Reliability and Agreement of 2D and 3D Measurements on MRAs for Growth Assessment of Unruptured Intracranial Aneurysms

Author(s):  
K.M. Timmins ◽  
H.J. Kuijf ◽  
M.D.I. Vergouwen ◽  
M.J. Otten ◽  
Y.M. Ruigrok ◽  
...  
2019 ◽  
Author(s):  
Khodayar Goshtasbi ◽  
Ronald Sahyouni ◽  
Alice Wang ◽  
Edward Choi ◽  
Gilbert Cadena ◽  
...  

2019 ◽  
Vol 24 (2) ◽  
pp. 184-189 ◽  
Author(s):  
Daniel-Alexandre Bisson ◽  
Peter Dirks ◽  
Afsaneh Amirabadi ◽  
Manohar M. Shroff ◽  
Timo Krings ◽  
...  

OBJECTIVEThere are little data in the literature on the characteristics and natural history of unruptured intracranial aneurysms in children. The authors analyzed their experience with unruptured intracranial aneurysms in the pediatric population at their tertiary care pediatric institution over the last 18 years. The first objective was to assess the imaging characteristics and natural history of these aneurysms in order to help guide management strategies in the future. A second objective was to evaluate the frequency of an underlying condition when an incidental intracranial aneurysm was detected in a child.METHODSThe authors conducted a Research Ethics Board–approved retrospective review of incidental intracranial aneurysms in patients younger than 18 years of age who had been treated at their institution in the period from 1998 to 2016. Clinical (age, sex, syndrome) and radiological (aneurysm location, type, size, thrombus, mass effect) data were recorded. Follow-up imaging was assessed for temporal changes.RESULTSSixty intracranial aneurysms occurred in 51 patients (36 males, 15 females) with a mean age of 10.5 ± 0.5 years (range 9 months–17 years). Forty-five patients (88.2%) had a single aneurysm, while 2 and 3 aneurysms were found in 3 patients each (5.8%). Syndromic association was found in 22 patients (43.1%), most frequently sickle cell disease (10/22 [45.5%]). Aneurysms were saccular in 43 cases (71.7%; mean size 5.0 ± 5.7 mm) and fusiform in the remaining 17 (28.3%; mean size 6.5 ± 2.7 mm). Thirty-one aneurysms (51.7%) arose from the internal carotid artery (right/left 1.4), most commonly in the cavernous segment (10/31 [32.3%]). Mean size change over the entire follow-up of 109 patient-years was a decrease of 0.6 ± 4.2 mm (range −30.0 to +4.0 mm, rate −0.12 ± 9.9 mm/yr). Interval growth (2.0 ± 1.0 mm) was seen in 8 aneurysms (13.3%; 4 saccular, 4 fusiform). An interval decrease in size (8.3 ± 10.7 mm) was seen in 6 aneurysms (10%). There was an inverse relationship between aneurysm size and growth rate (r = −0.82, p < 0.00001). One aneurysm was treated endovascularly with internal carotid artery sacrifice.CONCLUSIONSUnruptured pediatric intracranial aneurysms are most frequently single but can occur in multiples in a syndromic setting. None of the cases from the study period showed clinical or imaging signs of rupture. Growth over time, although unusual and slow, can occur in a proportion of these patients, who should be identified for short-term imaging surveillance.


2020 ◽  
Vol 9 (9) ◽  
pp. 2808
Author(s):  
Wojciech Poncyljusz ◽  
Kinga Kubiak ◽  
Leszek Sagan ◽  
Bartosz Limanówka ◽  
Katarzyna Kołaczyk

Background: Stent-assisted coiling is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new Accero stent for the treatment of intracranial aneurysms. Materials and Methods: It was a retrospective, single-center study. Eighteen unruptured intracranial aneurysms were treated using the stent-assisted coiling method with the Accero stent. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical results were analyzed. Follow-up magnetic resonance (MR) was performed 6 months after intervention. Results: Seventeen patients with 18 incidental unruptured aneurysms were electively treated with coiling and the Accero stent. The aneurysms were located on internal carotid artery (ICA), middle cerebral artery (MCA) and basilar artery (BA). All stents were deployed successfully. Immediate complete occlusion rate Raymond-Roy occlusion classification (RROC) class I was achieved in 13 cases and class II in 4 cases. Complications occurred in 2/17 treatments and included guidewire stent perforation with subarachnoid hemorrhage (SAH) and stent deformation. Vascular spasm in the subarachnoid hemorrhage (SAH) patient subsided before discharge. Ninety days after intervention, the modified Rankin Scale (mRS) value was 0. RROC class I was observed in 88.23% of cases in follow-up. Conclusion: The Accero stent provides excellent support for coil mass. It constitutes an efficacious device with good initial occlusion rate for treating wide-necked unruptured intracranial aneurysms.


