scholarly journals Rapid Determination of Low-level Sulfite in Dry Vegetables and Fruits by LC-ICP-MS

2015 ◽  
Vol 21 (1) ◽  
pp. 1-6 ◽  
Author(s):  
Zhanglin Ni ◽  
Fubin Tang ◽  
Yihua Liu ◽  
Danyu Shen ◽  
Runhong Mo
1994 ◽  
Vol 45 (2) ◽  
pp. 251-256 ◽  
Author(s):  
Chu-Fang Wang ◽  
Jeng-Horng Lee ◽  
Horng-Jye Chiou

2019 ◽  
Vol 34 (10) ◽  
pp. 2027-2034 ◽  
Author(s):  
Shan Xing ◽  
Maoyi Luo ◽  
Yang Wu ◽  
Daqian Liu ◽  
Xiongxin Dai

A rapid, novel and sensitive method was developed for the determination of uranium isotopes in CaF2 sludge by using lithium metaborate fusion and ICP-MS/MS under He mode. This technology could be useful for treatment of radionuclide contaminated nuclear industry waste.


2012 ◽  
Vol 36 (2) ◽  
pp. 131-148 ◽  
Author(s):  
Tatsuo Nozaki ◽  
Katsuhiko Suzuki ◽  
Gregory Ravizza ◽  
Jun-Ichi Kimura ◽  
Qing Chang

Chemosphere ◽  
2009 ◽  
Vol 75 (8) ◽  
pp. 1065-1073 ◽  
Author(s):  
Shinichi Miyashita ◽  
Masahito Shimoya ◽  
Yoshiaki Kamidate ◽  
Takayoshi Kuroiwa ◽  
Osamu Shikino ◽  
...  

2017 ◽  
Vol 485 ◽  
pp. 201-209 ◽  
Author(s):  
Stephen R. Durham ◽  
David P. Gillikin ◽  
David H. Goodwin ◽  
Gregory P. Dietl

2021 ◽  
Vol 245 ◽  
pp. 03004
Author(s):  
Yanxia Zeng ◽  
Xiashi Zhu

A subject for the rapid determination of iodine content in drinking water by isopropyl sensitization and ICP-MS was established. The samples were dissolved in 1% ammonia solution, 127I was selected as the mass number to be measured and 159Tb as an internal standard. At the same time, 4% (V/V) isopropanol was used to enhance aerosol gasification efficiency, 2% NH3·H2O was used to effectively eliminate memory effects of iodine by cleaning sample for 180 seconds. The results show that, the detection limits of iodine in this method are 0.007 mg·kg-1 and it is superior to other literature. The standard curve has a good linear relationship and the recovery rates of testing rusults range are from 96.00% to 112.3%. The content of iodine in standard substance water samples was determined by ICP-MS method. The iodine content in water samples from seven drinking water sources in Lianyungang area was analyzed between 14~21 μg·L-1. It was in line with the allowable value of 10~300 μg·L-1 of the sanitary standard for drinking water, suggesting that the iodine content of drinking water resources in Lianyungang area was in a safe range.


2020 ◽  
Vol 35 (8) ◽  
pp. 1566-1573
Author(s):  
Lan-Lan Tian ◽  
Ying-Zeng Gong ◽  
Wei Wei ◽  
Jin-Ting Kang ◽  
Hui-Min Yu ◽  
...  

This study presents a rapid and simple method of high precision Ba isotope measurement for barite using H2O extraction.


Sign in / Sign up

Export Citation Format

Share Document