scholarly journals Harmonic Resonance Identification and Mitigation in Power System Using Modal Analysis

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4017
Author(s):  
Jure Lokar ◽  
Janja Dolenc ◽  
Boštjan Blažič ◽  
Leopold Herman

Due to a rising share of power electronic devices in power networks and the consequent rise in harmonic distortion, impedance resonances are an important issue. Nowadays, the frequency scan method is used for resonance phenomena identification and analysis. The main disadvantage of the method is its inability to decouple different resonance phenomena. This means that the method is also unable to provide sufficient information about the effects that the parameters of network elements have on different resonance phenomena. Furthermore, it was also noted that despite the fact that the harmonic resonance mode analysis is well described in the literature, there is a lack of systematic approach to the analysis procedure. Thus the main objective of this paper is to address this disadvantage and to propose a systematic approach to harmonic resonance analysis and mitigation, utilizing modal analysis. In the first part of the paper, dominant network nodes in terms of resonance amplification of harmonics are determined. This is done by analysis of the eigenvalues of the network admittance matrix. Using the eigenvalue analysis results, key parameters of network elements involved in a specific resonance are determined next. This is performed by calculating the critical mode (i.e., the mode that experiences resonance) sensitivity coefficients with respect to network parameters. In the second part of the paper, the procedure for modal resonance frequency shift is presented. The shift is performed by changing the value of a selected parameter so that the modal resonance frequency matches the desired resonance frequency value. The parameter value is calculated with the Newton–Rhapson method. Presented analysis considers both parallel and series resonances. The effectiveness of the proposed method is demonstrated on an actual industrial-network model.

2021 ◽  
pp. 0309524X2110379
Author(s):  
Yue Wang ◽  
Yonggang Li ◽  
Yinan Yang ◽  
Binyuan Wu ◽  
Qiyu Liu ◽  
...  

This paper presents a gray-box harmonic resonance frequency identification method of multiple-inverter-fed power system, which enables modal analysis oriented to system designers based on only frequency response data provided by diverse vendors or measured by frequency scanning. First, admittance transfer functions of all grid-connected inverters (GCIs) are fitted using Matrix Pencil Method-Vector Fitting (MPM-VF) combined method. Then, node admittance matrix (NAM) is formed according to the topology of whole system. Finally, harmonic resonance frequency along with changes in number of GCIs are identified by NAM-based modal analysis (MA). The proposed gray-box identification method is implemented in a typical multiple-inverter-fed power system. The correctness of harmonic resonance frequency identification results and the effectiveness of the presented method are verified by simulation results obtained in Matlab/Simulink platform and OPAL-RT digital real-time simulation platform. Based on the identification results, a more stable and better power quality multiple-inverter-fed power system can be built by system designers though avoiding the appearance of harmonic sources with corresponding resonance frequency.


2013 ◽  
Vol 765-767 ◽  
pp. 92-95
Author(s):  
Yun Dian Zhang ◽  
Liang Fang ◽  
Zhi Ping Lu ◽  
Jia Ying Yu

The ultrasonic cutting of composite materials has the advantages such as high processing efficiency, high precision and non-pollution. The working principle of ultrasonic cutting is studied. The structure of circular tool is designed. The differential equation of tool frequency is established. The resonance frequency of tool is solved. Modal analysis is conducted for circular tool through ANSYS and the results are compared through tests.


Author(s):  
Koteswara Rao Uyyuru ◽  
Mahesh Kumar Mishra

In this paper, the perfect harmonic cancellation (PHC), unity power factor (UPF) control strategies of distribution static compensator (DSTATCOM) are compared along with a newly proposed control strategy. In the proposed strategy, to get the best power factor, the conductance factors for the compensated load are evaluated for a specified source current total harmonic distortion (THD) limit. The performance of this method along with perfect harmonic cancellation (PHC) and unity power factor (UPF) strategies is evaluated on a distribution system model developed using PSCAD 4.2.1. In the distribution system, harmonic resonance is one of the prime factors for the harmonic propagation. Hence, in damping the harmonic resonance, selection of an appropriate control strategy for the DSTATCOM is crucial and this is verified with a detailed study. The simulation results are presented to show the performance of these strategies in load compensation and damping the harmonic propagation in the distribution system.


2004 ◽  
Vol 150 (3) ◽  
pp. 26-35 ◽  
Author(s):  
Tatsuhito Nakajima ◽  
Hirokazu Suzuki ◽  
Koji Temma ◽  
Isao Iyoda

Sign in / Sign up

Export Citation Format

Share Document