scholarly journals Development and Verification of Control Sequences for Single-Zone Variable Air Volume System Based on ASHRAEGuideline 36

Author(s):  
Kun Zhang ◽  
David H. Blum ◽  
Milica Grahovac ◽  
Jianjun Hu ◽  
Jessica Granderson ◽  
...  
2018 ◽  
Vol 38 ◽  
pp. 04012
Author(s):  
Sai Feng Xu ◽  
Xing Lin Yang ◽  
Zou Ying Le

For ocean-going vessels sailing in different areas on the sea, the change of external environment factors will cause frequent changes in load, traditional ship air-conditioning system is usually designed with a fixed cooling capacity, this design method causes serious waste of resources. A new type of sea-based air conditioning system is proposed in this paper, which uses the sea-based source heat pump system, combined with variable air volume, variable water technology. The multifunctional cabins’ dynamic loads for a ship navigating in a typical Eurasian route were calculated based on Simulink. The model can predict changes in full voyage load. Based on the simulation model, the effects of variable air volume and variable water volume on the energy consumption of the air-conditioning system are analyzed. The results show that: When the VAV is coupled with the VWV, the energy saving rate is 23.2%. Therefore, the application of variable air volume and variable water technology to marine air conditioning systems can achieve economical and energy saving advantages.


1998 ◽  
Vol 19 (3) ◽  
pp. 155-162 ◽  
Author(s):  
I. Khoo ◽  
G.J. Levermore ◽  
K.M. Letherman

Sign in / Sign up

Export Citation Format

Share Document