Cathodic Protection System Retrofit to Extend Platform Service Life

2018 ◽  
Author(s):  
Sophia Kangan
Author(s):  
Jacob Brink Jansson ◽  
Ruth Sørensen ◽  
Kirsten Riis

Cathodic protection is a very well-known method of preventing or stopping reinforcement corrosion and thereby extending the service life of reinforced concrete civil structures. However, a number of factors, which among others are design, materials and components, installation methods, quality of workmanship, and operation and maintenance of the cathodic protection system, have influence on the functionality and effectivity of the cathodic protection system. The optimum design that fulfils the Client''s requirements to cost, traffic disruption, service life, etc. shall be determined in accordance with the structure layout and the ability of the Client''s organisation to conduct operation and maintenance. It is critical to ensure that all components are installed properly to achieve the expected service life of the system. Regular and correct operation and maintenance is also crucial to ensure the functionality and effectivity system.


1999 ◽  
Vol 36 (01) ◽  
pp. 11-21
Author(s):  
Miles Y. Kikuta

The reality that a smaller force must continue to meet heavy overseas commitments clearly indicates that high maintenance, manpower intensive, and costly repair processes must continue to be improved. One of the most significant maintenance problems identified by the Fleet was the continual and costly requirement to overhaul the coating system in seawater ballast tanks. This paper reports on the research conducted in conjunction with the Naval Sea Systems Command (NAVSEA) to develop a seawater ballast tank preservation protocol which extends the current 5 to 7 year coating service life to one that is expected to last 20 years. The approach to develop the new preservation protocol is discussed, the critical elements of the new preservation protocol are described, and methodologies for the design of sacrificial cathodic protection system for seawater ballast tanks and for the detection of surface contamination are provided.


Respuestas ◽  
2016 ◽  
Vol 21 (1) ◽  
pp. 45 ◽  
Author(s):  
Daniel Alejandro Rodríguez-Caro ◽  
Enrique Vera-López ◽  
Helver Mauricio Muñoz-Barajas

Antecedentes: La protección catódica por corriente impresa es uno de los métodos para prevenir la corrosión de tuberías o tanques, preservando el estado estructural y la integridad del material. Para que un sistema de protección catódica funcione correctamente debe existir un control sobre las variables eléctricas que intervienen en el proceso, es por ello que se hace necesario monitorear variables tales como (Voltaje, Corriente y Potencial de protección). Objetivo: De esta manera se desarrolla un sistema de adquisición y monitoreo de datos en tiempo real, con el propósito de aumentar la accesibilidad a las variables eléctricas y de esta forma mejorar el funcionamiento del sistema de protección catódica. Métodos: El sistema de monitoreo y análisis de la información se basa en el concepto de SHM (Structural Health Monitoring), el cual consta de; un sistema electrónico de adquisición y envío remoto de señales (micro controlador y sistema GSM de comunicaciones) y un sistema de visualización y análisis de la información en un sistema móvil (celular), usando un servidor web para ello. Teniendo en cuenta que la condición de integridad estructural del ducto está determinada por el correcto funcionamiento del rectificador. Resultados: se logró implementar un sistema de monitoreo y visualización remota de las variables principales de un sistema de protección catódica. Se desarrolló un algoritmo basado en el concepto de SHM, el cual permite correlacionar, generar tendencia y establecer criterios de funcionamiento del sistema de protección catódica que permiten establecer si el sistema está asegurando la integridad estructural del ducto de transporte de crudo. Conclusión: lo novedoso del presente trabajo consiste en mostrar el comportamiento en tiempo real de las variables necesarias para analizar si el ducto está siendo correctamente protegido y generar las alarmas e informes sobre protección catódica, lo cual es la base del concepto de SHM (Structural Health Monitoring).AbstractBackground: Cathodic protection by impressed current is one of the methods to prevent corrosion of pipes or tanks, preserving the structural state and integrity of the material. For a cathodic protection system to function properly there must to be a control over the electrical variables involved in the process, which is why it is necessary to monitor variables such as (voltage, current and potential protection). Objective: to develop a system of data acquisition and monitoring in real time, in order to increase accessibility to electrical variables and thus improve the operation of the cathodic protection system. Methods: The monitoring and information analysis system is based on the concept of SHM (Structural Health Monitoring), which consists of an electronic system for remote acquisition and sending of signals (micro controller and GSM communications system) and a system for visualization and analysis of information in a mobile system (cell) using a web server for it. Given that the condition of structural integrity of the pipeline is determined by the correct operation of the rectifier. Results: It was possible to implement a monitoring and remote viewing system of the main variables of a cathodic protection system. An algorithm based on the concept of SHM was developed, allowing to correlate, generate trend and establish performance criteria for the cathodic protection system which allows to establish whether the system is ensuring the structural integrity of the crude transportation pipeline. Conclusion: the novelty of this work is to show the realtime behavior of the variables needed to analyze whether the pipeline is being properly protected and generate alarms and reports regarding cathodic protection, which is based on the concept of SHM (Structural Health Monitoring).Palabras Clave: corriente, corrosión, Innovación, monitoreo, SHM (Structural Health Monitoring)


2020 ◽  
Vol 19 ◽  

Cathodic protection is defined as a method for slowing down or complete elimination of corrosion processes on underground or underwater, insulated or uninsulated metal structures. Protection by cathodic protection system is achieved by polarizing protected object to more negative value, with respect to its equilibrium potential. Design of the cathodic protection system implies determination of the electric potential and current density on the electrode surfaces after installation of the cathodic protection system. Most efficient way for determination of the electric potential and current density in the cathodic protection system is by applying numerical techniques. When modeling cathodic protection systems by numerical techniques, electrochemical reactions that occur on electrode surfaces are taken into account by polarization characteristics. Because of nature of the electrochemical reactions, polarization characteristics are nonlinear and under certain conditions can be time – varying (dynamic nonlinear polarization characteristics). This paper deals with numerical modeling of the cathodic protection system with dynamic nonlinear polarization characteristics. Numerical model presented in this paper is divided in the two parts. First part, which is based on the direct boundary element method, is used for the calculation of the distribution of electric potential and current density on the electrode surfaces in the spatial domain. Second part of the model is based on the finite difference time domain method and is used for the calculation of the electric potential and current density change over time. The use of presented numerical model is demonstrated on two simple geometrically examples.


Sign in / Sign up

Export Citation Format

Share Document