessing postural stability in concussed athletes on the sideline. However, research has questioned the objectivity and validity of the BESS, suggesting that while certain subcategories of the BESS have sufficient reliability to be used in evaluation of postural stability, the total score is not reliable, demonstrating limited interrater and intrarater reliability. Recently, a computerized BESS test was developed to automate scoring.Objective:To compare computerderived BESS scores with those taken from 3 trained human scorers.Design:Interrater reliability study.Setting:Athletic training room.Patients:NCAA Division I student athletes (53 male, 58 female; 19 ± 2 y, 168 ± 41 cm, 69 ± 4 kg).Interventions:Subjects were asked to perform the BESS while standing on the Tekscan (Boston, MA) MobileMat® BESS. The MobileMat BESS software displayed an error score at the end of each trial. Simultaneously, errors were recorded by 3 separate examiners. Errors were counted using the standard BESS scoring criteria.Main Outcome Measures:The number of BESS errors was computed for the 6 stances from the software and each of the 3 human scorers. Interclass correlation coefficients (ICCs) were used to compare errors for each stance scored by the MobileMat BESS software with each of 3 raters individually. The ICC values were converted to Fisher Z scores, averaged, and converted back into ICC values.Results:The double-leg, single-leg, and tandem-firm stances resulted in good agreement with human scorers (ICC = .999, .731, and .648). All foam stances resulted in fair agreement.Conclusions:Our results suggest that the MobileMat BESS is suitable for identifying BESS errors involving each of the 6 stances of the BESS protocol. Because the MobileMat BESS scores consistently and reliably, this system can be used with confidence by clinicians as an effective alternative to scoring the BESS.


Concussion ◽  
2019 ◽  
Vol 4 (4) ◽  
pp. CNC66
Author(s):  
Travis White-Schwoch ◽  
Jennifer Krizman ◽  
Kristi McCracken ◽  
Jamie K Burgess ◽  
Elaine C Thompson ◽  
...  

Aim: Neurosensory tests have emerged as components of sport-related concussion management. Limited normative data are available in healthy, nonconcussed youth athletes. Patients & methods/results: In 2017 and 2018, we tested 108 youth tackle football players immediately before their seasons on the frequency-following response, Balance Error Scoring System, and King-Devick test. We compared results with published data in older and/or and nonathlete populations. Performance on all tests improved with age. Frequency-following response and Balance Error Scoring System results aligned with socioeconomic status. Performance was not correlated across neurosensory domains. Conclusion: Baseline neurosensory functions in seven 14-year-old male tackle football players are consistent with previously published data. Results reinforce the need for individual baselines or demographic-specific norms and the use of multiple neurosensory measures in sport-related concussion management.


2018 ◽  
Vol 50 (10) ◽  
pp. 1998-2006 ◽  
Author(s):  
SUSAN M. LINDER ◽  
SARAH J. OZINGA ◽  
MANDY MILLER KOOP ◽  
TANUJIT DEY ◽  
RICHARD FIGLER ◽  
...  

2013 ◽  
Vol 47 (5) ◽  
pp. e1.35-e1
Author(s):  
Jay L Alberts ◽  
Joshua R Hirsch ◽  
Richard Figler ◽  
Andrew N Russman ◽  
Robert Gray ◽  
...  

2018 ◽  
Vol 35 (4) ◽  
pp. 691-694 ◽  
Author(s):  
Ross Mathiasen ◽  
Christopher Hogrefe ◽  
Kari Harland ◽  
Andrew Peterson ◽  
M. Kyle Smoot

PM&R ◽  
2011 ◽  
Vol 3 ◽  
pp. S188-S188
Author(s):  
Elena J. Jelsing ◽  
Jonathan Finnoff ◽  
John H. Hollman ◽  
Desiree J. Lanzino ◽  
Cara Prideaux ◽  
...  

CJEM ◽  
2018 ◽  
Vol 20 (S1) ◽  
pp. S100-S101
Author(s):  
A. Robert ◽  
M. Moroz ◽  
D. Var ◽  
J. Correa ◽  
S. Delaney

Introduction: During a hockey game, athletes who are suspected of having sustained a concussion are removed from the game and evaluated. The modified balance error scoring system (MBESS) assessment, an essential part of the concussion evaluation, is performed in the dressing room, barefoot on a hard surface after equipment removal. While, players that pass the concussion assessment may re-dress and return to play, the equipment removal and re-dressing delays their return into the game. The objective of our study was to develop and evaluate a new in-skates balance error scoring system (SBESS) to reduce the delay in returning to the game. Methods: A prospective randomized single blinded study was conducted with 80 healthy university hockey players split into two groups. An at-rest group performed the SBESS assessment at rest on two separate occasions. A post-exercise group performed the test once at rest and once after exercise. The SBESS consisted of performing 4 different stances for 20 seconds each without equipment removal. The assessments were video recorded, and 3 independent reviewers scored the videos. For both the at-rest and post-exercise groups, the primary outcome measured was the number of balance errors. The secondary outcome was the number of falls. Statistics: For the primary outcome, both inter-rater and intra-rater reliability were calculated. The concordance between the SBESS and the currently used baseline pre-season balance score (MBESS) was also assessed. Results: The number of cumulative balance errors for all four stances varied between 4 and 7 for both groups without any significant exercise effect. No athletes fell. For inter-rater reliability, the intra-class correlation (ICC) was above 0.86, ranging from 0.86-0.92 for most stances except for the easiest stance, for which it was 0.66. For intra-rater reliability, the ICC ranged from 0.88 to 1 for all stances and raters. There was a lack of concordance between the SBESS and MBESS. Conclusion: The SBESS is a reliable balance test that can be safely performed in healthy athletes wearing their full equipment. The next step will be to evaluate the use of this test on concussed hockey athletes


Sign in / Sign up

Export Citation Format

Share Document