scholarly journals Force Analysis of Human Lumbar Spine Using a Forward Kinematics Model

2021 ◽  
Author(s):  
Krunal Patel

The purpose of this study is to present a forward kinematics model of the human lumbar spine and to compare the internal loads and trunk flexion extension with existing literature. The forward kinematics model of lumbar spine with 30 DOF was designed using Solidworks and used Matlab to simulate the results for different postures. The forward kinematics model predicted similar trend for trunk flexion extension, compression force, shear forces and moment as described in literature for in vivo studies. The comparison between the proposed model and in vivo measurement showed a pressure difference of less than 15% on the disc L4-L5 for all activities whereas the compression force and moment differed by ~17% on the disc L5-S1. The modeling methodology presented in this thesis provides a more accurate representation of compression forces and moments of the human lumbar spine since the model makes no assumptions regarding muscle force and does not rely on any other software for kinematics data.

2021 ◽  
Author(s):  
Krunal Patel

The purpose of this study is to present a forward kinematics model of the human lumbar spine and to compare the internal loads and trunk flexion extension with existing literature. The forward kinematics model of lumbar spine with 30 DOF was designed using Solidworks and used Matlab to simulate the results for different postures. The forward kinematics model predicted similar trend for trunk flexion extension, compression force, shear forces and moment as described in literature for in vivo studies. The comparison between the proposed model and in vivo measurement showed a pressure difference of less than 15% on the disc L4-L5 for all activities whereas the compression force and moment differed by ~17% on the disc L5-S1. The modeling methodology presented in this thesis provides a more accurate representation of compression forces and moments of the human lumbar spine since the model makes no assumptions regarding muscle force and does not rely on any other software for kinematics data.


Author(s):  
Ernur Karadogan ◽  
Robert L. Williams

This paper presents the kinematic and pseudostatic analyses of a fully cable-actuated robotic lumbar spine (RLS) which can mimic in vivo human lumbar spine movements to provide better hands-on training for medical students. The design incorporates five active lumbar vertebrae between the first lumbar vertebra and the sacrum, with dimensions of an average adult human spine. Medical schools can benefit from a tool, system, or method that will help instructors train students and assess their tactile proficiency throughout their education. The robotic lumbar spine has the potential to satisfy these needs in palpatory diagnosis. Medical students will be given the opportunity to examine their own patient that can be programmed with many dysfunctions related to the lumbar spine before they start their professional lives as doctors. The robotic lumbar spine can be used to teach and test medical students in their capacity to be able to recognize normal and abnormal movement patterns of the human lumbar spine under flexion-extension and lateral bending. This project focus is on palpation, but the spine robot could also benefit surgery training/planning and other related biomedical applications.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Ernur Karadogan ◽  
Robert L. Williams

The robotic lumbar spine (RLS) is a 15 degree-of-freedom, fully cable-actuated robotic lumbar spine which can mimicin vivohuman lumbar spine movements to provide better hands-on training for medical students. The design incorporates five active lumbar vertebrae and the sacrum, with dimensions of an average adult human spine. It is actuated by 20 cables connected to electric motors. Every vertebra is connected to the neighboring vertebrae by spherical joints. Medical schools can benefit from a tool, system, or method that will help instructors train students and assess their tactile proficiency throughout their education. The robotic lumbar spine has the potential to satisfy these needs in palpatory diagnosis. Medical students will be given the opportunity to examine their own patient that can be programmed with many dysfunctions related to the lumbar spine before they start their professional lives as doctors. The robotic lumbar spine can be used to teach and test medical students in their capacity to be able to recognize normal and abnormal movement patterns of the human lumbar spine under flexion-extension, lateral bending, and axial torsion. This paper presents the dynamics and nonlinear control of the RLS. A new approach to solve for positive and nonzero cable tensions that are also continuous in time is introduced.


1979 ◽  
Vol 101 (1) ◽  
pp. 46-52 ◽  
Author(s):  
A. B. Schultz ◽  
D. N. Warwick ◽  
M. H. Berkson ◽  
A. L. Nachemson

In this first part of a three-part report, the mechanical behavior of 42 fresh human cadaver lumbar motion segments in flexion, extension, lateral bending, and torsion is examined. Motions and intradiskal pressure changes that occurred in response to these loads, with posterior elements both intact and excised, are reported.


2009 ◽  
Vol 29 (1) ◽  
pp. 165 ◽  
Author(s):  
Adam Rozumalski ◽  
Michael H. Schwartz ◽  
Roy Wervey ◽  
Andrew Swanson ◽  
Daryll C. Dykes ◽  
...  

2003 ◽  
Vol 21 (3) ◽  
pp. 540-546 ◽  
Author(s):  
Avinash G. Patwardhan ◽  
Robert M. Havey ◽  
Gerard Carandang ◽  
James Simonds ◽  
Leonard I. Voronov ◽  
...  

Author(s):  
Marie Christina Keller ◽  
Christof Hurschler ◽  
Michael Schwarze

Abstract Purpose Roentgen stereophotogrammetric analysis is a technique to make accurate assessments of the relative position and orientation of bone structures and implants in vivo. While the precision and accuracy of stereophotogrammetry for hip and knee arthroplasty is well documented, there is insufficient knowledge of the technique’s precision and, especially accuracy when applied to rotational movements in the spinal region. Methods The motion of one cadaver lumbar spine segment (L3/L4) was analyzed in flexion–extension, lateral bending and internal rotation. The specific aim of this study was to examine the precision and accuracy of stereophotogrammetry in a controlled in vitro setting, taking the surrounding soft tissue into account. The second objective of this study was to investigate the effect of different focal spot values of X-ray tubes. Results Overall, the precision of flexion–extension measurements was found to be better when using a 0.6 mm focal spot value rather than 1.2 mm (± 0.056° and ± 0.153°; respectively), and accuracy was also slightly better for the 0.6 mm focal spot value compared to 1.2 mm (− 0.137° and − 0.170°; respectively). The best values for precision and accuracy were obtained in lateral bending for both 0.6 mm and 1.2 mm focal spot values (precision: ± 0.019° and ± 0.015°, respectively; accuracy: − 0.041° and − 0.035°). Conclusion In summary, the results suggest stereophotogrammetry to be a highly precise method to analyze motion of the lumbar spine. Since precision and accuracy are better than 0.2° for both focal spot values, the choice between these is of minor clinical relevance.


Sign in / Sign up

Export Citation Format

Share Document