scholarly journals Tracheal Tube-Mounted Camera Assisted Intubation vs. Videolaryngoscopy in Expected Difficult Airway: A Prospective, Randomized Trial (VivaOP Trial)

2021 ◽  
Vol 8 ◽  
Author(s):  
Jörn Grensemann ◽  
Emma Möhlenkamp ◽  
Philipp Breitfeld ◽  
Pischtaz A. Tariparast ◽  
Tanja Peters ◽  
...  

Background: Tracheal intubation in patients with an expected difficult airway may be facilitated by videolaryngoscopy (VL). The VL viewing axis angle is specified by the blade shape and visualization of the larynx may fail if the angle does not meet anatomy of the patient. A tube with an integrated camera at its tip (VST, VivaSight-SL) may be advantageous due to its adjustable viewing axis by means of angulating an included stylet.Methods: With ethics approval, we studied the VST vs. VL in a prospective non-inferiority trial using end-tidal oxygen fractions (etO2) after intubation, first-attempt success rates (FAS), visualization assessed by the percentage of glottis opening (POGO) scale, and time to intubation (TTI) as outcome parameters.Results: In this study, 48 patients with a predicted difficult airway were randomized 1:1 to intubation with VST or VL. Concerning oxygenation, the VST was non-inferior to VL with etO2 of 0.79 ± 0.08 (95% CIs: 0.75–0.82) vs. 0.81 ± 0.06 (0.79–0.84) for the VL group, mean difference 0.02 (−0.07 to 0.02), p = 0.234. FAS was 79% for VST and 88% for VL (p = 0.449). POGO was 89 ± 21% in the VST-group and 60 ± 36% in the VL group, p = 0.002. TTI was 100 ± 57 s in the VST group and 68 ± 65 s in the VL group (p = 0.079). TTI with one attempt was 84 ± 31 s vs. 49 ± 14 s, p < 0.001.Conclusion: In patients with difficult airways, tracheal intubation with the VST is feasible without negative impact on oxygenation, improves visualization but prolongs intubation. The VST deserves further study to identify patients that might benefit from intubation with VST.

2020 ◽  
Author(s):  
Jonathan Zhao Min Lim ◽  
Shi Hao Chew ◽  
Benjamin Zhao Bin Chin ◽  
Raymond Chern Hwee Siew

Abstract Background This study sheds light on the proficiency of military medical officers who had received between 2-3 years of post-graduate training, in the handling of the difficult airway in a trauma manikin simulator using direct and video laryngoscopes. Method 133 doctors from the Singapore Armed Forces Medical Officer Cadet Course were assessed using high-fidelity simulator models with standardised difficult airways (simulator with tongue-swelling and cervical collar). They used the Macintosh direct laryngoscope (DL), King Vision channelled-blade laryngoscope (KVC), King Vision non-channelled blade laryngoscope (KVNC), and the McGrath (MG) laryngoscope on the same model in a randomised sequence. The intubation success rates and time to intubation were recorded and analysed for the study. Results The medical officers had a 71.4% intubation success rate with the DL on the difficult airway trauma simulator model and the mean time to intubation of 40.1s. With the KVC, the success rate is 86.5% with mean intubation time of 40.4s. The KVNC produced 24.8% success rate, with mean time to intubation of 53.2s. The MG laryngoscope produced 85.0% success rate, with a mean time of intubation of 37.4s. Conclusion Military medical officers with 2-3 years of post-graduate training had a success rate of 71.4% success rate intubating a simulated difficult airway in a trauma setting using a DL. Success rates were improved with the use of KVC and the MG laryngoscope, but was worse with the KVNC.


2012 ◽  
Vol 116 (3) ◽  
pp. 629-636 ◽  
Author(s):  
Michael F. Aziz ◽  
Dawn Dillman ◽  
Rongwei Fu ◽  
Ansgar M. Brambrink

Background Video laryngoscopy may be useful in the setting of the difficult airway, but it remains unclear if intubation success is improved in routine difficult airway management. This study compared success rates for tracheal intubation with the C-MAC® video laryngoscope (Karl Storz, Tuttlingen, Germany) with conventional direct laryngoscopy in patients with predicted difficult airway. Methods We conducted a two arm, single-blinded randomized controlled trial that involved 300 patients. Inclusion required at least one of four predictors of difficult intubation. The primary outcome was successful tracheal intubation on first attempt. Results The use of video laryngoscopy resulted in more successful intubations on first attempt (138/149; 93%) as compared with direct laryngoscopy (124/147; 84%), P = 0.026. Cormack-Lehane laryngeal view was graded I or II in 139/149 of C-MAC attempts versus 119/147 in direct laryngoscopy attempts (P < 0.01). Laryngoscopy time averaged 46 s (95% CI, 40-51) for the C-MAC group and was shorter in the direct laryngoscopy group, 33 s (95% CI, 29-36), P < 0.001. The use of a gum-elastic bougie and/or external laryngeal manipulation were required less often in the C-MAC intubations (24%, 33/138) compared with direct laryngoscopy (37%, 46/124, P = 0.020). The incidence of complications was not significantly different between the C-MAC (20%, 27/138) versus direct laryngoscopy (13%, 16/124, P = 0.146). Conclusion A diverse group of anesthesia providers achieved a higher intubation success rate on first attempt with the C-MAC in a broad range of patients with predictors of difficult intubation. C-MAC laryngoscopy seems to be a useful technique for the initial approach to a potentially difficult airway.


