scholarly journals Intracochlear Recordings of Acoustically and Electrically Evoked Potentials in Nucleus Hybrid L24 Cochlear Implant Users and Their Relationship to Speech Perception

2017 ◽  
Vol 11 ◽  
Author(s):  
Jae-Ryong Kim ◽  
Viral D. Tejani ◽  
Paul J. Abbas ◽  
Carolyn J. Brown
2012 ◽  
Vol 33 (3) ◽  
pp. 389-398 ◽  
Author(s):  
Benjamin Kirby ◽  
Carolyn Brown ◽  
Paul Abbas ◽  
Christine Etler ◽  
Sara O’Brien

1998 ◽  
Vol 27 (1) ◽  
pp. 13-20 ◽  
Author(s):  
Mohammad Jamal Makhdoum ◽  
Paul A.P. Groenen ◽  
Ad F.M. Snik ◽  
Paul van den Broek

2012 ◽  
Vol 76 (9) ◽  
pp. 1332-1338 ◽  
Author(s):  
Kátia F. Alvarenga ◽  
Raquel Beltrão Amorim ◽  
Raquel Sampaio Agostinho-Pesse ◽  
Orozimbo Alves Costa ◽  
Leandra Tabanez Nascimento ◽  
...  

2010 ◽  
Vol 10 ◽  
pp. 329-339 ◽  
Author(s):  
Torsten Rahne ◽  
Michael Ziese ◽  
Dorothea Rostalski ◽  
Roland Mühler

This paper describes a logatome discrimination test for the assessment of speech perception in cochlear implant users (CI users), based on a multilingual speech database, the Oldenburg Logatome Corpus, which was originally recorded for the comparison of human and automated speech recognition. The logatome discrimination task is based on the presentation of 100 logatome pairs (i.e., nonsense syllables) with balanced representations of alternating “vowel-replacement” and “consonant-replacement” paradigms in order to assess phoneme confusions. Thirteen adult normal hearing listeners and eight adult CI users, including both good and poor performers, were included in the study and completed the test after their speech intelligibility abilities were evaluated with an established sentence test in noise. Furthermore, the discrimination abilities were measured electrophysiologically by recording the mismatch negativity (MMN) as a component of auditory event-related potentials. The results show a clear MMN response only for normal hearing listeners and CI users with good performance, correlating with their logatome discrimination abilities. Higher discrimination scores for vowel-replacement paradigms than for the consonant-replacement paradigms were found. We conclude that the logatome discrimination test is well suited to monitor the speech perception skills of CI users. Due to the large number of available spoken logatome items, the Oldenburg Logatome Corpus appears to provide a useful and powerful basis for further development of speech perception tests for CI users.


2021 ◽  
Vol 11 (2) ◽  
pp. 220-226
Author(s):  
Yew-Song Cheng ◽  
Mario A. Svirsky

The presence of spiral ganglion cells (SGCs) is widely accepted to be a prerequisite for successful speech perception with a cochlear implant (CI), because SGCs provide the only known conduit between the implant electrode and the central auditory system. By extension, it has been hypothesized that the number of SGCs might be an important factor in CI outcomes. An impressive body of work has been published on findings from the laborious process of collecting temporal bones from CI users and counting the number of SGCs to correlate those numbers with speech perception scores, but the findings thus far have been conflicting. We performed a meta-analysis of all published studies with the hope that combining existing data may help us reach a more definitive conclusion about the relationship between SGC count and speech perception scores in adults.


1993 ◽  
Vol 94 (6) ◽  
pp. 3178-3189 ◽  
Author(s):  
R. J. M. van Hoesel ◽  
Y. C. Tong ◽  
R. D. Hollow ◽  
G. M. Clark

2015 ◽  
Vol 24 (4) ◽  
pp. 462-468 ◽  
Author(s):  
Jessica J. Messersmith ◽  
Lindsey E. Jorgensen ◽  
Jessica A. Hagg

Purpose The purpose of this study was to determine whether an alternate fitting strategy, specifically adjustment to gains in a hearing aid (HA), would improve performance in patients who experienced poorer performance in the bimodal condition when the HA was fit to traditional targets. Method This study was a retrospective chart review from a local clinic population seen during a 6-month period. Participants included 6 users of bimodal stimulation. Two performed poorer in the cochlear implant (CI) + HA condition than in the CI-only condition. One individual performed higher in the bimodal condition, but the overall performance was low. Three age range–matched users whose performance increased when the HA was used in conjunction with a CI were also included. The HA gain was reduced beyond 2000 Hz. Speech perception scores were obtained pre- and postmodification to the HA fitting. Results All listeners whose HA was programmed using the modified approach demonstrated improved speech perception scores with the modified HA fit in the bimodal condition when compared with the traditional HA fit in the bimodal condition. Conclusion Modifications to gains above 2000 Hz in the HA may improve performance for bimodal listeners who perform more poorly in the bimodal condition when the HA is fit to traditional targets.


Sign in / Sign up

Export Citation Format

Share Document