scholarly journals Simultaneous Hydrolysis and Detection of Organophosphate by Benzimidazole Containing Ligand-Based Zinc(II) Complexes

Crystals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 714
Author(s):  
Gaber A. M. Mersal ◽  
Hamdy S. El-Sheshtawy ◽  
Mohammed A. Amin ◽  
Nasser Y. Mostafa ◽  
Amine Mezni ◽  
...  

The agricultural use of organophosphorus pesticides is a widespread practice with significant advantages in crop health and product yield. An undesirable consequence is the contamination of soil and groundwater by these neurotoxins resulting from over application and run-off. Here, we design and synthesize the mononuclear zinc(II) complexes, namely, [Zn(AMB)2Cl](ClO4) 1 and [Zn(AMB)2(OH)](ClO4) 2 (AMB = 2-aminomethylbenzimidazole), as artificial catalysts inspired by phosphotriesterase (PTE) for the hydrolysis of organophosphorus compounds (OPs) and simultaneously detect the organophosphate pesticides such as fenitrothion and parathion. Spectral and DFT (B3LYP/Lanl2DZ) calculations revealed that complexes 1 and 2 have a square-pyramidal environment around zinc(II) centers with coordination chromophores of ZnN4Cl and ZnN4O, respectively. Both 1 and 2 were used as a modifier in the construction of a biomimetic sensor for the determination of toxic OPs, fenitrothion and parathion, in phosphate buffer by square wave voltammetry. The hydrolysis of OPs using 1 or 2 generates p-nitrophenol, which is subsequently oxidized at the surface of the modified carbon past electrode. The catalytic activity of 2 was higher than 1, which is attributed to the higher electronegativity of the former. The oxidation peak potentials of p-nitrophenol were obtained at +0.97 V (vs. Ag/AgCl) using cyclic voltammetry (CV) and +0.88 V (vs. Ag/AgCl) using square wave voltammetry. Several parameters were investigated to evaluate the performance of the biomimetic sensor obtained after the incorporation of zinc(II) complex 1 and 2 on a carbon paste electrode (CPE). The calibration curve showed a linear response ranging between 1.0 μM (0.29 ppm) and 5.5 μM (1.6 ppm) for fenitrothion and 1.0 μM (0.28 ppm) and 0.1 μM (0.028 ppm) for parathion with a limit of detection (LOD) of 0.08 μM (0.022 ppm) and 0.51 μM (0.149 ppm) for fenitrothion and parathion, respectively. The obtained results clearly demonstrated that the CPE modified by 1 and 2 has a remarkable electrocatalytic activity towards the hydrolysis of OPs under optimal conditions.

2020 ◽  
Vol 10 (4) ◽  
pp. 361-371
Author(s):  
Bruno Ferreira ◽  
Leandro Oka Duarte ◽  
Érica Naomi Oiye ◽  
Maria Fernanda Muzetti Ribeiro ◽  
Juliana Midori Toia Katayama ◽  
...  

The consequences of consuming and commercializing illicit drugs including cocaine, con­stitute a serious problem for authorities and the whole society. Cocaine is usually identified in the laboratory conditions by chromatographic or spectroscopic methods. Electro­che­mical techniques have also gained prominence because they are fast and easy to use, have many applications, and provide reproducible and reliable results. Therefore, in the present study, a voltammetric method was developed to detect freebase cocaine using carbon paste electrode and methanol as the main cocaine solvent. The developed method was applied to detect cocaine in the artificial saliva by the square wave voltammetry (SWV). The current values increased linearly with the concentration of cocaine, which afforded construction of the analytical curve. The limit of detection (LoD) and the limit of quantify­cation (LoQ) were determined as 0.90 µg/mL and 2.41 µg/mL, respectively. For compa­rison purposes, HPLC-DAD chromatographic method was also applied to detect cocaine. The corresponding analytical curve gave LoD = 0.043 µg/mL and LoQ = 0.130 µg/mL. Although showing better analytical results, HPLC-DAD method could not detect cocaine in saliva samples without previous treatment, what makes the electrochemical method much more attractive for this type of detection.


