shunt revision
Recently Published Documents


TOTAL DOCUMENTS

280
(FIVE YEARS 83)

H-INDEX

32
(FIVE YEARS 4)

2022 ◽  
Vol 7 (4) ◽  
pp. 266-274
Author(s):  
Divya K P ◽  
Ajith Cherian

A patient with known epilepsy who has had a single, habitual seizure and whose mental status has returned to baseline need not be transported to the emergency department (ED) unless other injuries require so, whereas a patient with no history of epilepsy who has returned to baseline following a seizure should be evaluated. The evaluation should include basic biochemical parameters, toxicology screening and a brain imaging. One should investigate circumstances that may have precipitated a seizure, such as alcohol withdrawal, stimulant use, or head injury. Risk of recurrence of seizures is more likely in those with a history of significant brain injury or infection. If the patient has a normal magnetic resonance imaging (MRI) and electroencephalograph (EEG), the likelihood of a second seizure is approximately 1 in 3; if either test result is abnormal, the chances are approximately 1 in 2; if both are abnormal, the probability rises to 2 in 3. Computed tomography (CT) scan head is very useful in the evaluation of first seizure in infants less than six months of age. The clinical characteristics predictive of an abnormal CT scan for patients presenting with seizures were age less than 6 months or age greater than 65 years, history of cysticercosis, altered mentation, closed head injury, recent cerebrospinal fluid (CSF) shunt revision, malignancy, neurocutaneous disorder and seizures with focal onset or duration longer than 15 minutes. MRI has been shown to be superior to CT for the detection of cerebral lesions associated with epilepsy.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Julia Pereira Muniz Pontes ◽  
Pedro Henrique Costa Ferreira-Pinto ◽  
Elington Lannes Simoes ◽  
Thaina Zanon Cruz ◽  
Jefferson Trivino Sanchez ◽  
...  

Background. Ventriculoperitoneal shunt (VPS) remains the main treatment for hydrocephalus. However, VPS revision surgery is very common. Here, we present a case in which the retained ventricular catheter was removed using the endoscopic monopolar instrument. Methods. We report a case of a 28-year-old female who presented with VPS obstruction. She had two previous shunt revision surgeries due to shunt obstruction. Eleven years after the last one, she presented an abdominal pseudocyst that indicated a total system removal. During VPS revision surgery, a retained ventricular catheter was observed. The endoscopic monopolar instrument was introduced into the retained catheter under direct view. Coagulations in a back-and-forth movement were applied to release inner catheter adhesions. After these steps, the catheter was removed, and a new one was placed through the same route. Results. The catheter was removed without complications, confirmed by the postoperative cranial computed tomography. The patient remained asymptomatic. Conclusion. The described technique was effective and avoided ventricular bleeding. Further studies are necessary to validate this method.


Author(s):  
MG Hamilton ◽  
C Ball ◽  
R Holubkov ◽  
G Urbaneja ◽  
A Isaacs

Background: Ventriculoperitoneal (VP) shunt failures in adult patients are common and subject patients to multiple surgeries and a decreased quality of life. A prospective cohort Shunt Outcomes Quality Improvement (ShOut-QI) initiative was implemented to reduce shunt failure incidence through neuronavigation-assisted proximal catheter insertion and laparoscopy-guided distal catheter anchoring over the liver dome to drain CSF away from the omentum. Methods: “Pre-ShOut” and “Post-ShOut” groups of patients included those with and without neuronavigation/laparoscopy, respectively for insertion of a new VP shunt. The primary outcome was shunt failure which was defined as any return to surgery for shunt revision as determined with a standardized clinical and radiology follow-up protocol. Results: 244 patients (97 Pre-ShOut, 147 Post-ShOut), mean age 73 years, were enrolled over a 7-year interval and observed for a mean duration of 4 years after shunt insertion. Neuronavigation improved proximal catheter placement accuracy by 20% (p<.001), and shunt failure occurred in 57% vs 23% in the Pre-ShOut and Post-ShOut groups, respectively (p=.008), representing a 53% relative risk reduction in the incidence of shunt failure. Conclusions: Adult shunt failure incidence may be significantly reduced by improving the accuracy of proximal catheter placement with neuronavigation and reducing the risk of distal catheter failure with laparoscopic-guided placement.


Author(s):  
Alexander F. C. Hulsbergen ◽  
Francesca Siddi ◽  
Malia McAvoy ◽  
Benjamin T. Lynch ◽  
Madeline B. Karsten ◽  
...  

