Reduction in High-Frequency Hearing Aid Gain Can Improve Performance in Patients With Contralateral Cochlear Implant: A Pilot Study

2015 ◽  
Vol 24 (4) ◽  
pp. 462-468 ◽  
Author(s):  
Jessica J. Messersmith ◽  
Lindsey E. Jorgensen ◽  
Jessica A. Hagg

Purpose The purpose of this study was to determine whether an alternate fitting strategy, specifically adjustment to gains in a hearing aid (HA), would improve performance in patients who experienced poorer performance in the bimodal condition when the HA was fit to traditional targets. Method This study was a retrospective chart review from a local clinic population seen during a 6-month period. Participants included 6 users of bimodal stimulation. Two performed poorer in the cochlear implant (CI) + HA condition than in the CI-only condition. One individual performed higher in the bimodal condition, but the overall performance was low. Three age range–matched users whose performance increased when the HA was used in conjunction with a CI were also included. The HA gain was reduced beyond 2000 Hz. Speech perception scores were obtained pre- and postmodification to the HA fitting. Results All listeners whose HA was programmed using the modified approach demonstrated improved speech perception scores with the modified HA fit in the bimodal condition when compared with the traditional HA fit in the bimodal condition. Conclusion Modifications to gains above 2000 Hz in the HA may improve performance for bimodal listeners who perform more poorly in the bimodal condition when the HA is fit to traditional targets.

2016 ◽  
Vol 59 (1) ◽  
pp. 99-109 ◽  
Author(s):  
Jennifer R. Fowler ◽  
Jessica L. Eggleston ◽  
Kelly M. Reavis ◽  
Garnett P. McMillan ◽  
Lina A. J. Reiss

PurposeThe objective was to determine whether speech perception could be improved for bimodal listeners (those using a cochlear implant [CI] in one ear and hearing aid in the contralateral ear) by removing low-frequency information provided by the CI, thereby reducing acoustic–electric overlap.MethodSubjects were adult CI subjects with at least 1 year of CI experience. Nine subjects were evaluated in the CI-only condition (control condition), and 26 subjects were evaluated in the bimodal condition. CIs were programmed with 4 experimental programs in which the low cutoff frequency (LCF) was progressively raised. Speech perception was evaluated using Consonant-Nucleus-Consonant words in quiet, AzBio sentences in background babble, and spondee words in background babble.ResultsThe CI-only group showed decreased speech perception in both quiet and noise as the LCF was raised. Bimodal subjects with better hearing in the hearing aid ear (< 60 dB HL at 250 and 500 Hz) performed best for words in quiet as the LCF was raised. In contrast, bimodal subjects with worse hearing (> 60 dB HL at 250 and 500 Hz) performed similarly to the CI-only group.ConclusionsThese findings suggest that reducing low-frequency overlap of the CI and contralateral hearing aid may improve performance in quiet for some bimodal listeners with better hearing.


Author(s):  
Gauri Belsare ◽  
Sharda Sarda ◽  
Prakash Bhardwaj ◽  
Sai Belsare

Abstract Introduction There are very few studies comparing speech perception abilities of children using bimodal hearing over monaural cochlear implant and factors related to benefit of bimodal hearing. The aim of this study is to compare speech perception abilities of children using bimodal fitting versus children using cochlear implant alone and explore factors related to benefit of bimodal hearing. Materials and Methods In the present study, 20 cochlear implantees with the hearing age range of 3 to 8 years were included. Speech perception performance was assessed by means of Parent’s Evaluation of Aural/Oral Performance of Children scale and early speech perception (ESP) test: Pattern Perception Words, Monosyllabic Words, Bisyllabic, and Trisyllabic Words Identification test. ESP test was carried out in two conditions cochlear implant with hearing aid in opposite ear (CIHA), bimodal, and cochlear implant (CI) alone. Aided audiometry was also carried out in above mentioned two conditions. Results and Discussion On aided audiometry test, aided thresholds were improved by 5 to 6 dB in CIHA condition as compared to CI alone condition in 14 out of 20 children. Whereas on speech perception test, there was a significant improvement of 15 to 20% on domains of ESP test in these children. Factors such as implant age, chronological age, and number of hours of hearing aid usage were not significantly associated with benefit. Nevertheless aided threshold at 4,000 Hz was found to be significantly associated with bimodal benefit. Conclusion Bimodal hearing is beneficial in most of the children than monaural hearing through cochlear implant.


2016 ◽  
Vol 21 (03) ◽  
pp. 206-212 ◽  
Author(s):  
Grace Ciscare ◽  
Erika Mantello ◽  
Carla Fortunato-Queiroz ◽  
Miguel Hyppolito ◽  
Ana Reis

Introduction A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1.


2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Su Wu ◽  
Qian-qi Liu ◽  
Wei Gu ◽  
Shi-ning Ni ◽  
Xing Shi ◽  
...  

Objective. To describe the demographic features of children with short stature and poor growth in the south of China and provide better guidance on clinical strategy and decisions. Study Design. This retrospective, chart review study analyzed children with short stature and poor growth admitted to the Department of Endocrinology of Children’s Hospital of Nanjing Medical University from Jan 2007 to Dec 2015. Results. The chart review yielded 4142 patients, including 2546 boys and 1596 girls (P < 0.001); the number of patients gradually increased per year from 2007 to 2015. There was an upward trend in the average levels of height standard deviations (SDs) during the study period (P < 0.001), both in males (P < 0.001) and females (P < 0.001). Mean height SDs were smaller in females (-2.42±1.09) than males (-2.33±1.03; P = 0.01). The percentage of females admitted at normal height (33.83%) was lower than that of males (37.20%; P = 0.028). The peak age range of hospitalization in males was 10–12 years of age, while females were generally admitted earlier—8–10 years. Conclusions. There was an increasing tendency to focus on children’s height. Parents and pediatricians were recommended to pay more attention to the treatment needs of girls while avoiding excessive treatment of those who merely appear not to be tall enough without a clear medical issue related to growth, especially for boys.


