scholarly journals Robot assisted versus Conventional Total Knee Arthroplasty: A prospective randomized controlled trial featuring long term follow-up

10.29007/cdct ◽  
2018 ◽  
Author(s):  
Eun-Kyoo Song ◽  
Jong-Keun Seon ◽  
Won-Gyun Lee

This study determined if robot assisted total knee arthroplasty (TKA) allows for more accurate alignment, better clinical outcome and long term survival rate compared with conventional TKA. 155 consecutive patients who underwent primary TKA were followed more than ten years. Robotic-assisted TKA appears to reduce the number of mechanical axis alignment outliers without any differences in clinical scores, complications and survival rates when compared to conventional manual techniques.

10.29007/3724 ◽  
2018 ◽  
Author(s):  
Eun-Kyoo Song ◽  
Jong-Keun Seon ◽  
Dong-Hyun Lee ◽  
Je-Hyoung Yeo

Total knee arthroplasty using navigation system is known to be more effective than conventional methods in achieving more accurate bone resection and neutral alignment.1 Mobile bearing is also known to reduce wear and automatically correct rotational malalignment of the tibia but the long-term follow-up results of more than 10 years are extremely rare.2, 3 The purpose of this study is to investigate the results of clinical and radiologic long-term follow-up and complications of total knee arthroplasty using navigation and multi-directional mobile bearing.From 2003 to 2006, a total of 111 navigation TKAs using multi-directional mobile bearing design were carried out and reviewed retrospectively. TKAs were performed by two experienced surgeons at one institute. Of the 111 patients, 102 were women and 9 were men. The mean duration of follow-up was 11.4 ± 1.0 years (range, 10.1 to 14.08 years). Clinical outcomes were evaluated in terms of Knee Society Score, Hospital for Special Surgery score, Western Ontario and McMaster University (WOMAC) score, range of motion and complications. Long-term radiological outcomes and survival rates were evaluated at least 10 years.Average preoperative HSS score was 66.5 ± 9.8 and KSS pain and function score were 25.0 ± 11.8 and 44.5 ± 12.3, respectively. Scores improved to 94.1 ± 8.2, 46.6 ± 11.6 and 88.2 ± 14.6 at the last follow up, respectively. Mean preoperative WOMAC scores of 75.8 ± 16.5 improved to 13.8 ± 16.0 at last follow-up. Five knees required re-operation, two for liner breakage, one for liner wear, one for distal femoral fracture and one for infection. The estimated 10-year prosthesis survival rates for any reason and for prosthesis-related problems were 95.5% and 97.4% , respectively.TKAs using each techniques resulted in similar good clinical outcomes and postoperative leg alignments. Robotic and navigation TKA appeared to reduce the number of postoperative leg alignment outliers and revision rate compared to conventional TKA.


2021 ◽  
Vol 103-B (1) ◽  
pp. 98-104 ◽  
Author(s):  
Bas van Ooij ◽  
Inger N. Sierevelt ◽  
Harm M. van der Vis ◽  
Daniël Hoornenborg ◽  
Daniël Haverkamp

Aims For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. Methods A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. Results RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. Conclusion Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98–104.


2013 ◽  
Vol 38 (4) ◽  
pp. 747-752 ◽  
Author(s):  
Matthias Bachmann ◽  
Lilianna Bolliger ◽  
Thomas Ilchmann ◽  
Martin Clauss

2021 ◽  
Vol 11 (4) ◽  
Author(s):  
Li Zong Xian ◽  
Andrew Tan Hwee Chye

Introduction: The cementless Oxford partial knee arthroplasty is associated with low perioperative complications and good long-term survival rates. However, perioperative fractures remain a serious morbidity for patients. Case Report: This case report describes an early post-operative tibial periprosthetic fracture through the keel slot, which we believe may be contributed by the deep implant keel design and the presence of a narrow metaphysis in the Asian knee. The patient subsequently underwent a revision total knee replacement and fixation of the periprosthetic fracture. Conclusion: This paper discusses the ways to identify patients at high risk of developing periprosthetic fractures and to minimize such occurrences, including adopting a modified tibial preparation, doing precise saw cuts, and considering a cemented tibial implant. Keywords: Cementless, Oxford, unicompartmental, periprosthetic, keel.


Coatings ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 442 ◽  
Author(s):  
Georg Hauer ◽  
Lukas Leitner ◽  
Marc C. Ackerl ◽  
Sebastian Klim ◽  
Ines Vielgut ◽  
...  

Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.


Sign in / Sign up

Export Citation Format

Share Document