Radiographic assessment of snap-shunt failure

2010 ◽  
Vol 6 (3) ◽  
pp. 299-302 ◽  
Author(s):  
Anand I. Rughani ◽  
Bruce I. Tranmer ◽  
Jeffrey E. Florman ◽  
James T. Wilson

Accurate assessment of imaging studies in patients with ventriculoperitoneal shunts can be aided by empirical findings. The authors characterize an objective measurement easily performed on head CT scans with the goal of producing clear evidence of shunt fracture or disconnection in patients with a snap shunt–type system. The authors describe 2 cases of ventriculoperitoneal shunt failure involving a fracture and a disconnection associated with a snap-shunt assembly. In both cases the initial clinical symptoms were not convincing for shunt malfunction, and the interpretation of the CT finding failed to immediately identify the abnormality. As the clinical picture became more convincing for shunt malfunction, each patient subsequently underwent successful shunt revision. The authors reviewed the CT scans of 10 patients with an intact and functioning snap-shunt system to characterize the normal appearance of the snap-shunt connection. On CT scans the distance between the radiopaque portion of the ventricular catheter and the radiopaque portion of the reservoir dome measures an average of 4.72 mm (range 4.6–4.9 mm, 95% CI 4.63–4.81 mm). In the authors' patient with a fractured ventricular catheter, this interval measured 7.8 mm, and in the patient with a disconnection it measured 7.7 mm. In comparison with the range of normal values, a radiolucent interval significantly greater than 4.9 mm should promptly raise concern for a disconnected or fractured shunt in this system. This measurement may prove particularly useful when serial imaging is not readily available.

1986 ◽  
Vol 64 (3) ◽  
pp. 386-389 ◽  
Author(s):  
Dennis L. Johnson ◽  
Charles Fitz ◽  
David C. McCullough ◽  
Saul Schwarz

✓ Death from cerebrospinal fluid shunt malfunction is a rare but tragic event. The authors describe seven children who when admitted were lethargic but arousable because of shunt failure. Sudden deterioration prompted unscheduled emergency shunt revision in each case. Two children subsequently died. Although neither the history nor the physical findings predicted this life-threatening shunt malfunction, obliteration of the perimesencephalic cistern was apparent on all preoperative computerized tomography (CT) scans. For reference, the scans of 43 other hydrocephalic children were drawn randomly from the hospital files and analyzed. It is concluded that CT evidence of obliteration of the perimesencephalic cistern is a useful warning of life-threatening shunt failure.


2019 ◽  
Vol 24 (6) ◽  
pp. 642-651
Author(s):  
Joyce Koueik ◽  
Mark R. Kraemer ◽  
David Hsu ◽  
Elias Rizk ◽  
Ryan Zea ◽  
...  

OBJECTIVERecent evidence points to gravity-dependent chronic shunt overdrainage as a significant, if not leading, cause of proximal shunt failure. Yet, shunt overdrainage or siphoning persists despite innovations in valve technology. The authors examined the effectiveness of adding resistance to flow in shunt systems via antisiphon devices (ASDs) in preventing proximal shunt obstruction.METHODSA retrospective observational cohort study was completed on patients who had an ASD (or additional valve) added to their shunt system between 2004 and 2016. Detailed clinical, radiographic, and surgical findings were examined. Shunt failure rates were compared before and after ASD addition.RESULTSSeventy-eight patients with shunted hydrocephalus were treated with placement of an ASD several centimeters distal to the primary valve. The records of 12 of these patients were analyzed separately due to a complex shunt revision history (i.e., > 10 lifetime shunt revisions). The authors found that adding an ASD decreased the 1-year ventricular catheter obstruction rates in the “simple” and “complex” groups by 67.3% and 75.8%, respectively, and the 5-year rates by 43.3% and 65.6%, respectively. The main long-term ASD complication was ASD removal for presumed valve pressure intolerance in 5 patients.CONCLUSIONSUsing an ASD may result in significant reductions in ventricular catheter shunt obstruction rates. If confirmed with prospective studies, this observation would lend further evidence that chronic shunt overdrainage is a central cause of shunt malfunction, and provide pilot data to establish clinical and laboratory studies that assess optimal ASD type, number, and position, and eventually develop shunt valve systems that are altogether resistant to siphoning.


