scholarly journals Real-Time Monitoring of Indoor Air Quality with Internet of Things-Based E-Nose

2019 ◽  
Vol 9 (16) ◽  
pp. 3435 ◽  
Author(s):  
Mehmet Taştan ◽  
Hayrettin Gökozan

Today, air pollution is the biggest environmental health problem in the world. Air pollution leads to adverse effects on human health, climate and ecosystems. Air is contaminated by toxic gases released by industry, vehicle emissions and the increased concentration of harmful gases and particulate matter in the atmosphere. Air pollution can cause many serious health problems such as respiratory, cardiovascular and skin diseases in humans. Nowadays, where air pollution has become the largest environmental health risk, the interest in monitoring air quality is increasing. Recently, mobile technologies, especially the Internet of Things, data and machine learning technologies have a positive impact on the way we manage our health. With the production of IoT-based portable air quality measuring devices and their widespread use, people can monitor the air quality in their living areas instantly. In this study, e-nose, a real-time mobile air quality monitoring system with various air parameters such as CO2, CO, PM10, NO2 temperature and humidity, is proposed. The proposed e-nose is produced with an open source, low cost, easy installation and do-it-yourself approach. The air quality data measured by the GP2Y1010AU, MH-Z14, MICS-4514 and DHT22 sensor array can be monitored via the 32-bit ESP32 Wi-Fi controller and the mobile interface developed by the Blynk IoT platform, and the received data are recorded in a cloud server. Following evaluation of results obtained from the indoor measurements, it was shown that a decrease of indoor air quality was influenced by the number of people in the house and natural emissions due to activities such as sleeping, cleaning and cooking. However, it is observed that even daily manual natural ventilation has a significant improving effect on air quality.

2022 ◽  
Vol 14 (2) ◽  
pp. 739
Author(s):  
Fernando del Ama Gonzalo ◽  
Matthew Griffin ◽  
Jacob Laskosky ◽  
Peter Yost ◽  
Roberto Alonso González-Lezcano

Several studies on indoor air quality (IAQ) and sick building syndromes have been completed over the last decade, especially in cold countries. Efforts to make homes airtight to improve energy efficiency have created buildings with low ventilation rates, resulting in the build-up of indoor pollutants to harmful levels that would be otherwise unacceptable outdoors. This paper analyzed the infiltration rates, indoor temperatures, and variations in CO2, 2.5 μm particulate matter (PM2.5), and total volatile organic compound (TVOC) concentrations over the fall of 2021 in several homes in New England, USA. A relationship between outdoor and indoor conditions and ventilation strategies has been set using the results from blower door tests and actual indoor air quality data. Although all case studies lacked mechanical ventilation devices, such as those required by ASHRAE Standard 62.2, natural ventilation and air leakage have been enough to keep VOCs and PM2.5 concentration levels at acceptable values most of the studied time. However, results revealed that 25% of a specific timeframe, the occupants have been exposed to concentration levels of CO2 above 1000 parts per million (ppm), which are considered potentially hazardous conditions.


Electronics ◽  
2019 ◽  
Vol 8 (2) ◽  
pp. 170 ◽  
Author(s):  
Gonçalo Marques ◽  
Rui Pitarma

We spend about 90% of our lives in indoor living environments. Thus, it is essential to provide indoor air quality monitoring for enhanced living environments. Advances in networking, sensors, and embedded devices have made monitoring and supply of assistance possible to people in their homes. Technological advancements have made possible the building of smart devices with significant capabilities for sensing and connecting, but also provide several improvements in ambient assisted living system architectures. Indoor air quality assumes an important role in building productive and healthy indoor environments. In this paper, the authors present an Internet of Things system for real-time indoor air quality monitoring named iAir. This system is composed by an ESP8266 as the communication and processing unit and a MICS-6814 sensor as the sensing unit. The MICS-6814 is a metal oxide semiconductor sensor capable of detecting several gases such as carbon monoxide, nitrogen dioxide, ethanol, methane, and propane. The iAir system also provides a smartphone application for data consulting and real-time notifications. Compared to other solutions, the iAir system is based on open-source technologies and operates as a totally Wi-Fi system, with several advantages such as its modularity, scalability, low cost, and easy installation. The results obtained are very promising, representing a meaningful contribution for enhanced living environments as iAir provides real-time monitoring for enhanced ambient assisted living and occupational health.


Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4157 ◽  
Author(s):  
Shengjing Sun ◽  
Xiaochen Zheng ◽  
Javier Villalba-Díez ◽  
Joaquín Ordieres-Meré

Indoor air pollution has been ranked among the top five environmental risks to public health. Indoor Air Quality (IAQ) is proven to have significant impacts on people’s comfort, health, and performance. Through a systematic literature review in the area of IAQ, two gaps have been identified by this study: short-term monitoring bias and IAQ data-monitoring solution challenges. The study addresses those gaps by proposing an Internet of Things (IoT) and Distributed Ledger Technologies (DLT)-based IAQ data-monitoring system. The developed data-monitoring solution allows for the possibility of low-cost, long-term, real-time, and summarized IAQ information benefiting all stakeholders contributing to define a rich context for Industry 4.0. The solution helps the penetration of Industrial Internet of Things (IIoT)-based monitoring strategies in the specific case of Occupational Safety Health (OSH). The study discussed the corresponding benefits OSH regulation, IAQ managerial, and transparency perspectives based on two case studies conducted in Spain.


2021 ◽  
pp. 100392
Author(s):  
Dylan Wall ◽  
Paul McCullagh ◽  
Ian Cleland ◽  
Raymond Bond

Author(s):  
Farhang Tahmasebi ◽  
Yan Wang ◽  
Elizabeth Cooper ◽  
Daniel Godoy Shimizu ◽  
Samuel Stamp ◽  
...  

The Covid-19 outbreak has resulted in new patterns of home occupancy, the implications of which for indoor air quality (IAQ) and energy use are not well-known. In this context, the present study investigates 8 flats in London to uncover if during a lockdown, (a) IAQ in the monitored flats deteriorated, (b) the patterns of window operation by occupants changed, and (c) more effective ventilation patterns could enhance IAQ without significant increases in heating energy demand. To this end, one-year’s worth of monitored data on indoor and outdoor environment along with occupant use of windows has been used to analyse the impact of lockdown on IAQ and infer probabilistic models of window operation behaviour. Moreover, using on-site CO2 data, monitored occupancy and operation of windows, the team has calibrated a thermal performance model of one of the flats to investigate the implications of alternative ventilation strategies. The results suggest that despite the extended occupancy during lockdown, occupants relied less on natural ventilation, which led to an increase of median CO2 concentration by up to 300 ppm. However, simple natural ventilation patterns or use of mechanical ventilation with heat recovery proves to be very effective to maintain acceptable IAQ. Practical application: This study provides evidence on the deterioration of indoor air quality resulting from homeworking during imposed lockdowns. It also tests and recommends specific ventilation strategies to maintain acceptable indoor air quality at home despite the extended occupancy hours.


Sign in / Sign up

Export Citation Format

Share Document