OBJECTIVE Postoperative routine imaging is common after pediatric ventricular shunt revision, but the benefit of scanning in the absence of symptoms is questionable. In this study, the authors aimed to assess how often routine scanning results in a change in clinical management after shunt revision. METHODS The records of a large, tertiary pediatric hospital were retrospectively reviewed for all consecutive cases of pediatric shunt revision between July 2013 and July 2018. Postoperative imaging was classified as routine (i.e., in the absence of symptoms, complications, or other direct indications) or nonroutine. Reinterventions within 30 days were assessed in these groups. RESULTS Of 387 included shunt revisions performed in 232 patients, postoperative imaging was performed in 297 (77%), which was routine in 244 (63%) and nonroutine in 53 (14%). Ninety revisions (23%) underwent any shunt-related procedure after postoperative imaging, including shunt reprogramming (n = 35, 9%), shunt tap (n = 10, 3%), and a return to the operating room (OR; n = 58, 15%). Of the 244 cases receiving routine imaging, 241 did not undergo a change in clinical management solely based on routine imaging findings. The remaining 3 cases returned to the OR, accounting for 0.8% (95% CI 0.0%–1.7%) of all cases or 1.2% (95% CI 0.0%–2.6%) of cases that received routine imaging. Furthermore, 27 of 244 patients in this group returned to the OR for other reasons, namely complications (n = 12) or recurrent symptoms (n = 15); all arose after initial routine imaging. CONCLUSIONS The authors found a low yield to routine imaging after pediatric shunt revision, with only 0.8% of cases undergoing a change in management based on routine imaging findings without corresponding clinical findings. Moreover, routine imaging without abnormal findings was no guarantee of an uneventful postoperative course. Clinical monitoring can be considered as an alternative in asymptomatic, uncomplicated patients.


2021 ◽  
Vol 2 (17) ◽  
Author(s):  
Lacey M. Carter ◽  
Alejandro Ruiz-Elizalde ◽  
Naina L. Gross

BACKGROUND When ventriculoperitoneal (VP) shunts and umbilical hernias coexist in the same patient, unique complications can occur. Typically, these are readily identified problems such as cerebrospinal fluid (CSF) fistulas or entrapment of the peritoneal catheter in the hernia. The authors present cases of two children whose VP shunt dysfunction resolved after repair of their umbilical hernias. OBSERVATIONS The authors present two cases of infant patients with shunted hydrocephalus and umbilical hernias. In both cases, the patients presented with distal shunt malfunctions not due to infection. Their shunt function improved once the umbilical hernia was repaired by pediatric surgery. Neither has required shunt revision since umbilical hernia repair. LESSONS Although there are case reports of VP shunts eroding through the umbilicus, developing CSF fistulas, or becoming trapped inside umbilical hernias, there is no case of VP shunt dysfunction caused by just the presence of an umbilical hernia. The authors suspect that the catheter may intermittently enter and exit the hernia. This may cause intermittent obstruction of the distal catheter, or inflammation in the hernia may occur that limits CSF absorption.


2021 ◽  
Vol 3 (10) ◽  
Author(s):  
Adarsh Manuel ◽  
Akarsh Jayachandran ◽  
Srinivasan Harish ◽  
Thenozhi Sunil ◽  
Vishnu Das K. R. ◽  
...  

Stenotrophomonas maltophilia is an extremely rare pathogen responsible for ventriculoperitoneal shunt infection and meningitis. This young female patient with history of multiple shunt revisions in the past, came to us with shunt dysfunction and exposure of the ventriculoperitoneal shunt tube in the neck. The abdominal end of the shunt tube was seen migrating into the bowel during shunt revision. The cerebrospinal fluid analysis showed evidence of Stenotrophomonas maltophilia growth. This is the first reported case of Stenotrophomonas maltophilia meningitis associated with ventriculoperitoneal shunt migration into the bowel.


