scholarly journals A Sensitivity Matrix Approach Using Two-Stage Optimization for Voltage Regulation of LV Networks with High PV Penetration

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6596
Author(s):  
A.S. Jameel Hassan ◽  
Umar Marikkar ◽  
G.W. Kasun Prabhath ◽  
Aranee Balachandran ◽  
W.G. Chaminda Bandara ◽  
...  

The occurrence of voltage violations is a major deterrent for absorbing more rooftop solar power into smart Low-Voltage Distribution Grids (LVDGs). Recent studies have focused on decentralized control methods to solve this problem due to the high computational time in performing load flows in centralized control techniques. To address this issue, a novel sensitivity matrix was developed to estimate the voltages of the network by replacing load flow simulations. In this paper, a Centralized Active, Reactive Power Management System (CARPMS) is proposed to optimally utilize the reactive power capability of smart Photovoltaic (PV) inverters with minimal active power curtailment to mitigate the voltage violation problem. The developed sensitivity matrix is able to reduce the time consumed by 55.1% compared to load flow simulations, enabling near-real-time control optimization. Given the large solution space of power systems, a novel two-stage optimization is proposed, where the solution space is narrowed down by a Feasible Region Search (FRS) step, followed by Particle Swarm Optimization (PSO). The failure of standalone PSO to converge to a feasible solution for 34% of the scenarios evaluated further validates the necessity of the two-stage optimization using FRS. The performance of the proposed methodology was analysed in comparison to the load flow method to demonstrate the accuracy and the capability of the optimization algorithm to mitigate voltage violations in near-real time. The deviations of the mean voltages of the proposed methodology from the load flow method were: 6.5×10−3 p.u for reactive power control using Q-injection, 1.02×10−2 p.u for reactive power control using Q-absorption, and 0 p.u for active power curtailment case.

Author(s):  
Chico Hermanu Brillianto Apribowo ◽  
Oktavian Listiyanto

<p class="Abstract">Demand for electricity is increasing rapidly, the consequence of this is a threat to the stability of the electrical system, one of which is the voltage stability. FACTS or Flexible Alternating Current Transmission System is electronic equipment that is able to regulate electric power transmission that can be used to overcome stability problems. This research will analyze the use of Static Var Compensator (SVC) as one of the equipment from FACTS to overcome the stability of the most critical buses by using the 500 kV Java-Bali electricity system using PSAT. Results from using the power flow method in the 500 kV Java-Bali case show that the total active power generation is 12.144 p.u. and the total reactive power generation is 5.268 p.u. This value is obtained from the total addition of active power generation and reactive power of all plants in the 500 kV Java-Bali system. While the total active power load is worth 12.058 p.u. and the total reactive power load is 4.65 p.u. This value is obtained from the total load on each bus plus the total losses incurred on the line.</p>


Energies ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1327 ◽  
Author(s):  
Thiago Soares ◽  
Ubiratan Bezerra ◽  
Maria Tostes

This paper proposes the development of a three-phase state estimation algorithm, which ensures complete observability for the electric network and a low investment cost for application in typical electric power distribution systems, which usually exhibit low levels of supervision facilities and measurement redundancy. Using the customers´ energy bills to calculate average demands, a three-phase load flow algorithm is run to generate pseudo-measurements of voltage magnitudes, active and reactive power injections, as well as current injections which are used to ensure the electrical network is full-observable, even with measurements available at only one point, the substation-feeder coupling point. The estimation process begins with a load flow solution for the customers´ average demand and uses an adjustment mechanism to track the real-time operating state to calculate the pseudo-measurements successively. Besides estimating the real-time operation state the proposed methodology also generates nontechnical losses estimation for each operation state. The effectiveness of the state estimation procedure is demonstrated by simulation results obtained for the IEEE 13-bus test network and for a real urban feeder.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5922
Author(s):  
Yu Zhang ◽  
Xiaohui Song ◽  
Yong Li ◽  
Zilong Zeng ◽  
Chenchen Yong ◽  
...  

A high proportion of renewable energy connected to the power grid has caused power quality problems. Voltage-sensitive loads are extremely susceptible to voltage fluctuations, causing power system safety issues and economic losses. Considering the uncertainty factor and the time-varying characteristic, a linearized random ZIP model (constant impedance (Z), constant current (I), and constant power (P)) with time-varying characteristics was proposed. In order to improve the voltage quality of the voltage-sensitive loads in the day-here stage in an active distribution network (ADN), a linearized two-stage active and reactive power coordinated stochastic optimization model was established. The day-ahead active and reactive power coordination optimization was to smooth the large voltage fluctuation and develop a reserve plan to eliminate the unbalanced power caused by the prediction error in the day-here optimization. In the day-here real-time redispatch, the voltage was further improved by the continuous reactive power compensation device. Finally, the simulation results on the IEEE-33 bus system showed that the control strategy could better eliminate the unbalanced power caused by the prediction error and obviously improve the voltage of sensitive loads in the real-time stage on the premise of maintaining economic optimality.