More than 80% of total knee replacements can last for 25 years

Author(s):  
2021 ◽  
Vol 156 ◽  
pp. 106874 ◽  
Author(s):  
David Nečas ◽  
Martin Vrbka ◽  
Max Marian ◽  
Benedict Rothammer ◽  
Stephan Tremmel ◽  
...  

Polymers ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 1952
Author(s):  
Benedict Rothammer ◽  
Kevin Neusser ◽  
Max Marian ◽  
Marcel Bartz ◽  
Sebastian Krauß ◽  
...  

Diamond-like carbon (DLC) coatings have the potential to reduce implant wear and thus to contribute to avoiding premature failure and increase service life of total knee replacements (TKAs). This two-part study addresses the development of such coatings for ultrahigh molecular weight polyethylene (UHMWPE) tibial inlays as well as cobalt–chromium–molybdenum (CoCr) and titanium (Ti64) alloy femoral components. While a detailed characterization of the tribological behavior is the subject of part II, part I focusses on the deposition of pure (a‑C:H) and tungsten-doped hydrogen-containing amorphous carbon coatings (a‑C:H:W) and the detailed characterization of their chemical, cytological, mechanical and adhesion behavior. The coatings are fabricated by physical vapor deposition (PVD) and display typical DLC morphology and composition, as verified by focused ion beam scanning electron microscopy and Raman spectroscopy. Their roughness is higher than that of the plain substrates. Initial screening with contact angle and surface tension as well as in vitro testing by indirect and direct application indicate favorable cytocompatibility. The DLC coatings feature excellent mechanical properties with a substantial enhancement of indentation hardness and elastic modulus ratios. The adhesion of the coatings as determined in modified scratch tests can be considered as sufficient for the use in TKAs.


2012 ◽  
Vol 94 (3) ◽  
pp. 199-200 ◽  
Author(s):  
S Hassan ◽  
A Wall ◽  
B Ayyawamy ◽  
S Rogers ◽  
SP Mills ◽  
...  

INTRODUCTION Early post-operative x-rays are often taken in total knee replacements (TKRs). Patient mobilisation may be delayed until these x-rays are obtained and this may prolong discharge. The aim of this study was to assess the value of such early x-rays and whether they influenced the early post-operative management of these patients. METHODS A total of 624 consecutive TKRs performed at the Blackpool Victoria Hospital over a 34-month period were evaluated. Plain anteroposterior and lateral x-rays were examined. RESULTS Two patients were found to have significant abnormalities: an undisplaced peri prosthetic tibial fracture and a partial inferior pole patellar avulsion. Neither of these required further treatment or influenced mobility. No other complications were noted that changed routine post-operative management. CONCLUSIONS These results question the need for immediate x-rays in primary TKRs.


Sign in / Sign up

Export Citation Format

Share Document