Objective: We have developed a “stability-indicating RP-HPLC” procedure for the Bilastine (BLS) and montelukast (MTL) analysis of tablets. Methods: The quantification of BLS and MTL combination was implemented utilising a Waters column (C18, 5 μm, 250 mm and 4.6 mm). Isocratic mobile phase had 60% volume KH2PO4 of 0.1M strength with pH 4.2 units and 40% volume methanol at a flow with 1.0 ml/min speed. UV detection at 232 nm was done to examine BLS and MTL. Stability experiments of BLS and MTL under distinctive environments of stress were also performed. Results: The BLS and MTL were eluted at 1.810 min and 2.551 min, respectively. The responses were found to be linear for the concentration ranges of 10-30 µg/ml (BLS) and 5-15 µg/ml (MTL). Percent comparative standard deviance for precision was 0.331% (BLS) and 0.486% (MTL). Percent assay for accuracy was 98.96% (BLS) and 99.00% (MTL). The detection limit and quantitation limit measures for BLS were 0.018 µg/ml and 0.059 µg/ml, respectively, while for MTL it was 0.024 µg/ml and 0.081 µg/ml, respectively. Robustness studies authorized that the method is robust with percent comparative standard deviance of a highest 1.950%. Conclusion: The developed “stability-indicating RP-HPLC” procedure for the BLS and MTL analysis is simple, sensitive, precise, specific and robust, making it appropriate to the assessment of BLS and MTL in a tablet formulation.


Author(s):  
Sagar B. Wankhede ◽  
Deepak S. Khobragade ◽  
Sukeshini B. Lote ◽  
S. Patil

A combined dose tablet formulation containing Amlodipine besylate and Lisinopril is used for the treatment of essential hypertension. The present study reports development and validation of stability indicating high performance thin layer chromatographic method for simultaneous estimation of these drugs in combined dose tablet formulation. The two drugs were satisfactorily resolved on aluminum plates precoated with silica gel 60F254 using n-butanol : methanol: ammonia (4:4:1 v/v/v) as mobile phase. The Rf value for lisinopril and amlodipine besylate were 0.27±0.02 and 0.62±0.02, respectively. Densitometric evaluation of the separated bands was performed at 215nm. The calibration curves for lisinopril and amlodipine besylate were found to be linear in the concentration range of 1000-6000ng/band. The method was validated as per ICH guidelines for accuracy, precision, robustness, specificity, limit of detection and limit of quantitation. Statistical analysis proves that the method is suitable for simultaneous analysis of Lisinopril and Amlodipine besylate in pharmaceutical formulation without any interference from the excipients/degradant. The developed method offers several advantages such as sensitive, rapid, cost effective and less time consuming as compared to the reported methods. As the method could effectively separate the drugs from its degradation products, it can be employed as a stability indicating method.


Sign in / Sign up

Export Citation Format

Share Document