cordis corporation
Recently Published Documents


TOTAL DOCUMENTS

7
(FIVE YEARS 1)

H-INDEX

3
(FIVE YEARS 0)

2021 ◽  
Vol 9 ◽  
pp. 2050313X2110145
Author(s):  
Yoshimitsu Soga ◽  
Kenji Ando

Restenosis after stent implantation in femoropopliteal lesions is still big issue. However, restenosis has been reduced by the recent new drug-eluting stent “Eluvia” (Boston Scientific, Marlborough, MA, USA). However, it was reported that “low echoic area (LEA)” finding around stent by ultrasound that they called “aneurysmal degeneration,” but no blood flow was identified outside the stent was confirmed after Eluvia implantation. In this report, we describe the similar findings that were observed after other types of stents (S.M.A.R.T. bare-nitinol stent (Cordis Corporation, Hialeah, FL, USA), Zilver PTX drug-coated stent (Cook Medical, Bloomington, IN, USA), and Viabahn stent graft (W. L. Gore & Associates, Newark, Delaware, USA)) for superficial femoral artery disease. These findings did not change to “aneurysmal change” during the follow-up.


Neurosurgery ◽  
2009 ◽  
Vol 65 (5) ◽  
pp. E1007-E1008 ◽  
Author(s):  
Demetrius K. Lopes ◽  
Kalani Wells

Abstract OBJECTIVE To describe a novel stent remodeling technique for the coiling of ruptured wide-neck cerebral aneurysms. CLINICAL PRESENTATION A 46-year-old man presented with acute subarachnoid hemorrhage (Hunt and Hess grade IV), intracerebral hemorrhage, and hydrocephalus. Cerebral angiography revealed a wide-neck small anterior communicating artery aneurysm. Conventional coiling was not successful because of coil instability and compromise of the dominant anterior cerebral artery. TECHNIQUE A 6-French shuttle sheath (Cook Medical, Indianapolis, IN) was advanced from a right femoral approach into the right common carotid artery. To protect the parent vessel during coiling without compromising blood flow, a Prowler Select Plus catheter (Cordis Corporation, Bridgewater, NJ) was navigated across the aneurysm neck. Subsequently, an Enterprise stent (22-mm length; Cordis Corporation) was partially deployed across the aneurysm's wide neck. It was very important to watch the distal markers of the stent and lock the stent delivery wire to the Prowler Select Plus with a hemostatic valve once the stent was halfway deployed. This maneuver was essential to prevent further deployment of the stent. The SL-10 microcatheter and Synchro 14 wire (Boston Scientific, Natick, MA) were carefully navigated to the aneurysm passing through the partially deployed stent. Coils were then delivered to the aneurysm using the stent as a scaffold. After coiling, the SL-10 microcatheter was removed and the stent was recaptured into the Prowler Select Plus catheter. During the recapture, there was initial resistance. This was easily overcome after deploying the stent a little more before resheathing. During the procedure, the patient received 2000 U of heparin after the first coil was detached in the aneurysm. CONCLUSION The stent remodeling technique is a novel endovascular technique that can be used to treat ruptured wide-neck aneurysms and maintain patency of parent vessels, avoiding the use of antiplatelet therapy in acute subarachnoid hemorrhage.


Sign in / Sign up

Export Citation Format

Share Document