scholarly journals Novel High-Power, High Repetition Rate Laser Diode Pump Modules Suitable for High-Energy Class Laser Facilities

Instruments ◽  
2019 ◽  
Vol 3 (3) ◽  
pp. 34
Author(s):  
Marko Hübner ◽  
Ingo Will ◽  
Jörg Körner ◽  
Jürgen Reiter ◽  
Mathias Lenski ◽  
...  

The latest generation of high-energy-class pulsed laser facilities, under construction or planned, such as EuPRAXIA, require reliable pump sources with high power (many kW), brightness (>1 MW/cm2/sr) and electro-optical conversion efficiency (>50%). These new facilities will be operated at high repetition rates (around 100 Hz) and only diode lasers are capable of delivering the necessary performance. Commercial (quasi-continuous wave, QCW) diode laser pulse-pump sources are, however, constructed as low-cost passively cooled stacked arrays that are limited either in brightness, efficiency or repetition rate. Commercial continuous wave diode laser pumps constructed using microchannel coolers (as used in high-value industrial machine tools) can fulfil all requirements, but are typically not preferred, due to their cost and complexity and the challenges of preventing cooler degradation. A custom solution is shown here to fill this gap, using advanced diode lasers in a novel passive side-cooling geometry to realize 100 … 200 Hz pump modules (10%–20% duty cycle) that emit peak power of 6 kW at wavelength = 940 nm. The latest performance of these modules is summarized and compared to literature. We show that a brightness >1 MW/cm2/sr can be efficiently delivered across a wide range of laser pulse conditions with 10% duty cycle (pulse width: 100 µs … 100 ms … cw, repetition rate up to 1 kHz). Furthermore, we describe how these pumps have been used to construct and reliably operate (>109 pulses without degradation) in high-energy-class regenerative and ring amplifiers at the Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie (MBI). We also show first results on 100 Hz pumping of cryogenically cooled solid-state Yb:YAG slab amplifiers, as anticipated for use in the EuPRAXIA laser, and note that peak temperature is disproportionately increased, indicating that improved cooling and more detailed studies are needed.

2021 ◽  
Author(s):  
S. Arslan ◽  
A. Maasdorf ◽  
D. Martin ◽  
S. Kreutzmann ◽  
P. A. Crump

1997 ◽  
Vol 33 (19) ◽  
pp. 1635 ◽  
Author(s):  
D.Z. Garbuzov ◽  
R.J. Menna ◽  
R.U. Martinelli ◽  
J.H. Abeles ◽  
J.C. Connolly

Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 710
Author(s):  
Michał Michalik ◽  
Jacek Szymańczyk ◽  
Michał Stajnke ◽  
Tomasz Ochrymiuk ◽  
Adam Cenian

The paper deals with the medical application of diode-lasers. A short review of medical therapies is presented, taking into account the wavelength applied, continuous wave (cw) or pulsed regimes, and their therapeutic effects. Special attention was paid to the laryngological application of a pulsed diode laser with wavelength 810 nm, and dermatologic applications of a 975 nm laser working at cw and pulsed mode. The efficacy of the laser procedures and a comparison of the pulsed and cw regimes is presented and discussed.


1995 ◽  
Vol 66 (11) ◽  
pp. 5162-5164 ◽  
Author(s):  
Tatsumi Goto ◽  
Koji Kakizaki ◽  
Shigeyuki Takagi ◽  
Noboru Okamoto ◽  
Saburo Sato ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document