scholarly journals Aerosol Release by Healthy People during Speaking: Possible Contribution to the Transmission of SARS-CoV-2

Author(s):  
Thomas Eiche ◽  
Martin Kuster

Our research aimed to review the potential risk of infection by SARS-CoV-2. We used an excerpt of a data set generated in May 2020 for reviewing the SARS-CoV-2 prevention concept of orchestras, singers and actors. People were sampled for droplet release for one-hour activities using a Grimm spectrometer covering a spectrum of 1 to 32 µm diameter. We estimated the number of “quanta” in the exhaled liquid from viral concentrations of 106 to 1011/mL, based on the Human Infective Dose 50 of 218 viral particles. We employed the Wells–Riley equation to estimate the risk of infection in typical meeting rooms for a one-hour meeting of 2, 4 and 6 people observing a 2 m distance. The four participating adults released a mean of 1.28 nLm3 while breathing, 1.68 nL/m3 while speaking normally, and two adults released a mean of 4.44 nL/m3 while talking with a raised voice. The combination of 50% breathing, 45% talking normally and 5% speaking with a raised voice increased the risk of infection above 5% for a one-hour meeting of two people. The result is based on 6 quanta released, corresponding to an initial virus concentration of 1000/nL (109/mL) in the fluid of the upper respiratory tract. Our data confirm the importance of using facemasks in combination with other measures to prevent transmission of SARS-CoV-2 at the workplace.

2008 ◽  
Vol 21 (1) ◽  
pp. 109-112
Author(s):  
Agnieszka Grzegorczyk ◽  
Anna Biernasiuk ◽  
Izabela Mahorowska-Kiciak ◽  
Anna Malm

2020 ◽  
Author(s):  
Wiebke Michel ◽  
Jacqueline Farber ◽  
Milica Dilas ◽  
Ina Tammer ◽  
Jannik Baar ◽  
...  

Objectives: The optimal diagnostic specimen to detect SARS-CoV-2 by PCR in the upper respiratory tract is unclear. Mouthwash fluid has been reported as an alternative to nasopharyngeal and oropharyngeal swabs. We compared mouthwash fluid with a combined oro-nasopharyngeal swab regarding test performance. Methods: We tested asymptomatic persons with a previous diagnosis of COVID-19 and their household contacts. First, a mouthwash (gargling for at least 5 sec) with sterile water was performed. Then, with a single flocked swab the back of the throat and subsequently the nasopharynx were sampled. Samples were inactivated and analysed on a Roche cobas 6800 system with the Roche SARS-CoV-2 test. Results: Of 76 persons, 39 (51%) tested positive for SARS-CoV-2 by oro-nasopharyngeal swab. Mouthwash detected 13 (17%) of these infections but did not detect any additional infection. Samples that were positive in both tests, had lower cycle threshold (Ct)-values for oro-nasopharyngeal samples, indicating a higher virus concentration, compared to samples only positive in oro-nasopharyngeal swabs. Conclusions: Mouthwash is not as sensitive as combined oro-nasopharyngeal swab in detecting upper respiratory tract infection.


Infection ◽  
2021 ◽  
Author(s):  
Wiebke Michel ◽  
Jacqueline Färber ◽  
Milica Dilas ◽  
Hans-Gert Heuft ◽  
Ina Tammer ◽  
...  

Abstract Objectives The optimal diagnostic specimen to detect SARS-CoV-2 by PCR in the upper respiratory tract is unclear. Mouthwash fluid has been reported as an alternative to nasopharyngeal and oropharyngeal swabs. We compared mouthwash fluid with a combined oro-nasopharyngeal swab regarding test performance. Methods In a large refugee facility, we retested individuals with a previous positive test for SARS-CoV-2 and their quarantined close contacts. All individuals were asymptomatic at the time of testing. First, a mouthwash (gargling for at least 5 s) with sterile water was performed. Then, with a single flocked swab the back of the throat and subsequently the nasopharynx were sampled. Samples were inactivated and analysed on a Roche cobas 6800® system with the Roche SARS-CoV-2 test. Results Of 76 individuals, 39 (51%) tested positive for SARS-CoV-2 by oro-nasopharyngeal swab. Mouthwash detected 13 of 76 (17%) infections, but did not detect any additional infection. Samples that were positive in both tests, had lower cycle threshold (Ct)-values for oro-nasopharyngeal samples, indicating a higher virus concentration, compared to samples only positive in oro-nasopharyngeal swabs. Conclusion Mouthwash is not as sensitive as combined oro-nasopharyngeal swab in detecting upper respiratory tract infection.


1970 ◽  
Vol 3 (2) ◽  
pp. 265-276 ◽  
Author(s):  
Jack D. Clemis ◽  
Eugene L. Derlacki

Sign in / Sign up

Export Citation Format

Share Document