scholarly journals Point-of-Care Ultrasound-Guided Protocol to Confirm Central Venous Catheter Placement in Pediatric Patients Undergoing Cardiothoracic Surgery: A Prospective Feasibility Study

2021 ◽  
Vol 10 (24) ◽  
pp. 5971
Author(s):  
Torsten Baehner ◽  
Marc Rohner ◽  
Ingo Heinze ◽  
Ehrenfried Schindler ◽  
Maria Wittmann ◽  
...  

Background: Central venous catheters (CVC) are commonly required for pediatric congenital cardiac surgeries. The current standard for verification of CVC positioning following perioperative insertion is postsurgical radiography. However, incorrect positioning may induce serious complications, including pleural and pericardial effusion, arrhythmias, valvular damage, or incorrect drug release, and point of care diagnostic may prevent these serious consequences. Furthermore, pediatric patients with congenital heart disease receive various radiological procedures. Although relatively low, radiation exposure accumulates over the lifetime, potentially reaching high carcinogenic values in pediatric patients with chronic disease, and therefore needs to be limited. We hypothesized that correct CVC positioning in pediatric patients can be performed quickly and safely by point-of-care ultrasound diagnostic. Methods: We evaluated a point-of-care ultrasound protocol, consistent with the combination of parasternal craniocaudal, parasternal transversal, suprasternal notch, and subcostal probe positions, to verify tip positioning in any of the evaluated views at initial CVC placement in pediatric patients undergoing cardiothoracic surgery for congenital heart disease. Results: Using the combination of the four views, the CVC tip could be identified and positioned in 25 of 27 examinations (92.6%). Correct positioning was confirmed via chest X-ray after the surgery in all cases. Conclusions: In pediatric cardiac patients, point-of-care ultrasound diagnostic may be effective to confirm CVC positioning following initial placement and to reduce radiation exposure.

2015 ◽  
Vol 16 (8) ◽  
pp. 726-732 ◽  
Author(s):  
Brian A. Boe ◽  
Jeffrey D. Zampi ◽  
Sunkyung Yu ◽  
Janet E. Donohue ◽  
Ranjit Aiyagari

2020 ◽  
Vol 4 (2) ◽  
pp. 222-224
Author(s):  
Ashley Rider ◽  
Andrea Dreyfuss ◽  
Roberto Inga

Ebstein’s anomaly is a congenital heart defect that when left untreated can lead to unique physical exam and ultrasound findings. This case describes a patient who presented with dyspnea and was found to have cyanosis, clubbing, and dilation of right-sided chambers on point-of-care ultrasound. The series of images highlights findings in late-stage Ebstein’s anomaly and serves as a springboard for the discussion of the pathophysiology, diagnosis, and treatment of this rare congenital heart disease.


2021 ◽  
Vol 9 ◽  
Author(s):  
Jessica N. Persson ◽  
Jacqueline Holstein ◽  
Lori Silveira ◽  
Aimee Irons ◽  
Taufiek Konrad Rajab ◽  
...  

Purpose: Fluid overload is a common post-operative issue in children following cardiac surgery and is associated with increased morbidity and mortality. There is currently no gold standard for evaluating fluid status. We sought to validate the use of point-of-care ultrasound to measure skin edema in infants and assess the intra- and inter-user variability.Methods: Prospective cohort study of neonates (≤30 d/o) and infants (31 d/o to 12 m/o) undergoing cardiac surgery and neonatal controls. Skin ultrasound was performed on four body sites at baseline and daily post-operatively through post-operative day (POD) 3. Subcutaneous tissue depth was manually measured. Intra- and inter-user variability was assessed using intraclass correlation coefficient (ICC).Results: Fifty control and 22 surgical subjects underwent skin ultrasound. There was no difference between baseline surgical and control neonates. Subcutaneous tissue increased in neonates starting POD 1 with minimal improvement by POD 3. In infants, this pattern was less pronounced with near resolution by POD 3. Intra-user variability was excellent (ICC 0.95). Inter-user variability was very good (ICC 0.82).Conclusion: Point-of-care skin ultrasound is a reproducible and reliable method to measure subcutaneous tissue in infants with and without congenital heart disease. Acute increases in subcutaneous tissue suggests development of skin edema, consistent with extravascular fluid overload. There is evidence of skin edema starting POD 1 in all subjects with no substantial improvement by POD 3 in neonates. Point-of-care ultrasound could be an objective way to measure extravascular fluid overload in infants. Further research is needed to determine how extravascular fluid overload correlates to clinical outcomes.


PEDIATRICS ◽  
1989 ◽  
Vol 83 (5) ◽  
pp. 790-791
Author(s):  
D. WOODROW BENSON ◽  
James Moller ◽  
Donald C. Fyler ◽  
David E. Fixler

In the past 20 years, considerable change has occurred in the profile of congenital heart disease regarding both diagnosis and treatment. The profile has changed from older to younger patients; the essence of this change has been from pediatric to infant to neonatal cardiology. There has been a shift from palliative to more definitive surgical procedures and a change from invasive (cardiac catheterization) to noninvasive (echocardiography) diagnostic methods. The profile has changed from definitive surgical treatment limited to simple lesions to surgical treatment of the most complex lesions. There has been steady improvement in the recognition of cases of congenital heart disease. Of all children admitted to hospitals for treatment of congenital heart disease, the portion less than three days of age has increased from 24% in 1969 to 1972 to 33% in 1982 to 1986.