scholarly journals Experimental Investigation on Semi-Active Control of Base Isolation System Using Magnetorheological Dampers for Concrete Frame Structure

2019 ◽  
Vol 9 (18) ◽  
pp. 3866 ◽  
Author(s):  
Weiqing Fu ◽  
Chunwei Zhang ◽  
Mao Li ◽  
Cunkun Duan

The traditional passive base isolation is the most widely used method in the engineering practice for structural control, however, it has the shortcoming that the optimal control frequency band is significantly limited and narrow. For the seismic isolation system designed specifically for large earthquakes, the structural acceleration response may be enlarged under small earthquakes. If the design requirements under small earthquakes are satisfied, the deformation in the isolation layer may become too large to be accepted. Occasionally, it may be destroyed under large earthquakes. In the isolation control system combined with rubber bearing and magnetorheological (MR) damper, the MR damper can provide instantaneous variable damping force to effectively control the structural response at different input magnitudes. In this paper, the control effect of semi-active control and quasi-passive control for the isolation control system is verified by the shaking table test. In regard to semi-active control, the linear quadratic regulator (LQR) classical linear optimal control algorithm by continuous control and switch control strategies are used to control the structural vibration response. Numerical simulation analysis and shaking table test results indicate that isolation control system can effectively overcome the shortcoming due to narrow optimum control band of the passive isolation system, and thus to provide optimal control for different seismic excitations in a wider frequency range. It shows that, even under super large earthquakes, the structure still exhibits the ability to maintain overall stability performance.

2012 ◽  
Vol 446-449 ◽  
pp. 378-381
Author(s):  
Jian Min Jin ◽  
Ping Tan ◽  
Fu Lin Zhou ◽  
Yu Hong Ma ◽  
Chao Yong Shen

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with lead rubber bearing are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.


2010 ◽  
Vol 163-167 ◽  
pp. 4179-4184 ◽  
Author(s):  
He Len Wu

The paper proposes an aseismic hybrid control system to control the response of structures subjected to large ground motions caused by large magnitude earthquakes. The proposed hybrid control system consists of a base isolation system (laminated rubber bearings) connected to an active control system (a tuned mass damper and an actuator). The base isolation system is used to decouple the horizontal ground motions from the structure, whereas the active control system is used to protect the safety and integrity of the base isolation system. A 5-story benchmark building model is developed to study the effectiveness of the hybrid control system against different ground motions. It was found from the numerical results that rubber bearing system alone shows good performance and resists ground motion due to Hachinohe 1968, Kobe 1995, and Northridge 1994 earthquakes, but is somewhat unable to protect the model against El-Centro 1940 earthquake. After the installation of an active control system onto the rubber-isolated model, further improvements to earthquake resistance against these four earthquakes were observed, especially against the El-Centro earthquake. The merit of the hybrid control system lies in its capability to protect against different ground motions, with varying intensity and frequency content.


1995 ◽  
pp. 167-177 ◽  
Author(s):  
Susumu Okamoto ◽  
Shunji Fujii ◽  
Daisuke Ozaki ◽  
M. C. Constantinou ◽  
P. C. Tsopelas

2012 ◽  
Vol 226-228 ◽  
pp. 1149-1152
Author(s):  
Jian Min Jin ◽  
Ping Tan ◽  
Fu Lin Zhou ◽  
Xiang Yun Huang

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with linear natural rubber bearing and viscous damper are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.


2008 ◽  
Vol 14 (27) ◽  
pp. 49-54 ◽  
Author(s):  
Ken'ichi KAWAGUCHI ◽  
Keiichi ABE ◽  
Jun'ichiro ABE ◽  
Tomoyasu TAGUCHI ◽  
Ryota TAKAHAMA