2021 ◽  
pp. 159101992110259
Author(s):  
Kainaat Javed ◽  
Santiago R Unda ◽  
Ryan Holland ◽  
Adisson Fortunel ◽  
Rose Fluss ◽  
...  

Introduction Flow diversion is an effective treatment modality for intracranial aneurysms but is associated with ischemic and hemorrhagic complications. Patients treated with flow diversion require dual antiplatelet therapy and subsequent platelet function tests. At our institution, Thromboelastography with Platelet Mapping (TEG-PM) is the test of choice. The primary objective of this study was to identify TEG parameters that are predictive of postoperative complications in patients treated with elective flow diversion. Methods This was a retrospective study of 118 patients with unruptured intracranial aneurysms treated with flow diversion. Data was collected via chart review. Bivariate analyses were performed to identify significant variables in patients who suffered an ischemic stroke or a groin hematoma. ROC curves were constructed for the TEG parameters with statistical significance. Bivariate analyses were repeated using dichotomized TEG results. Results Patients who experienced a symptomatic ischemic stroke had a history of stroke (p value = 0.007), larger aneurysm neck width (p value = 0.017), and a higher alpha angle (p value = 0.013). Cut off point for ischemic complication is 63° on ROC curve with a sensitivity of 100% and specificity of 65%. Patients who experienced a groin hematoma were no different from their healthy peers but had a lower alpha angle (p value = 0.033). Cut off point for hemorrhagic complication is 53.3° with a sensitivity of 82% and specificity of 67%. Conclusion The Alpha Angle parameter of TEG-PM has a sizeable predictive ability for both ischemic complications of the central nervous system and hemorrhagic complications of the access site after elective flow diversion.


Author(s):  
Felipe Gomes de Barros Pontes ◽  
Edina MK da Silva ◽  
Jose CC Baptista-Silva ◽  
Vladimir Vasconcelos

2021 ◽  
pp. 197140092110269
Author(s):  
Kenji Yatomi ◽  
Yumiko Mitome-Mishima ◽  
Takashi Fujii ◽  
Kohsuke Teranishi ◽  
Hidenori Oishi ◽  
...  

Purpose Among all stents available for neuroendovascular therapy, the low-profile visible intraluminal support stent bears the highest metal coverage ratio. We deployed a low-profile visible intraluminal support stent with a delivery wire or/and microcatheter system push action to shorten the low-profile visible intraluminal support stent and thus achieve a flow diversion effect. We report our single-institution experience with the use of low-profile visible intraluminal support stents for intentionally shortened deployment (shortening group) and non-shortened deployment (non-shortening group) for unruptured intracranial aneurysms. Methods We retrospectively reviewed the medical records of 130 patients with 131 intracranial aneurysms who were treated with low-profile visible intraluminal support stent-assisted coil embolization from February 2016–January 2019. All perioperative complications were noted. Every 6 months, we re-examined the patients with cerebral angiography or magnetic resonance angiography. The outcomes of aneurysm occlusion were evaluated by the modified Raymond–Roy occlusion classification. We used the finite element method and computational fluid dynamics to investigate the hemodynamics after shortened low-profile visible intraluminal support stent deployment. Results Immediately after treatment, the modified Raymond-Roy occlusion classification was significantly better in the shortening group than in the non-shortening group ( p<0.05). The latest angiographic outcomes showed the same tendency. Hemodynamic analysis by computational fluid dynamics suggested an adequate flow diversion effect with the use of our intentional shortening method. Conclusions Stent-assisted coil embolization using this technique showed good results of a high complete occlusion rate and low complication rate. These findings suggest that shortened low-profile visible intraluminal support stent deployment yields a flow diversion effect and may lead to early intra-aneurysmal thrombus formation.


NeuroImage ◽  
2021 ◽  
pp. 118216
Author(s):  
Kimberley M. Timmins ◽  
Irene C. van der Schaaf ◽  
Edwin Bennink ◽  
Ynte M. Ruigrok ◽  
Xingle An ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document