scholarly journals Low Voltage Ride Through Controller for a Multi-Machine Power System Using a Unified Interphase Power Controller

Electronics ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 585
Author(s):  
Atoosa Majlesi ◽  
Mohammad Reza Miveh ◽  
Ali Asghar Ghadimi ◽  
Akhtar Kalam

In recent years, grid-connected photovoltaic (PV) power generations have become the most extensively used energy resource among other types of renewable energies. Increasing integration of PV sources into the power network and their dynamic performances under fault conditions is an important issue for grid code requirements. In this paper, a PV source as a unified interphase power controller (UIPC) is used to enhance the low voltage ride through (LVRT) and transient stability of a multi-machine power system. The suggested PV-based UIPC consists of two series voltage inverters and a parallel inverter. The UIPC injects the required active and reactive power to prevent voltage drop under grid fault conditions. Accordingly, a dynamic control system is designed based on proportional-integral (PI) controllers for the PV-based UIPC to operate in both normal and fault conditions. Simulations are done using Matlab/Simulink software, and the performance of the PV-based UIPC is compared with the conventional unified power flow controller (UPFC). The results of this study indicate the more favorable impact of the PV-based UIPC on the system compared to UPFC in improving LVRT capabilities and transient stability.

2014 ◽  
Vol 986-987 ◽  
pp. 1296-1299
Author(s):  
Li Juan Chen ◽  
Zhi Jie Wang ◽  
Xin Xia Su

When the grid voltage dips, in order to keep DFIG connected to grid and accelerate the recovery of grid voltage, reactive power compensation STATCOM is adapted to provide reactive power for grid, and crowbar circuit is installed to protect the converter of DIFG. Transient stability of power system is improved and the low voltage ride through is realized.


Author(s):  
Anuj Singh ◽  
Dr. Sandeep Sharma ◽  
Karan Sharma ◽  
Flansha Jain ◽  
Shreyanshu Kumar Jena

A Power System is actually a vast system that requires an outstanding plan for maintaining the continual flow of electricity. When a fault occurs at the power system, number of difficulties arises because of transients in system. so to attenuate these transients, power electronics based devices like FACTS are utilized. A unified power flow controller (UPFC) is one among different power electronics controller which can dispense VAR compensation, line impedance control and phase shifting. The thought is to see potential of UPFC to require care of active and reactive power movement within the compensated line (including UPFC) and to shrink the falloff of the bus voltage in case of grounding fault within the cable. power system block consisting of simulink is used for numerical analysis. Simulation outcomes from MATLAB reflects major improvement in the overall system’s behaviour with UPFC in sustain the voltage and power flow even under severe line faults by proper injection of series voltage into the cable at the point of connection. outcomes shows how the UPFC contributes effectively to a faster regaining of the power system to the pre-fault conditions.


Author(s):  
Adewale Obaro ◽  
Isaiah Adebayo

The continuous increase in power demand and huge power losses in modern power systems have been a growing concern to power utilities. Such phenomenon often results in epileptic power supply, power system instability, supply fluctuations and security problems in many parts of the globe. Identification of suitable places for the installation of reactive power compensators to minimize voltage drop and system power losses in a power system becomes imperative. In this paper, the Newton-Raphson iterative method was used for the power flow solution of the 28 bus Nigerian 330KV grid system. The Generalized Unified Power flow Controller (GUPFC) is installed at identified weak load buses of the Nigerian 28-bus power system to reduce the losses and voltage drop of the system. A comparative analysis of the GUPFC with Load Tap Changing Transformers (LTCT) is also performed. Result obtained shows that the GUPFC can largely (effectively) improve the system power stability and selectively balance the power flow of multi-lines power flows when placed at identified weak buses compared with LTCT.  Thus, GUPFC can be used to reduce overall power losses along transmission lines as well as improve stability overall reliability of the power grid system.