Author(s):  
Mohammed Ali Alvi ◽  
Archis R. Bhandarkar ◽  
David J. Daniels ◽  
Kai J. Miller ◽  
Edward S. Ahn

OBJECTIVE CSF shunt insertion is the most commonly performed neurosurgical procedure for pediatric patients with hydrocephalus, and complications including infections and catheter obstruction are common. The rate of readmission in the first 30 days after surgery has been used across surgical disciplines to determine healthcare quality. In the current study, the authors sought to assess factors associated with early shunt revision within 30 days using real-world data. METHODS Targeted shunt data set participant user files of the National Surgical Quality Improvement Program (NSQIP) from 2016 to 2019 were queried for patients undergoing a shunt procedure. A multivariable logistic regression model was performed to assess the impact of demographics, etiologies, comorbidities, congenital malformations, and shunt adjuncts on shunt revision within 30 days, as well as shunt revision due to infection within 30 days. RESULTS A total of 3919 primary pediatric shunt insertions were identified in the NSQIP database, with a mean (± SD) patient age of 26.3 ± 51.6 months. There were a total of 285 (7.3%) unplanned shunt revisions within 30 days, with a mean duration of 14.9 ± 8.5 days to first intervention. The most common reason for intervention was mechanical shunt failure (32.6% of revision, 2.4% overall, n = 93), followed by infection (31.2% of all interventions, 2.3% overall, n = 89) and wound disruption or CSF leak (22.1% of all interventions, 1.6% overall, n = 63). Patients younger than 6 months of age had the highest overall unplanned 30-day revision rate (8.5%, 203/2402) as well as the highest 30-day shunt infection rate (3%, 72/2402). Patients who required a revision were also more likely to have a cardiac risk factor (34.7%, n = 99, vs 29.2%, n = 1061; p = 0.048). Multivariable logistic regression revealed that compared to patients 9–18 years old, those aged 2–9 years had significantly lower odds of repeat shunt intervention (p = 0.047), while certain etiologies including congenital hydrocephalus (p = 0.0127), intraventricular hemorrhage (IVH) of prematurity (p = 0.0173), neoplasm (p = 0.0005), infection (p = 0.0004), and syndromic etiology (p = 0.0136), as well as presence of ostomy (p = 0.0095), were associated with higher odds of repeat intervention. For shunt infection, IVH of prematurity was found to be associated with significantly higher odds (p = 0.0427) of shunt infection within 30 days, while use of intraventricular antibiotics was associated with significantly lower odds (p = 0.0085). CONCLUSIONS In this study of outcomes after pediatric shunt placement using a nationally derived cohort, early shunt failure and infection within 30 days were found to remain as considerable risks. The analysis of this national surgical quality registry confirms that, in accordance with other multicenter studies, hydrocephalus etiology, age, and presence of ostomy are important predictors of the need for early shunt revision. IVH of prematurity is associated with early infections while intraventricular antibiotics may be protective. These findings could be used for benchmarking in hospital efforts to improve quality of care for pediatric patients with hydrocephalus.


2021 ◽  
pp. 1-6
Author(s):  
Luke Galloway ◽  
Kishan Karia ◽  
Anwen M. White ◽  
Marian E. Byrne ◽  
Alexandra J. Sinclair ◽  
...  

OBJECTIVE Cerebrospinal fluid (CSF) shunting in idiopathic intracranial hypertension (IIH) is associated with high complication rates, primarily because of the technical challenges that are related to small ventricles and a large body habitus. In this study, the authors report the benefits of a standardized protocol for CSF shunting in patients with IIH as relates to shunt revisions. METHODS This was a retrospective study of consecutive patients with IIH who had undergone primary insertion of a CSF shunt between January 2014 and December 2020 at the authors’ hospital. In July 2019, they implemented a surgical protocol for shunting in IIH. This protocol recommended IIH shunt insertion by neurosurgeons with expertise in CSF disorders, a frontal ventriculoperitoneal (VP) shunt with an adjustable gravitational valve and integrated intracranial pressure monitoring device, frameless stereotactic insertion of the ventricular catheter, and laparoscopic insertion of the peritoneal catheter. Thirty-day revision rates before and after implementation of the protocol were compared in order to assess the impact of standardizing shunting for IIH on shunt complications. RESULTS The 81 patients included in the study were predominantly female (93%), with a mean age of 31 years at primary surgery and mean body mass index (BMI) of 37 kg/m2. Forty-five patients underwent primary surgery prior to implementation of the protocol and 36 patients after. Overall, 12 (15%) of 81 patients needed CSF shunt revision in the first 30 days, 10 before and 2 after introduction of the protocol. This represented a significant reduction in the early revision rate from 22% to 6% after the protocol (p = 0.036). The most common cause of shunt revision for the whole cohort was migration or misplacement of the peritoneal catheter, occurring in 6 of the 12 patients. Patients with a higher BMI were significantly more likely to have a shunt revision within 30 days (p = 0.022). CONCLUSIONS The Birmingham standardized IIH shunt protocol resulted in a significant reduction in revisions within 30 days of primary shunt surgery in patients with IIH. The authors recommend standardization for shunting in IIH as a method for improving surgical outcomes. They support the notion of subspecialization for IIH shunts, the use of a frontal VP shunt with sophisticated technology, and laparoscopic insertion of the peritoneal end.


