scholarly journals Power System Security with Contingency Technique by using SSSC & UPFC

Now days’ electrical power requirement has enlarged expanding as expansion & restructuring of electrical power system (PS) for generation & transmission in power sector is critically limited due to current resources & environmental circumstances. As outcome, approximately of corridors of power transmission overhead lines are greatly loaded & congested. Also major issue of power system voltage stability becomes power transfer restricted and capability issue. A Modern power electronics technology FATCS considered device Static Synchronous Series Compensator (SSSC) is VSC demanded series FACTS equipment. Unified power flow controller (UPFC) is to manage power flow (PF), voltage magnitude & phase angle. In this research paper suggested to maintain voltage magnitude as well as PF of faulty lines. The consequence of mutation of PS parameters like voltage, phase angle, active power, reactive power, & overall power factor with & without SSSC & UPFC have also incorporated. Assessment of PS safety is essential in society to expand customs to sustain system functions when one or more components fail. A PS is "secure" when it can defy loss of one or more ingredients & still go on working without major problems. The Contingency event investigation technique is taken to identify electrical node PF in faulty transmission lines (TL). The Performance of PS has been tested on IEEE 14-Bus System.

Power system is a largely inter connected network, due to this interconnection some of the lines may get over loaded and voltage collapse will occur , hence these lines are called weak lines, this causes serious voltage instability at the particular lines of the power system. The improvement of stability will achieve by controlling the reactive power flow. The Flexible Alternating Current Transmission Systems (FACTS) devices have been proposed to effectively controlling the power flow in the lines and to regulate the bus voltages in electrical power systems, resulting in an increased power transfer capability, low system losses and improved stability. In FACTS devices the Unified Power Flow Controller (UPFC) is one of the most promising device for power flow control. It can either simultaneously or selectively control both real and reactive flow and bus voltage. UPFC is a combination of shunt and series compensating devices. Optimal location of UPFC is determined based on Voltage Stability Index (VSI). GA and PSO techniques are used to set the parameters of UPFC [6]. The objective function formulated here is fitness function, which has to be maximized for net saving. The results obtained using PSO on IEEE 14 Bus is compared with that of results obtained using GA, to show the validity of the proposed techniques and for comparison purposes


2014 ◽  
Vol 573 ◽  
pp. 310-316 ◽  
Author(s):  
K. Poun Raj ◽  
V. Raja Sekaren ◽  
S. Selvaperumal ◽  
N. Mageswari

– The unified power flow controller (UPFC) is the most versatile and complex power electronic equipment that has emerged as the indispensable equipment for the control and optimization of power flow in electrical power transmission system. In this manuscript is investigated the control of real and reactive power flow through a transmission line with the use of UPFC at the sending end. Computer simulation using MATLAB Simulink is done and the behavior of the UPFC is studied. In the UPFC based control of transmission line parameter control systems, it is observed that whenever the SSSC sources some real power into the transmission line it is manifested as a voltage drop across the DC link. Reactive power demand is indicated as fall in the bus bar AC voltage. The fall of the DC link voltage is an indication of real power demand from the receiving end. Similarly a fall of the bus bar AC voltage is an indication of reactive power demand from the receiving end. Fuzzy Logic and PI controllers are used in this works, the control of DC voltage, AC voltage and power transfer.


2020 ◽  
Vol 26 (2) ◽  
pp. 176-192
Author(s):  
Sana K. Abd al hassan ◽  
Firas Mohammed Tuaimah

Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of the voltage can be varied independently. The steady state model of UPFC has been adopted on IEEE-30 bus test system and simulated using MATLAB programming language. Newton Raphson (NR) numerical analysis method has been used for solving the load flow of the system. The practical part has been solved through Power System Simulation for Engineers (PSS\E) software Version 32.0. The Comparative results between the experimental and practical parts obtained from adopting the UPFC where too close and almost the same under different loading conditions, which are (5%, 10%, 15% and 20%) of the total load.


2018 ◽  
Vol 7 (3) ◽  
pp. 1656 ◽  
Author(s):  
Nabil A. Hussein ◽  
Ayamn A. Eisa ◽  
Hassan M. Mahmoud ◽  
Safy A. Shehata ◽  
El-Saeed A. Othman

Flexible AC Transmission Systems (FACTS) have been proposed in the late 1980s to meet and provide the electrical power system requirements. FACTS are used to control the power flow and to improve the power system stability. Interline power flow controller (IPFC) is a versatile device in the FACTS family of controllers and one of its latest generations which has the ability to simultaneously control the power flow in two or multiple transmission lines. This paper is tackling the IPFC performance in power systems; it aims to discuss the availability to define a known scenario for the IPFC performance in different systems. An introduction supported with brief review on IPFC, IPFC principle of operation and IPFC mathematical model are also introduced. IEEE 14-bus and 30-bus systems have chosen as a test power systems to support the behavior study of power system equipped with IPFC device. Three different locations have chosen to give variety of system configurations to give effective performance analysis.  


Author(s):  
CH. CHENGAIAH ◽  
R.V.S. SATYANARAYANA ◽  
G.V. MARUTHESWAR MARUTHESWAR

The power transfer capability of electric transmission lines are usually limited by large signals ability. Economic factors such as the high cost of long lines and revenue from the delivery of additional power gives strong intensive to explore all economically and technically feasible means of raising the stability limit. On the other hand, the development of effective ways to use transmission systems at their maximum thermal capability. Fast progression in the field of power electronics has already started to influence the power industry. This is one direct out come of the concept of FACTS aspects, which has become feasible due to the improvement realized in power electronic devices in principle the FACTS devices should provide fast control of active and reactive power through a transmission line. The UPFC is a member of the FACTS family with very attractive features. This device can independently control many parameters. This device offers an alternative mean to mitigate transmission system oscillations. It is an important question is the selection of the input signals and the adopted control strategy for this device in order to damp power oscillations in an effective and robust manner. The UPFC parameters can be controlled in order to achieve the maximal desire effect in solving first swing stability problem. This problem appears for bulky power transmission systems with long transmission lines. In this paper a MATLAB Simulink Model is considered with UPFC device to evaluate the performance of Electrical Transmission System of 22 kV and 33kV lines. In the simulation study, the UPFC facilitates the real time control and dynamic compensation of AC transmission system. The dynamic simulation is carried out in conjunction with the N-R power flow solution sequence. The updated voltages at each N-R iterative step are interpreted as dynamic variables. The relevant variables are input to the UPFC controllers.


Author(s):  
Anuj Singh ◽  
Dr. Sandeep Sharma ◽  
Karan Sharma ◽  
Flansha Jain ◽  
Shreyanshu Kumar Jena

A Power System is actually a vast system that requires an outstanding plan for maintaining the continual flow of electricity. When a fault occurs at the power system, number of difficulties arises because of transients in system. so to attenuate these transients, power electronics based devices like FACTS are utilized. A unified power flow controller (UPFC) is one among different power electronics controller which can dispense VAR compensation, line impedance control and phase shifting. The thought is to see potential of UPFC to require care of active and reactive power movement within the compensated line (including UPFC) and to shrink the falloff of the bus voltage in case of grounding fault within the cable. power system block consisting of simulink is used for numerical analysis. Simulation outcomes from MATLAB reflects major improvement in the overall system’s behaviour with UPFC in sustain the voltage and power flow even under severe line faults by proper injection of series voltage into the cable at the point of connection. outcomes shows how the UPFC contributes effectively to a faster regaining of the power system to the pre-fault conditions.