Shaking Table Test Study on Mid-Story Isolation Structures

2012 ◽  
Vol 446-449 ◽  
pp. 378-381
Author(s):  
Jian Min Jin ◽  
Ping Tan ◽  
Fu Lin Zhou ◽  
Yu Hong Ma ◽  
Chao Yong Shen

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with lead rubber bearing are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.

2012 ◽  
Vol 226-228 ◽  
pp. 1149-1152
Author(s):  
Jian Min Jin ◽  
Ping Tan ◽  
Fu Lin Zhou ◽  
Xiang Yun Huang

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with linear natural rubber bearing and viscous damper are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.


2013 ◽  
Vol 859 ◽  
pp. 33-42
Author(s):  
Mei Gen Cao ◽  
Juan Mo

Earthquake damage many times in history indicate thatthe destroy type of large power transformer is diverse in earthquake andvulnerability is very high. Isolationtechnology can effectively reduce seismic response of the transformer and bushings,but transformer isolation layer design and parameter selection have a largerimpact on the isolation effect. Firstly, one transformer model installing 220,500kV real bushings for testing and analysis is designed which its structural dimension is closer totrue transformer. Multi-particle analysis model of the transformer withbushings isolation system (TBIS)and the equations of motion are established, and calculationprocedures are compiled using MATLABprogram. Secondly, impacts analysis on equivalent horizontal stiffness and dampingratio of the isolation layer are carried out subjectedto earthquake. Reasonable ranges ofstiffness and damping parameters have been determined. Earthquake simulatortesting of the transformer with real bushings is implement which transformertank filled with water in the test. Acceleration, displacement and stressresponse of transformer and bushings with or without isolation bearings wereobtained. Analysis and experiments show that the rational designing isolationlayer parameters can effectively reduce the seismic response of transformers andbushings. In conclusion, mentioned above research have reference role toseismic isolation design and application for power transformer and bushings forthe future.


2014 ◽  
Vol 1010-1012 ◽  
pp. 250-253
Author(s):  
Ji Yang Li ◽  
Wen Fang Zhang

Seismic can be divided into passive seismic and active seismic. Seismic isolation technology belong to the second type. Base isolation structure is defined by setting the isolation layer between the superstructure and foundation building, to extend the natural period architecture, increasing the damping to reduce structural seismic response. It is a passive control system. Compared with the traditional seismic structure, it mainly through the isolation layer to absorb and dissipate energy, reducing the response to the earthquake.


Author(s):  
Osamu Furuya ◽  
Kiyotaka Takito ◽  
Hiroshi Kurabayashi ◽  
Kunio Sampei ◽  
Koji Yamazaki

Abstract Vibration isolation devices are generally applied to equipment that dislikes vibration installed in buildings. Since the vibration isolator is intended for small vibration input, the damage has been frequently confirmed with excessive vibration input such as an huge earthquake motion. Therefore, the development of a seismic isolation device with a vibration isolation function is desired for important equipment and expensive manufacturing equipment. However, the vibration region targeted by the vibration isolator and the vibration region of the seismic input are at completely different levels. In this study, the authors propose a seismic isolation system using air floating technique to cope with such different vibration levels. In this paper, basic concept, basic performance, preliminary performance evaluation by nonlinear time response analysis, and performance evaluation by shaking table test.


Author(s):  
Kiyotaka Takito ◽  
Osamu Furuya ◽  
Hiroshi Kurabayashi ◽  
Kunio Sanpei

Abstract In Japan, most structures on the ground surface need seismic countermeasures because of frequently earthquakes. On the other hand, vibration isolation devices are applied to precision or important equipment in several facilities that dislikes vibration in order to reduce daily vibration. In general, vibration isolation devices are intended for high frequency and small amplitude range. However, it is difficult to cut off both vibration region caused by flying object collision and seismic motion with existing technologies. The authors propose insulation of equipment and vibration transmitted through the floor by floating equipment, and have. We have devised and built an air floating device that operates when a trigger input is applied to save the energy of this dynamically acting device. It was estimated by numerical calculation that the aero floating device keeps lifting stably in the condition with the air pressure in the auxiliary air chamber about 75 to 80 kPa. The performance specifications of the proposed device were verified from shaking table test. As a result, the effect of reducing the maximum acceleration by about 1/5 against the seismic motion of El Centro NS, Taft NS, Tohoku NS, and Hachinohe EW was confirmed by floating the mass on the frame assuming the equipment. From the obtained power spectrum diagram (PSD) of the response acceleration, it was confirmed that all frequency components up to 25 Hz is reduced by using proposed aero floating base isolation device.