2017 ◽  
Vol 127 (3) ◽  
pp. 432-440 ◽  
Author(s):  

Abstract Background The success rates and related complications of various techniques for intubation in children with difficult airways remain unknown. The primary aim of this study is to compare the success rates of fiber-optic intubation via supraglottic airway to videolaryngoscopy in children with difficult airways. Our secondary aim is to compare the complication rates of these techniques. Methods Observational data were collected from 14 sites after management of difficult pediatric airways. Patient age, intubation technique, success per attempt, use of continuous ventilation, and complications were recorded for each case. First-attempt success and complications were compared in subjects managed with fiber-optic intubation via supraglottic airway and videolaryngoscopy. Results Fiber-optic intubation via supraglottic airway and videolaryngoscopy had similar first-attempt success rates (67 of 114, 59% vs. 404 of 786, 51%; odds ratio 1.35; 95% CI, 0.91 to 2.00; P = 0.16). In subjects less than 1 yr old, fiber-optic intubation via supraglottic airway was more successful on the first attempt than videolaryngoscopy (19 of 35, 54% vs. 79 of 220, 36%; odds ratio, 2.12; 95% CI, 1.04 to 4.31; P = 0.042). Complication rates were similar in the two groups (20 vs. 13%; P = 0.096). The incidence of hypoxemia was lower when continuous ventilation through the supraglottic airway was used throughout the fiber-optic intubation attempt. Conclusions In this nonrandomized study, first-attempt success rates were similar for fiber-optic intubation via supraglottic airway and videolaryngoscopy. Fiber-optic intubation via supraglottic airway is associated with higher first-attempt success than videolaryngoscopy in infants with difficult airways. Continuous ventilation through the supraglottic airway during fiber-optic intubation attempts may lower the incidence of hypoxemia.


2020 ◽  
Author(s):  
Jonathan Zhao Min Lim ◽  
Shi Hao Chew ◽  
Benjamin Zhao Bin Chin ◽  
Raymond Chern Hwee Siew

Abstract Background This study sheds light on the proficiency of military medical officers who had received between 2-3 years of post-graduate training, in the handling of the difficult airway in a trauma manikin simulator using direct and video laryngoscopes. Method 133 doctors from the Singapore Armed Forces Medical Officer Cadet Course were assessed using high-fidelity simulator models with standardised difficult airways (simulator with tongue-swelling and cervical collar). They used the Macintosh direct laryngoscope (DL), King Vision channelled-blade laryngoscope (KVC), King Vision non-channelled blade laryngoscope (KVNC), and the McGrath (MG) laryngoscope on the same model in a randomised sequence. The intubation success rates and time to intubation were recorded and analysed for the study. Results The medical officers had a 71.4% intubation success rate with the DL on the difficult airway trauma simulator model and the mean time to intubation of 40.1s. With the KVC, the success rate is 86.5% with mean intubation time of 40.4s. The KVNC produced 24.8% success rate, with mean time to intubation of 53.2s. The MG laryngoscope produced 85.0% success rate, with a mean time of intubation of 37.4s. Conclusion Military medical officers with 2-3 years of post-graduate training had a success rate of 71.4% success rate intubating a simulated difficult airway in a trauma setting using a DL. Success rates were improved with the use of KVC and the MG laryngoscope, but was worse with the KVNC.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Jonathan ZM Lim ◽  
Shi Hao Chew ◽  
Benjamin ZB Chin ◽  
Raymond CH Siew

Abstract Background This study sheds light on the proficiency of military medical officers who had received between 2 and 3 years of post-graduate training, in the handling of the difficult airway in a trauma manikin simulator using direct and video laryngoscopes. Method One hundred thirty-three doctors from the Singapore Armed Forces Medical Officer Cadet Course were assessed using high-fidelity simulator models with standardised difficult airways (simulator with tongue-swelling and cervical collar). They used the Macintosh direct laryngoscope (DL), King Vision channelled-blade laryngoscope (KVC), King Vision non-channelled blade laryngoscope (KVNC), and the McGrath (MG) laryngoscope on the same model in a randomised sequence. The intubation success rates and time to intubation were recorded and analysed for the study. Results The medical officers had a 71.4% intubation success rate with the DL on the difficult airway trauma simulator model and the mean time to intubation of 40.1 s. With the KVC, the success rate is 86.5% with mean intubation time of 40.4 s. The KVNC produced 24.8% success rate, with mean time to intubation of 53.2 s. The MG laryngoscope produced 85.0% success rate, with a mean time of intubation of 37.4 s. Conclusion Military medical officers with 2–3 years of post-graduate training had a success rate of 71.4% success rate intubating a simulated difficult airway in a trauma setting using a DL. Success rates were improved with the use of KVC and the MG laryngoscope, but was worse with the KVNC.


Sign in / Sign up

Export Citation Format

Share Document