scholarly journals Evaluation of anatomical variants of sphenoid sinus by multidetector computed tomography

Author(s):  
Dr. Sothu Sri Sravya ◽  
Dr. Chandra Sekhara Rao Kondragunta ◽  
Dr. Kanneganti Dharma Teja ◽  
Dr. Sai Keerthana Mikkilineni ◽  
Dr. Gudavalli Priyanka ◽  
...  
Aorta ◽  
2021 ◽  
Author(s):  
Umberto G. Rossi ◽  
Anna M. Ierardi ◽  
Maurizio Cariati

AbstractWe report the case of a 73-year-old male who underwent abdominal multidetector computed tomography with vascular reconstruction that highlighted a congenital variant of iliac arteries. Iliac artery anatomical variants are exceedingly rare and only a few cases have been reported in the literature.


2008 ◽  
Vol 58 (3) ◽  
pp. 277
Author(s):  
Ji Sang Park ◽  
Seong Jin Park ◽  
Hae Kyung Lee ◽  
Boem Ha Yi ◽  
Hyun Sook Hong ◽  
...  

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


Sign in / Sign up

Export Citation Format

Share Document