2007 ◽  
Author(s):  
James D. Miller ◽  
Charles S. Watson ◽  
Doris J. Kistler ◽  
Frederic L. Wightman ◽  
Jill E. Preminger

1990 ◽  
Vol 33 (2) ◽  
pp. 229-237 ◽  
Author(s):  
Arlene Earley Carney ◽  
Marjorie Kienle ◽  
Richard T. Miyamoto

Suprasegmental and segmental speech perception tasks were administered to 8 patients with single-channel cochlear implants. Suprasegmental tasks included the recognition of syllable number, syllabic stress, and intonation. Segmental tasks included the recognition of vowels and consonants in three modalities: visual only, implant only, and visual + implant. Results were compared to those obtained from artificially deafened adults using a single-channel vibrotactile device (Carney, 1988; Carney & Beachler, 1986). The patterns of responses for both suprasegmental and segmental tasks were highly similar for both groups of subjects, despite differences between the characteristics of the subject samples. These results suggest that single-channel sensory devices, whether they be cochlear implants or vibrotactile aids, produce similar patterns of speech perception errors, even when differences are observed in overall performance level.


2003 ◽  
Vol 67 (10) ◽  
pp. 1061-1067 ◽  
Author(s):  
Shoichiro Fukuda ◽  
Kunihiro Fukushima ◽  
Naomi Toida ◽  
Keiko Tsukamura ◽  
Yukihide Maeda ◽  
...  

2011 ◽  
Vol 22 (09) ◽  
pp. 567-577 ◽  
Author(s):  
Christina L. Runge ◽  
Jamie Jensen ◽  
David R. Friedland ◽  
Ruth Y. Litovsky ◽  
Sergey Tarima

Background: The challenges associated with auditory neuropathy spectrum disorder (ANSD) are due primarily to temporal impairment and therefore tend to affect perception of low- to midfrequency sounds. A common treatment option for severe impairment in ANSD is cochlear implantation, and because the degree of impairment is unrelated to degree of hearing loss by audiometric thresholds, this population may have significant acoustic sensitivity in the contralateral ear. Clinically, the question arises as to how we should treat the contralateral ear in this population when there is acoustic hearing—should we plug it, amplify it, implant it, or leave it alone? Purpose: The purpose of this study was to examine the effects of acute amplification and plugging of the contralateral ear compared to no intervention in implanted children with ANSD and aidable contralateral hearing. It was hypothesized that due to impaired temporal processing in ANSD, contralateral acoustic input would interfere with speech perception achieved with the cochlear implant (CI) alone; therefore, speech perception performance will decline with amplification and improve with occlusion. Research Design: Prospective within-subject comparison. Adaptive speech recognition thresholds (SRTs) for monosyllable and spondee word stimuli were measured in quiet and in noise for the intervention configurations. Study Sample: Nine children treated at the Medical College of Wisconsin Koss Cochlear Implant Program participated in the study. Inclusion criteria for this study were children diagnosed with ANSD who were unilaterally implanted, had aidable hearing in the contralateral ear (defined as a three-frequency pure-tone average of ≤80 dB HL), had at least 1 yr of cochlear implant experience, and were able to perform the speech perception task. Intervention: We compared SRT with the CI alone to SRTs with interventions of cochlear implant with a contralateral hearing aid (CI+HA) and cochlear implant with a contralateral earplug (CI+plug). Data Collection and Analysis: SRTs were measured and compared within subjects across listening conditions. Within-subject comparisons were analyzed using paired t-tests, and analyses of predictive variables for effects of contralateral intervention were analyzed using linear regression. Results: Contrary to the hypothesis, the bimodal CI+HA configuration showed a significant improvement in mean performance over the CI-alone configuration in quiet (p = .04). In noise, SRTs were obtained for six subjects, and no significant bimodal benefit was observed (p = .09). There were no consistent effects of occlusion observed across subjects and stimulus conditions. Degree of bimodal benefit showed a significant relationship with performance with the CI alone, with greater bimodal benefit associated with poorer CI-alone performance (p = .01). This finding, however, was limited by floor effects. Conclusions: The results of this study indicate that children with ANSD who are experienced cochlear implant users may benefit from contralateral amplification, particularly for moderate cochlear implant performers. It is unclear from these data whether long-term contralateral hearing aid use in real-world situations would ultimately benefit this population; however, a hearing aid trial is recommended with assessment of bimodal benefit over time. These data may help inform clinical guidelines for determining optimal hearing configurations for unilaterally implanted children with ANSD, particularly when considering candidacy for sequential cochlear implantation.


2009 ◽  
Vol 20 (06) ◽  
pp. 353-373 ◽  
Author(s):  
Lisa G. Potts ◽  
Margaret W. Skinner ◽  
Ruth A. Litovsky ◽  
Michael J. Strube ◽  
Francis Kuk

Background: The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). Purpose: This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. Research Design: A repeated-measures correlational study was completed. Study Sample: Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. Intervention: The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Data Collection and Analysis: Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six–eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Results: Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant–only and hearing aid–only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1–3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. Conclusions: These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid.


Sign in / Sign up

Export Citation Format

Share Document