2021 ◽  
Vol 3 (1(January-April)) ◽  
pp. e792021
Author(s):  
Bermans Iskandar ◽  
Ricardo de Amoreira Gepp

Objective:   Hydrocephalus is the most common neurological disease in pediatric neurosurgery.(1) The CSF shunts remains as the most common treatment choice for nonobstructive hydrocephalus worldwide, but shunt complications still the most common neurosurgical problem, especially in pediatric neurosurgery. Endoscopy and shunts are the way to treat hydrocephalus. Especially third ventriculostomy is the most effective treatment to obstructive hydrocephalus but shunt still the most important way to treat.(2, 3) Shunt malfunction is frequent and after so many years this is very important problem to the patients. Ventricular problem due to obstruction is responsible up to 72% of shunt problems.(4) The Shunt Trial Study showed that the overall shunt survival was 62% at 1 year, 52% at 2 years, 46% at 3 years, 41% at 4 years. The survival curves for the 3 differents valves were similar to those from the original trial and did not show a survival advantage for any particular valve.(5, 6) We still don´t have one perfect solution to hydrocephalus and shunt malfunction. The major author described his experience in use endoscopy to evaluate and treat shunt malfunction and one new approach and way to evaluate this problem.   Results/Discussion: The literature review was performed, and we found 84 articles when we used the keywords. Endoscopy has been one important way to treat and solve shunt problems. In obstructive hydrocephalus third ventriculostomy is the best way to treat these patients.(1-3) The major author first described goals of endoscopy. First goal is safe catheter removal in surgical review, avoiding bleeding when removing catheter addressing all the adhesions on catheter. Second goal is put in optimal position the new catheter with pure endoscopy view or using neuronavigation systems that could help the endoscope system.(7, 8)   Optimal new catheter placement and optimal long-term catheter survival are especially important because most of the problems are due to ventricular problems. These good placements could avoid loculations and ventricular collapse with ependymal problems. Avoid new catheter malpositiitioning, you can use the endoscope to follow the old tract to insert the new catheter in one good position avoiding choroid plexus. Another situation is when you have small ventricles especially in slit ventricle syndrome.   The major author has been studied some causes to ventricular catheter obstruction. He noticed after some surgical reviews some ventricular ependymal inside catheter. Ventricular ependymal protrusions inside the catheter could cause intermittent occlusion.(8) Some endoscope views showed these protrusion and ependymal changes after intermittent increase and decrease of ventricular pressure. These protrusions correspond to catheter holes a secondary to suction. These protrusions could stuck in the holes in chronicle suction.(8) The major author reported one endoscopic evidence of overdrainage-related ventricular tissue protrusions that cause partial or complete obstruction of the ventricular catheter. He did a retrospective review in fifty patients underwent 83 endoscopic shunt revision procedures that revealed in-growth of ventricular wall tissue into the catheter tip orifices (ependymal bands), producing partial, complete, or intermittent shunt obstructions. Endoscopic ventricular explorations revealed ependymal bands at various stages of development, which appear to form secondarily to siphoning.(8) How to minimize this overshunting? Anti siphon systems could help and decrease proximal shunt malfunction in some complex patients. The other problem is ventricular bleeding. The use of endoscope has been important tool to remove ventricular catheters, when you could see the adhesions.(9) The use the endoscope could be particularly important to open loculations and cysts avoiding ventricular entrapment. Patients with ventricular cysts could need more than one catheter. The use of endoscopy to fenestrate the cyst could keep the patient with one catheter or without any shunt system.(10, 11)   Conclusion: Shunt malfunction has a lot of possible causes, but a probably ventricular catheter problem is the most common situation. Choose appropriate endoscope rigid or flexible for each case could help to treat and avoid some of ventricular. Endoscopy could be one important tool to help the surgeon to understand and solve this dangerous situation to the patient. Ventricular wall protrusions are a significant cause of proximal shunt obstruction, and they appear to be caused by siphoning of surrounding tissue into the ventricular catheter orifices.


