scholarly journals Feasibility and Reproducibility of Left Atrium Measurements Using Different Three-Dimensional Echocardiographic Modalities

Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1043
Author(s):  
Andreea Motoc ◽  
Bram Roosens ◽  
Esther Scheirlynck ◽  
Kaoru Tanaka ◽  
Maria Luiza Luchian ◽  
...  

Left atrium (LA) volume is a biomarker of cardiovascular outcomes. Three-dimensional echocardiography (3DE) provides an accurate LA evaluation, but data regarding the optimal 3DE method is scarce. We assessed the feasibility and reproducibility of LA measurements using different 3DE methods. One hundred and ninety-four patients were prospectively analyzed. Conventional 3DE and two semi-automatic 3DE algorithms (Tomtec™ and Dynamic Heart Model (DHM)) were used in 110 patients. Intra- and interobserver reproducibility and intervendor comparison were performed in additional patients’ subsets. Forty patients underwent cardiac magnetic resonance (CMR). Feasibility was 100% for Tomtec, 98.2% for DHM, and 72.8% for conventional 3DE. Tomtec volumes were higher than 3DE and DHM (p < 0.001). Reproducibility was better for DHM (intraobserver LA maximum volume (LAmax) ICC 0.99 (95% CI 1.0–0.99), LA minimum volume (LAmin) 0.98 (95% CI 0.95–0.99), LApreA 0.96 (95% CI 0.91–0.98); interobserver LAmax ICC 0.98 (95% CI 0.96–0.99), LAmin 0.99 (95% CI 0.99–1.00), and LApreA 0.97 (95% CI 0.94–0.99)). Intervendor comparison showed differences between left ventricle (LV) software adapted for LA (p < 0.001). Tomtec underestimated the least LA volumes compared to CMR. These findings emphasize that dedicated software should be used for LA assessment, for consistent clinical longitudinal follow-up and research.

2020 ◽  
Vol 61 (9) ◽  
pp. 1176-1185
Author(s):  
Hanaa MM Abdelaziz ◽  
Ahmed M Tawfik ◽  
Ayman A Abd-Elsamad ◽  
Sherif A Sakr ◽  
Abdulsalam M Algamal

Background The experience with cardiac magnetic resonance (CMR) in mitral stenosis (MS) is limited in contrast to mitral regurgitation. Purpose To compare CMR versus 2D and 3D transthoracic (TTE) and 3D transesophgeal (TEE) echocardiography in assessment of rheumatic MS before and after percutaneous balloon mitral valvuloplasty (PBMV). Material and Methods Twenty consecutive symptomatic patients with MS were evaluated prospectively and independently by CMR, TTE, and TEE pre-PBMV, and by CMR and TTE post-PBMV. Mitral valve area (MVA) was assessed by CMR planimetry, TTE and TEE planimetry, and pressure half time (PHT). Further assessment included trans-mitral velocity, mitral regurgitation (MR), and left atrial (LA) volume. Results PBMV was successful in 18 patients and failed in two patients (one with MVA <1.5 cm2, one developed severe MR). Pre-PBMV and MVA by CMR, 2D TTE, biplane, 3D TTE, 3D TEE, and PHT were 1.16, 1.16, 1.10, 1.02, 1.05, and 0.99 cm2, respectively. Post-PBMV, a significant increase in MVA was observed (2.15, 2.06, 2.07, 2.04, and 2.03 cm2, respectively). High agreement was observed between CMR and echocardiography before and after PBMV, except for PHT method. CMR significantly underestimated trans-mitral velocity and gradients compared to echocardiography (P<0.001). Before PBMV, mild MR was observed in 11, 12, and 19 patients by 2D TTE, 3D TTE, and CMR. After PBMV, MR was observed in all patients (19 mild, one severe) by all modalities. Echocardiography significantly underestimated LA volume compared to CMR (P<0.001). LA volume decreased significantly after PBMV (P<0.001). Conclusion CMR provides comprehensive assessment of several parameters in MS patients before and after intervention. Agreement with echocardiography is acceptable.


Sign in / Sign up

Export Citation Format

Share Document