Author(s):  
Rebecca A. Reynolds ◽  
Ranbir Ahluwalia ◽  
Vishal Krishnan ◽  
Katherine A. Kelly ◽  
Jaclyn Lee ◽  
...  

OBJECTIVE Children whose ventricles do not change during shunt malfunction present a diagnostic dilemma. This study was performed to identify risk factors for unchanged ventricular size at shunt malfunction. METHODS This retrospective 1:1 age-matched case-control study identified children with shunted hydrocephalus who underwent shunt revision with intraoperative evidence of malfunction at one of the three participating institutions from 1997 to 2019. Cases were defined as patients with a change of < 0.05 in the frontal–occipital horn ratio (FOR) between malfunction and baseline, and controls included patients with FOR changes ≥ 0.05. The presence of infection, abdominal pseudocyst, pseudomeningocele, or wound drainage and lack of baseline cranial imaging at the time of malfunction warranted exclusion. RESULTS Of 450 included patients, 60% were male, 73% were Caucasian, and 67% had an occipital shunt. The median age was 4.3 (IQR 0.97–9.21) years at malfunction. On univariable analysis, unchanged ventricles at malfunction were associated with a frontal shunt (41% vs 28%, p < 0.001), programmable valve (17% vs 9%, p = 0.011), nonsiphoning shunt (85% vs 66%, p < 0.001), larger baseline FOR (0.44 ± 0.12 vs 0.38 ± 0.11, p < 0.001), no prior shunt infection (87% vs 76%, p = 0.003), and no prior shunt revisions (68% vs 52%, p < 0.001). On multivariable analysis with collinear variables removed, patients with a frontal shunt (OR 1.67, 95% CI 1.08–2.70, p = 0.037), programmable valve (OR 2.63, 95% CI 1.32–5.26, p = 0.007), nonsiphoning shunt at malfunction (OR 2.76, 95% CI 1.63–4.67, p < 0.001), larger baseline FOR (OR 3.13, 95% CI 2.21–4.43, p < 0.001), and no prior shunt infection (OR 2.34, 95% CI 1.27–4.30, p = 0.007) were more likely to have unchanged ventricles at malfunction. CONCLUSIONS In a multicenter cohort of children with shunt malfunction, those with a frontal shunt, programmable valve, nonsiphoning shunt, baseline large ventricles, and no prior shunt infection were more likely than others to have unchanged ventricles at shunt failure.


2021 ◽  
Vol 12 ◽  
pp. 419
Author(s):  
Muhammad Azzam ◽  
Roidah Taqiyya Zahra Wathoni ◽  
Wihasto Suryaningtyas ◽  
Muhammad Arifin Parenrengi

Background: Hydrocephalus is a common problem in neurosurgery with shunt placement remains the mainstay of the management. However, shunt placement generally requires following surgical procedures, including shunt revision. Despite the recent developments, the incidence of shunt failure remains high, approximately 30–51% in the 1st year following the shunt placement. Methods: An observational retrospective study of pediatric neurosurgery patients whom underwent CSF shunting procedure, both primary and repeated VPS, VAS, CPS, and subdural-peritoneal shunt procedures between January 2018 and May 2019. The patients were observed for 12 months for potential complication requiring shunt revision following the shunt placement. Results: A total of 142 patients underwent shunt placement. The shunt revision within 12 months was found in 26 patients (18.3%), 25 cases were VPS (96.2%) and one case was CPS (3.8%). The mean period of time between shunt placement to shunt revision was 3.96 months. Age of under 6 months old during the shunt placement showed significantly higher risk for shunt revision (RR 2.32 CI 1.13–4.74, P = 0.018). The most common diagnosis requiring shunt revision was congenital anomaly (16 cases, 61.5%). The most common cause of revision was shunt malfunction, with 21 cases (80.8%) followed by infected shunt with 5 cases (19.2%). Conclusion: The 1st year observation showed relatively high rate for shunt revision. The patient underwent shunt procedure should be regularly followed up in long period for better evaluation of the outcome. The application of shunt registry in some countries appears to be efficient and beneficial for sustainable follow-up in patients underwent shunt placement.