2007 ◽  
Vol 22 (4) ◽  
pp. 1-6 ◽  
Author(s):  
Romergryko G. Geocadin ◽  
Panayiotis N. Varelas ◽  
Daniele Rigamonti ◽  
Michael A. Williams

Object The authors attempted to determine whether continuous intracrnial pressure monitoring via the shunt resevoir identifies ventriculoperitoneal (VP) shunt malfunctions that are not identified by radionuclide shunt patency study or shunt tap in adults with hydrocephalus. Methods During a 2-year period, 26 adults underwent 32 in-hospital continuous intracranial pressure (ICP) monitoring evaluations via needle access of a shunt reservoir. Monitoring was performed for 26.8 ± 13.8 hours (mean ± standard deviation). No ICP waveform abnormality was detected in 31% of the evaluations (10 of 32). In contrast, abnormalities were detected in 69% (22 of 32 evaluations), including B waves (nine of 22 evaluations), siphoning (nine of 22 evaluations), and variable ICP (two of 22 evaluations). In 20 (91%) of these 22 evaluations, the ICP abnormality was detected only after continuous ICP monitoring; in the other two evaluations, ICP became abnormal immediately on accessing the shunt reservoir. On the basis of the ICP monitoring results, shunt revision was performed in 66% (21 of 32 evaluations) and medical therapy was administered in 34% (11 of 32 evaluations). Shunt revision led to symptom improvement in 82% (18 of 22 patients) and no change in 18% (four of 22 patients); medical therapy led to improvement in 18% (two of 11 patients), worsening in 18% (two of 11 patients), and no change in 64% (seven of 11 patients; p < 0.05). Conclusions Continuous ICP monitoring via the shunt reservoir provides a more accurate assessment of shunt malfunction than transient ICP monitoring with a shunt tap or a radionuclide shunt patency study. It is a safe method for evaluating patients with suspected VP shunt malfunction, provides in vivo assessment of the effect of the shunt system on a patient's ICP, and can lead to more effective shunt revision.


2013 ◽  
Vol 11 (6) ◽  
pp. 710-712 ◽  
Author(s):  
Amit Singla ◽  
Ning Lin ◽  
Allen L. Ho ◽  
R. Michael Scott ◽  
Edward R. Smith

Surgically created openings such as bur holes can serve as avenues for the development of collateral blood supply to the brain in patients with moyamoya disease. When such collateralization occurs through preexisting shunt catheter sites, the potential exists for perioperative stroke if these vessels are damaged during revision of a ventricular catheter for shunt malfunction. In this paper the authors report on a series of patients with a history of ventriculoperitoneal (VP) shunts who later developed moyamoya disease and were found to have spontaneous transdural collateral vessels at ventricular catheter sites readily visualized on diagnostic angiography. A consecutive surgical series of 412 patients with moyamoya disease treated at Boston Children's Hospital from 1990 to 2010 were reviewed to identify patients with concomitant moyamoya and a VP shunt. The clinical records and angiograms of these patients were reviewed to determine the extent of bur hole collaterals through the shunt site. Three patients were identified who had VP shunts placed for hydrocephalus and subsequently developed moyamoya disease. All 3 patients demonstrated spontaneous transdural collaterals at the ventricular catheter bur hole, as confirmed by angiography during the workup for moyamoya disease. No patients required subsequent revision of their ventricular catheters following the diagnosis of moyamoya. All patients have remained stroke free and clinically stable following pial synangiosis. Although the association of moyamoya and shunted hydrocephalus is rare, it may present a significant potential problem for the neurosurgeon treating a shunt malfunction in this patient population, because shunt bur holes may become entry sites for the ingrowth of significant cortical transdural collateral blood supply to the underlying brain. Shunt revision might therefore be associated with an increased risk of postoperative stroke or operative-site hemorrhage in this population if this vascularization is interrupted when shunt catheters are removed and replaced. A knowledge of the existence of shunt-related collaterals in patients with moyamoya may aid the surgeon in planning shunt revisions and considering, for example, a new entry point for a ventricular catheter, rather than replacing an existing one, to minimize the risk of jeopardizing existing collaterals.


2016 ◽  
Vol 17 (3) ◽  
pp. 249-259 ◽  
Author(s):  
Nicholas B. Rossi ◽  
Nickalus R. Khan ◽  
Tamekia L. Jones ◽  
Jacob Lepard ◽  
Joseph H. McAbee ◽  
...  