Author(s):  
Million Alemayehu Bedasso* ◽  
R. Srinu Naik

In order to eliminate active and reactive power losses in the power system, this paper proposes TOPSIS and DE algorithm for determining the best location and parameter settings for the Unified Power Flow Controller (UPFC). To mitigate power losses, the best UPFC allocation can be achieved by re-dispatching load flows in power systems. The cost of incorporating UPFC into the power system. As a consequence, the proposed objective feature in this paper was created to address this problem. The IEEE 14-bus and IEEE 30-bus systems were used as case studies in the MATLAB simulations. When compared to particle swarm optimization, the results show that DE is a simple to use, reliable, and efficient optimization technique than (PSO). The network's active and reactive power losses can be significantly reduced by putting UPFC in the optimum position determined by TOPSIS ranking method.


Now days’ electrical power requirement has enlarged expanding as expansion & restructuring of electrical power system (PS) for generation & transmission in power sector is critically limited due to current resources & environmental circumstances. As outcome, approximately of corridors of power transmission overhead lines are greatly loaded & congested. Also major issue of power system voltage stability becomes power transfer restricted and capability issue. A Modern power electronics technology FATCS considered device Static Synchronous Series Compensator (SSSC) is VSC demanded series FACTS equipment. Unified power flow controller (UPFC) is to manage power flow (PF), voltage magnitude & phase angle. In this research paper suggested to maintain voltage magnitude as well as PF of faulty lines. The consequence of mutation of PS parameters like voltage, phase angle, active power, reactive power, & overall power factor with & without SSSC & UPFC have also incorporated. Assessment of PS safety is essential in society to expand customs to sustain system functions when one or more components fail. A PS is "secure" when it can defy loss of one or more ingredients & still go on working without major problems. The Contingency event investigation technique is taken to identify electrical node PF in faulty transmission lines (TL). The Performance of PS has been tested on IEEE 14-Bus System.


Author(s):  
Mahmood Khalid Zarkani ◽  
Ahmed Sahib Tukkee ◽  
Mohammed Jasim Alali

<p>The rapid and enormous growths of the power electronics industries have made the flexible AC transmission system (FACTS) devices efficient and viable for utility application to increase power system operation controllability as well as flexibility. This research work presents the application of an evolutionary algorithm namely differential evolution (DE) approach to optimize the location and size of three main types of FACTS devices in order to minimize the power system losses as well as improving the network voltage profile. The utilized system has been reactively loaded beginning from the base to 150% and the system performance is analyzed with and without FACTS devices in order to confirm its importance within the power system. Thyristor controlled series capacitor (TCSC), unified power flow controller (UPFC) and static var compensator (SVC) are used in this research work to monitor the active and reactive power of the carried out system. The adopted algorithm has been examined on IEEE 30-bus test system. The obtained research findings are given with appropriate discussion and considered as quite encouraging that will be valuable in electrical grid restructuring.</p>


2014 ◽  
Vol 644-650 ◽  
pp. 3509-3514
Author(s):  
Jian Hua Zhang ◽  
Hao Ran Shen ◽  
Lei Ding ◽  
Chun Lei Dai

In order to analyze the control strategy of the low voltage ride through (LVRT) of DFIG during the asymmetric voltage sag, it is necessary to analyze the transient performance of a DFIG during the asymmetric voltage sag. In this paper, analyzed the influence of the asymmetric grid voltage to DFIG and the analysis method of the asymmetric voltage sag, and on the basis of positive and negative sequence mathematical model, analyzed the composition of stator output active and reactive power under the condition of asymmetric grid voltage. And built a DFIG asymmetric voltage drop simulation model of 1.5MW in MATLAB/Simulink, the simulation results shows that the stator voltage, current, active power and reactive power all present a double frequency ripple during the asymmetric voltage sag, consistent with theoretical analysis. It can provide theoretical basis for double-fed motor control strategy of asymmetric LVRT.


Sign in / Sign up