scholarly journals Direct Detection of T- and B-Memory Lymphocytes by ImmunoSpot® Assays Reveals HCMV Exposure that Serum Antibodies Fail to Identify

Cells ◽  
2018 ◽  
Vol 7 (5) ◽  
pp. 45 ◽  
Author(s):  
Fredrik Terlutter ◽  
Richard Caspell ◽  
Tobias Nowacki ◽  
Alexander Lehmann ◽  
Ruliang Li ◽  
...  
1997 ◽  
Vol 161 ◽  
pp. 299-311 ◽  
Author(s):  
Jean Marie Mariotti ◽  
Alain Léger ◽  
Bertrand Mennesson ◽  
Marc Ollivier

AbstractIndirect methods of detection of exo-planets (by radial velocity, astrometry, occultations,...) have revealed recently the first cases of exo-planets, and will in the near future expand our knowledge of these systems. They will provide statistical informations on the dynamical parameters: semi-major axis, eccentricities, inclinations,... But the physical nature of these planets will remain mostly unknown. Only for the larger ones (exo-Jupiters), an estimate of the mass will be accessible. To characterize in more details Earth-like exo-planets, direct detection (i.e., direct observation of photons from the planet) is required. This is a much more challenging observational program. The exo-planets are extremely faint with respect to their star: the contrast ratio is about 10−10at visible wavelengths. Also the angular size of the apparent orbit is small, typically 0.1 second of arc. While the first point calls for observations in the infrared (where the contrast goes up to 10−7) and with a coronograph, the latter implies using an interferometer. Several space projects combining these techniques have been recently proposed. They aim at surveying a few hundreds of nearby single solar-like stars in search for Earth-like planets, and at performing a low resolution spectroscopic analysis of their infrared emission in order to reveal the presence in the atmosphere of the planet of CO H2O and O3. The latter is a good tracer of the presence of oxygen which could be, like on our Earth, released by biological activity. Although extremely ambitious, these projects could be realized using space technology either already available or in development for others missions. They could be built and launched during the first decades on the next century.


2001 ◽  
Vol 120 (5) ◽  
pp. A492-A493 ◽  
Author(s):  
E HAINDL ◽  
H BENESCH ◽  
A FINCK ◽  
V MUEHISTEIN ◽  
A LEODOLTER ◽  
...  

1996 ◽  
Vol 76 (06) ◽  
pp. 1020-1029 ◽  
Author(s):  
Laurent Macchi ◽  
Gisèle Clofent-Sanchez ◽  
Gérald Marit ◽  
Claude Bihour ◽  
Catherine Durrieu-Jais ◽  
...  

SummaryIn idiopathic thrombocytopenic purpura (ITP), autoantibodies reacting with antigens on the platelet membrane bring about accelerated platelet destruction. We now report PAICA (“Platelet-Associated IgG Characterization Assay”), a method for detecting autoantibodies bound to specific membrane glycoproteins in total platelet lysates. This monoclonal antibody (MAb) capture assay takes into account the fact that antibodies on circulating platelets may be translocated to internal pools as well as being on the surface. A total of twenty ITP patients were examined by PAICA, and the results compared with those obtained by measuring (i) serum antibodies bound to paraformaldehyde-fixed control platelets by ELISA, (ii) IgG bound to the surface of the patient’s own platelets by flow cytometry (PSIgG), (iii) total platelet-associated IgG (PAIgG) by ELISA and (iv) serum antibodies reacting with control platelets by MAIPA (“Monoclonal Antibody-specific Immobilization of Platelet Antigens”). Of twelve patients with elevated PAIgG, nine had increased PSIgG yet eleven reacted positively in PAICA. Of these, eight possessed antibodies directed against GP Ilb-IIIa, two against GP Ib-IX and one patient possessed antibodies directed against GP Ilb-IIIa and GP Ia-IIa respectively. Only seven of the patients possessed serum antibodies detectable by MAIPA. PAICA was also able to detect platelet-associated c7E3 (the chimeric form of Fab fragments of the MAb 7E3) following its infusion during antithrombotic therapy, when it proved more sensitive over a seven-day period than a MAIPA assay adapted for assessing surface-bound antibody. We propose that PAICA provides added sensitivity to the detection of platelet-associated antibodies in immune thrombocytopenias or following therapy with humanized MAbs.


1996 ◽  
Vol 76 (02) ◽  
pp. 277-278 ◽  
Author(s):  
Masaru Ido ◽  
Tatsuya Hayashi ◽  
Junji Nishioka ◽  
Masazumi Itoh ◽  
Hiroyuki Minoura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document