OBJECT Ventricular shunts for pediatric hydrocephalus continue to be plagued with high failure rates. Reported risk factors for shunt failure are inconsistent and controversial. The raw or global shunt revision rate has been the foundation of several proposed quality metrics. The authors undertook this study to determine risk factors for shunt revision within their own patient population. METHODS In this single-center retrospective cohort study, a database was created of all ventricular shunt operations performed at the authors’ institution from January 1, 2010, through December 2013. For each index shunt surgery, demographic, clinical, and procedural variables were assembled. An “index surgery” was defined as implantation of a new shunt or the revision or augmentation of an existing shunt system. Bivariate analyses were first performed to evaluate individual effects of each independent variable on shunt failure at 90 days and at 180 days. A final multivariate model was chosen for each outcome by using a backward model selection approach. RESULTS There were 466 patients in the study accounting for 739 unique (“index”) operations, for an average of 1.59 procedures per patient. The median age for the cohort at the time of the first shunt surgery was 5 years (range 0–35.7 years), with 53.9% males. The 90- and 180-day shunt failure rates were 24.1% and 29.9%, respectively. The authors found no variable—demographic, clinical, or procedural—that predicted shunt failure within 90 or 180 days. CONCLUSIONS In this study, none of the risk factors that were examined were statistically significant in determining shunt failure within 90 or 180 days. Given the negative findings and the fact that all other risk factors for shunt failure that have been proposed in the literature thus far are beyond the control of the surgeon (i.e., nonmodifiable), the use of an institution’s or individual’s global shunt revision rate remains questionable and needs further evaluation before being accepted as a quality metric.


Vascular ◽  
2013 ◽  
Vol 21 (5) ◽  
pp. 293-299 ◽  
Author(s):  
V Kazan ◽  
W Qu ◽  
M Al-Natour ◽  
J Abbas ◽  
M Nazzal

The aim of the paper is to determine the incidence of celiac artery compression (CAC) based on computed tomography (CT) scan and correlate the findings to the clinical presentation of patients presenting for CT scan in a hospital. Abdominal CT scans of patients were reviewed between September 2010 and November 2010. CAC was diagnosed if the celiac axis appeared to have a hook or U-shaped appearance with stenosis. The medical records of the patients were reviewed for gastrointestinal symptoms (abdominal pain, nausea, vomiting, constipation, diarrhea), as well as food fear and weight loss. Patients with CAC had lower incidence of symptoms compared with those without CAC (42.1 versus 65.3%, P = 0.042). A total of 450 patients were evaluated. In the end, 284 had both complete medical records and CT scans. The mean age for all patients was 51.3 ± 1.2 years. There were 124 men (42.6%) and 160 (57.4%) women. Nineteen (6.7%) patients had radiological evidence of CAC. CAC is not an uncommon CT finding in patients presenting for CT scan.


2012 ◽  
Vol 10 (4) ◽  
pp. 327-333 ◽  
Author(s):  
Elvis J. Hermann ◽  
Hans-Holger Capelle ◽  
Christoph A. Tschan ◽  
Joachim K. Krauss

Object Ventricular catheter shunt malfunction is the most common reason for shunt revision. Optimal ventricular catheter placement can be exceedingly difficult in patients with small ventricles or abnormal ventricular anatomy. Particularly in children and in premature infants with small head size, satisfactory positioning of the ventricular catheter can be a challenge. Navigation with electromagnetic tracking technology is an attractive and innovative therapeutic option. In this study, the authors demonstrate the advantages of using this technology for shunt placement in children. Methods Twenty-six children ranging in age from 4 days to 14 years (mean 3.8 years) with hydrocephalus and difficult ventricular anatomy or slit ventricles underwent electromagnetic-guided neuronavigated intraventricular catheter placement in a total of 29 procedures. Results The single-coil technology allows one to use flexible instruments, in this case the ventricular catheter stylet, to be tracked at the tip. Head movement during the operative procedure is possible without loss of navigation precision. The intraoperative catheter placement documented by screenshots correlated exactly with the position on the postoperative CT scan. There was no need for repeated ventricular punctures. There were no operative complications. Postoperatively, all children had accurate shunt placement. The overall shunt failure rate in our group was 15%, including 3 shunt infections (after 1 month, 5 months, and 10 months) requiring operative revision and 1 distal shunt failure. There were no proximal shunt malfunctions during follow-up (mean 23.5 months). Conclusions The electromagnetic-guided neuronavigation system enables safe and optimal catheter placement, especially in children and premature infants, alleviating the need for repeated cannulation attempts for ventricular puncture. In contrast to stereotactic techniques and conventional neuronavigation, there is no need for sharp head fixation using a Mayfield clamp. This technique may present the possibility of reducing proximal shunt failure rates and costs for hydrocephalus treatment in this age cohort.