2005 ◽  
Vol 70 (3) ◽  
pp. 292-304 ◽  
Author(s):  
Natalija German ◽  
Saulius Armalis ◽  
Jiří Zima ◽  
Jiří Barek

Square wave voltammetry and differential pulse voltammetry have been used for the determination of 2-acetamidofluorene and fluoren-9-ol using carbon paste electrodes, following the study of the influence of the carbon paste composition on the voltammetric signals of the analytes. The methods are based on the oxidation of the above compounds and they include adsorptive accumulation of the analyte on the surface of the working electrode. The limit of detection was 1 μmol l-1for fluoren-9-ol in a medium of 0.1 M H2SO4, and 40 nmol l-1for 2-acetamidofluorene in Britton-Robinson buffer (pH 7).


2020 ◽  
Vol 18 (11) ◽  
pp. 793-800
Author(s):  
Mahsa JaFari-Pouyani ◽  
Samineh Kaki ◽  
Arash Babakhanian

This study focuses on the compatibility of square wave voltammetry technique with new modified graphite pencil electrode to quantify Oxytocin. Ni-Nano particles and 1,5-diphenylcarbazide modifiers were quickly electro-deposited by cyclic voltammetry sweeping technique on the bare surface of a graphite pencil electrode. The electrochemical and morphological assessments were accomplished with cyclic voltammetry, square wave voltammetry and scanning electron microscopy techniques. The proposed electrochemical sensor revealed a good electro catalytic response to Oxytocin concerning the parameters α = 0.42, log Ks =3.44 and Γ = 8.72×10−10 in the optimized pH of 4 and the working potential of about 0.35 V. The new sensor also exhibited a linear response to Oxytocin over the concentration range of 125 to 350 nmolL−1 with the limit of detection of 41.53 nmolL−1. Moreover, the applicability of the proposed sensor was successfully examined and it became usable to determine Oxytocin accurately and precisely in real samples such as human blood serum sample without any serious side interference.


Author(s):  
İsmail Murat Palabıyık ◽  
Aysegul Dogan ◽  
İncilay Süslü

Background: Hypertension is one of the most important health problems in the world and irbesartan and amlodipine are used in combination in various dosages for the treatment of high blood pressure. Objective: The aim of this study is to develop a fast, easy, sensitive, accurate, and precise square-wave voltammetry method for simultaneous determination of irbesartan and amlodipine besylate from pharmaceutical formulations at a hanging mercury drop electrode. Methods: In the applied method, since both active substances gave a peak at different potentials, no interference occurred between them. In optimization studies Britton-Robinson buffer of pH 8.0 was chosen, in which the most appropriate peak shape and maximum peak current were observed. At the same time, as a result of instrumental parameter optimization to obtain reproducible results, 6 mV for scan increment, 30 mV for pulse amplitude, and 50 Hz for frequency were found suitable. Results: As a result of the calibration studies of the optimized method, linear working ranges were determined as 1.00-13.08 µg mL-1 for irbesartan and 5.83-16.51 µg mL-1 for amlodipine besylate. Limit of detection and limit of quantitation values were respectively calculated as 0.63 and 1.00 µg mL-1 for irbesartan and 0.50 and 1.98 µg mL-1 for amlodipine besylate. The results of precision values (RSD) ranged from 0.67% to 2.31% for irbesartan and 0.65% to 1.49% for amlodipine besylate. Accuracy values were calculated as -0.15% to 1.63% for irbesartan and -0.07% to 3.78% for amlodipine besylate. The results obtained from the recovery studies ranged from 101.05% to 102.78% and from 98.88% to 102.20% for amlodipine besylate and irbesartan, respectively. Conclusion: After the validation studies of the developed method were carried out, it was successfully applied to pharmaceutical formulations containing these active substances.


2008 ◽  
Vol 2008 ◽  
pp. 1-5 ◽  
Author(s):  
Changyan Shi ◽  
Shaoai Xie ◽  
Jinping Jia

A new method of indirect determination ofCu2+was developed based on square-wave voltammetry by the oxidation of iodide in organic solvent at the liquid/liquid (L/L) interface. The limit of detection for the determination ofCu2+in this method was found to be5×10−4 mol/L, and the concentration ranged up to1×10−2 mol/L gave a linear limiting current versus concentration response. For the same simulated wastewater, this method showed high accuracy compared with the result tested by sodium diethyldithiocarbamate extraction spectrophotometry. This approach could be applied to the indirect determination of the oxidative heavy metals in the industrial wastewater.


2006 ◽  
Vol 31 (4) ◽  
pp. 59-62 ◽  
Author(s):  
P. Cervini ◽  
E.T.G. Cavalheiro

In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.


Sign in / Sign up

Export Citation Format

Share Document