scholarly journals On the Contribution of Wind Farms in Automatic Generation Control: Review and New Control Approach

2018 ◽  
Vol 8 (10) ◽  
pp. 1848 ◽  
Author(s):  
Arman Oshnoei ◽  
Rahmat Khezri ◽  
SM Muyeen ◽  
Frede Blaabjerg

Wind farms can contribute to ancillary services to the power system, by advancing and adopting new control techniques in existing, and also in new, wind turbine generator systems. One of the most important aspects of ancillary service related to wind farms is frequency regulation, which is partitioned into inertial response, primary control, and supplementary control or automatic generation control (AGC). The contribution of wind farms for the first two is well addressed in literature; however, the AGC and its associated controls require more attention. In this paper, in the first step, the contribution of wind farms in supplementary/load frequency control of AGC is overviewed. As second step, a fractional order proportional-integral-differential (FOPID) controller is proposed to control the governor speed of wind turbine to contribute to the AGC. The performance of FOPID controller is compared with classic proportional-integral-differential (PID) controller, to demonstrate the efficacy of the proposed control method in the frequency regulation of a two-area power system. Furthermore, the effect of penetration level of wind farms on the load frequency control is analyzed.

2010 ◽  
Vol 2 (2) ◽  
pp. 285-293 ◽  
Author(s):  
M. R. I. Sheikh ◽  
R. Takahashi ◽  
J. Tamura

Since superconducting magnetic energy storage (SMES) unit with a self-commutated converter is capable of controlling both the active and reactive powers simultaneously and quickly, increasing attention has been focused recently on power system stabilization by SMES control. This study presents the effects of novel control strategies of self-tuned fuzzy proportional integral (FPI) controller and fuzzy frequency (FF) controller associated with the automatic generation control (AGC) including SMES unit. The effects of the self-tuning configuration with FPI controller in AGC is also compared with that of FF controlled AGC on SMES control. The simulation results show that both self tuning control schemes of AGC are very effective in damping out of the oscillations caused by load disturbances and it is also seen that the FF controlled AGC with SMES perform better primary frequency control compared to FPI controlled AGC with SMES. Keywords: Load frequency control; Single area power system; FPI controller; FF controller; SMES unit. © 2010 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.    DOI: 10.3329/jsr.v2i2.3063               J. Sci. Res. 2 (2), 285-293 (2010) 


Author(s):  
Abdullahi Bala Kunya ◽  
Mehmet Argin ◽  
Yusuf Jibril ◽  
Yusuf Abubakar Shaaban

Abstract Background Automatic generation control (AGC) of multi-area interconnected power system (IPS) is often designed with negligible cross-coupling between the load frequency control (LFC) and automatic voltage regulation (AVR) loops. This is because the AVR loop is considerably faster than that of LFC. However, with the introduction of slow optimal control action on the AVR, positive damping effect can be achieved on the LFC loop thereby improving the frequency control. In this paper, LFC synchronized with AVR in three-area IPS is proposed. Model predictive controller (MPC) configured in a dense distributed pattern, due to its online set-point tacking is used as the supplementary controller. The dynamics of the IPS subjected to multi-area step and random load disturbances are studied. The efficacy of the developed scheme is ascertained by simulating the disturbed system in MATLAB/Simulink. Results Based on the comparative analysis on the system responses, it is established that by cross-coupling the LFC loop with AVR, reductions of 66.45% and 59.09% in the frequency and tie-line power maximum deviations respectively are observed, while the respective settling times are found to be reduced by 29.68% and 22.77% when compared with the uncoordinated control scheme. In addition, the standard deviation and variance of the integral time absolute error of the system’s responses have reduced by 23.21% and 20.83% respectively compared to those obtained in a similar study. Conclusions The reduction in the maximum deviations and settling times in the system states indicates that introducing the voltage control via AVR loop has improved the frequency control significantly. While the lower standard deviation and variance of the integral time absolute error signify improvement in the robustness of the developed algorithm. However, this improvement is at the detriment of the controller size and computational complexity. In the uncoordinated control scheme, the control vector is one-dimensional, while in the coordinated scheme, the control vector is two-dimensional for each CA.