Author(s):  
Shigeru Aoki ◽  
Yuji Nakanishi ◽  
Kazutoshi Tominaga ◽  
Takeshi Otaka ◽  
Tadashi Nishimura ◽  
...  

Reduction of seismic response of mechanical system is important problem for aseismic design. Some types of base isolation systems are developed and used in actual base of buildings and floors in buildings for reduction of seismic response of mechanincal system. In this paper, a base isolation system utilizing bearing with friction and restoring force of bearing is proposed. Friction bearing consists of two plates having spherical concaves and oval type metal or spherical metal with rubber. First, effectiveness of the base isolation system is examined experimentally. Using artificial time histories, the isolated table is shaken on the shaking table. The maximum value of response is reduced and sum of squares of response is significantly reduced. Power spectrum is significantly reduced in almost of all frequency regions, except for very low frequency region. Next, in order to examine reduction of seismic response of actual mechanical system, a console rack is set on the isolated plate. Seismic response is also significantly reduced. Finally, obtained results of experiment are examined by simulation method. An analytical model considering friction and restoring force is used. From simulation method, effectiveness of the proposed base isolation system is demonstrated.


2019 ◽  
Vol 9 (18) ◽  
pp. 3866 ◽  
Author(s):  
Weiqing Fu ◽  
Chunwei Zhang ◽  
Mao Li ◽  
Cunkun Duan

The traditional passive base isolation is the most widely used method in the engineering practice for structural control, however, it has the shortcoming that the optimal control frequency band is significantly limited and narrow. For the seismic isolation system designed specifically for large earthquakes, the structural acceleration response may be enlarged under small earthquakes. If the design requirements under small earthquakes are satisfied, the deformation in the isolation layer may become too large to be accepted. Occasionally, it may be destroyed under large earthquakes. In the isolation control system combined with rubber bearing and magnetorheological (MR) damper, the MR damper can provide instantaneous variable damping force to effectively control the structural response at different input magnitudes. In this paper, the control effect of semi-active control and quasi-passive control for the isolation control system is verified by the shaking table test. In regard to semi-active control, the linear quadratic regulator (LQR) classical linear optimal control algorithm by continuous control and switch control strategies are used to control the structural vibration response. Numerical simulation analysis and shaking table test results indicate that isolation control system can effectively overcome the shortcoming due to narrow optimum control band of the passive isolation system, and thus to provide optimal control for different seismic excitations in a wider frequency range. It shows that, even under super large earthquakes, the structure still exhibits the ability to maintain overall stability performance.


2020 ◽  
Vol 6 (2) ◽  
pp. 52
Author(s):  
Muhammet Yurdakul ◽  
Mehmet Burak Yıldız

Base isolation system with lead rubber bearing (LRB) is commonly used to prevent structure against to damage of earthquake. Design of LRB system is detailed in this study. The isolated building with LRB design according to Uniform Building Code (UBC-97) and fixed building were examined. The six-storey building with LRB and fixed building were modelled in SAP2000 with the same dynamic loads. The relative floor displacement and internal forces of the seismic isolated and fixed building are compared. In addition, transverse and longitudinal reinforcement of any axis of seismic isolated and fixed building are compared. Analyse results showed that effectiveness of using seismic isolation system on building. The weight of longitudinal and transverse reinforcement of isolated building is smaller than fixed building about 36%, 40% respectively.


2018 ◽  
Vol 2018 ◽  
pp. 1-15
Author(s):  
Xueyuan Yan ◽  
Weihong Chen ◽  
Shen Shi ◽  
Xuan Wang

A typical megaframe structure has a high lateral stiffness and is excellent for high-rise structures. However, this high stiffness can lead to poor seismic response of a structure. Seismic isolation technology is a mature and cheap vibration control method that is used for vibration reduction in megaframes. This paper introduces a megaframe structure based on substructure combined isolation. The structure consists of two parts. The main body is a megaframe, and the substructure is the subframe with the combined isolation layer arranged at the bottom of the subframe. The seismic performance of this structure system was evaluated by performing shaking table tests of two megaframe model structures. The responses of the deformation, acceleration, and shear of the structure were measured. The dynamic behaviors of the structure with or without the combined isolation layer when exposed to single and bidirectional near-fault and far-fault ground motions with different peak values were investigated. The results showed that the combined isolation layer can reduce the bidirectional seismic response of the main frame and subframe. The acceleration, base shear, and displacement responses had similar vibration reduction trends for the two model structures, and the structural responses under bidirectional earthquake were generally greater than that under a single directional earthquake. The near-fault pulse effect increased the seismic response of the structure. The increase of the predominant period of ground motion also increased the seismic response of the structure.


Sign in / Sign up

Export Citation Format

Share Document