2020 ◽  
Vol 26 (3) ◽  
pp. 247-254
Author(s):  
Zohreh Habibi ◽  
Mehdi Golpayegani ◽  
Bahar Ashjaei ◽  
Keyvan Tayebi Meybodi ◽  
Farideh Nejat

OBJECTIVEDistal catheter malfunction due to pseudocyst formation or intraabdominal adhesion is a significant problem, especially in pediatric patients who have limited sites for distal catheter insertion. In this study, the authors present a series of 12 patients with intractable distal shunt malfunctions due to peritoneal pseudocyst formation who underwent distal catheter replacement in the suprahepatic space to reduce the risk of distal catheter malfunction.METHODSTwelve consecutive patients with shunt malfunction due to pseudocyst formation who had undergone ventriculosuprahepatic shunting from 2014 to 2019 were identified. According to medical records, after primary evaluations, shunt removal, and antibiotic therapy, they underwent revision surgeries with placement of a distal catheter into the suprahepatic space.RESULTSNine boys and 3 girls, ranging in age from 5 months to 14 years, with one or more episodes of pseudocyst formation, underwent shunt revision with placement of a distal catheter into the suprahepatic space. After a median follow-up of 31 months, none of the patients experienced further distal malfunction.CONCLUSIONSThe suprahepatic space appears to be a safe place to secure the distal end of a ventricular catheter following pseudocyst formation, with less risk of re-adhesion. This lower risk might be attributable to the lack of omentum in the suprahepatic space.


2016 ◽  
Vol 41 (3) ◽  
pp. E10 ◽  
Author(s):  
Thomas J. Wilson ◽  
Kathleen E. McCoy ◽  
Wajd N. Al-Holou ◽  
Sergio L. Molina ◽  
Matthew D. Smyth ◽  
...  

OBJECTIVE The aim of this paper is to compare the accuracy of the freehand technique versus the use of intraoperative guidance (either ultrasound guidance or frameless stereotaxy) for placement of parietooccipital ventricular catheters and to determine factors associated with reduced proximal shunt failure. METHODS This retrospective cohort study included all patients from 2 institutions who underwent a ventricular cerebrospinal fluid (CSF) shunting procedure in which a new parietooccipital ventricular catheter was placed between January 2005 and December 2013. Data abstracted for each patient included age, sex, method of ventricular catheter placement, side of ventricular catheter placement, Evans ratio, and bifrontal ventricular span. Postoperative radiographic studies were reviewed for accuracy of ventricular catheter placement. Medical records were also reviewed for evidence of shunt failure requiring revision. Standard statistical methods were used for analysis. RESULTS A total of 257 patients were included in the study: 134 from the University of Michigan and 123 from Washington University in St. Louis. Accurate ventricular catheter placement was achieved in 81.2% of cases in which intraoperative guidance was used versus 67.3% when the freehand technique was used. Increasing age reduced the likelihood of accurate catheter placement (OR 0.983, 95% CI 0.971–0.995; p = 0.005), while the use of intraoperative guidance significantly increased the likelihood (OR 2.809, 95% CI 1.406–5.618; p = 0.016). During the study period, 108 patients (42.0%) experienced shunt failure, 79 patients (30.7%) had failure involving the proximal catheter, and 53 patients (20.6%) had distal failure (valve or distal catheter). Increasing age reduced the likelihood of being free from proximal shunt failure (OR 0.983, 95% CI 0.970–0.995; p = 0.008), while both the use of intraoperative guidance (OR 2.385, 95% CI 1.227–5.032; p = 0.011), and accurate ventricular catheter placement (OR 3.424, 95% CI 1.796–6.524; p = 0.009) increased the likelihood. CONCLUSIONS The use of intraoperative guidance during parietooccipital ventricular catheter placement as part of a CSF shunt system significantly increases the likelihood of accurate catheter placement and subsequently reduces the rate of proximal shunt failure.