scholarly journals Electrical Impedance Tomography for Cardio-Pulmonary Monitoring

2019 ◽  
Vol 8 (8) ◽  
pp. 1176 ◽  
Author(s):  
Christian Putensen ◽  
Benjamin Hentze ◽  
Stefan Muenster ◽  
Thomas Muders

Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).

2020 ◽  
pp. 204589402098404
Author(s):  
Siyi Yuan ◽  
Huaiwu He ◽  
Yun Long ◽  
Yi Chi ◽  
Inéz Frerichs ◽  
...  

Background: Several animal studies have shown that regional lung perfusion could be effectively estimated by the hypertonic saline contrast electrical impedance tomography (EIT) method. Here, we reported an application of this method to dynamically assess regional pulmonary perfusion defect in a patient with acute massive pulmonary embolism. Case presentation: A 68-year-old man experienced sudden dyspnea and cardiac arrest during out-of-bed physical activity on the first day after partial mediastinal tumor resection. Acute pulmonary embolism (PE) was suspected due to acute enlargement of right heart and fixed inferior venous cava measured with bedside ultrasound. The computed tomography pulmonary angiography further confirmed large embolism in both left and right main pulmonary arteries and branches. The regional time impedance curves, which were obtained by a bolus of 10ml 10% NaCl through the central venous catheter, were then analyzed to quantitatively assess regional perfusion. Normal ventilation distribution with massive defects in regional perfusion in both lungs was observed, leading to a ventilation-perfusion mismatch and low oxygenation index (PaO2/FiO2=86 mmHg) at the first day of PE. The anticoagulation was performed with heparin, and the patient’s condition (such as shock, dyspnea, hypoxemia etc.), regional lung perfusion defect and ventilation-perfusion mismatch continuously improved in the following days. Conclusions: This case implies that EIT might have the potential to assess and monitor regional perfusion for rapid diagnosis of fatal PE in clinical practice.


2020 ◽  
Vol 129 (5) ◽  
pp. 1140-1149
Author(s):  
Martina Mosing ◽  
Andreas D. Waldmann ◽  
Muriel Sacks ◽  
Peter Buss ◽  
Jordyn M. Boesch ◽  
...  

Electrical impedance tomography measurements of regional ventilation and perfusion applied to etorphine-immobilized white rhinoceroses in lateral recumbency revealed a pronounced disproportional shift of the measured ventilation and perfusion toward the nondependent lung. The dependent lung was minimally ventilated and perfused, but still aerated. Perfusion was found primarily around the hilum of the nondependent lung. These shifts can explain the gas exchange impairments found in this study. Breath holding can redistribute ventilation.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Huaiwu He ◽  
Yi Chi ◽  
Yun Long ◽  
Siyi Yuan ◽  
Rui Zhang ◽  
...  

Abstract Background The aim of this study was to validate whether regional ventilation and perfusion data measured by electrical impedance tomography (EIT) with saline bolus could discriminate three broad acute respiratory failure (ARF) etiologies. Methods Perfusion image was generated from EIT-based impedance–time curves caused by 10 ml 10% NaCl injection during a respiratory hold. Ventilation image was captured before the breath holding period under regular mechanical ventilation. DeadSpace%, Shunt% and VQMatch% were calculated based on lung perfusion and ventilation images. Ventilation and perfusion maps were divided into four cross-quadrants (lower left and right, upper left and right). Regional distribution defects of each quadrant were scored as 0 (distribution% ≥ 15%), 1 (15% > distribution% ≥ 10%) and 2 (distribution% < 10%). Data percentile distributions in the control group and clinical simplicity were taken into consideration when defining the scores. Overall defect scores (DefectV, DefectQ and DefectV+Q) were the sum of four cross-quadrants of the corresponding images. Results A total of 108 ICU patients were prospectively included: 93 with ARF and 15 without as a control. PaO2/FiO2 was significantly correlated with VQMatch% (r = 0.324, P = 0.001). Three broad etiologies of ARF were identified based on clinical judgment: pulmonary embolism-related disease (PED, n = 14); diffuse lung involvement disease (DLD, n = 21) and focal lung involvement disease (FLD, n = 58). The PED group had a significantly higher DeadSpace% [40(24)% vs. 14(15)%, PED group vs. the rest of the subjects; median(interquartile range); P < 0.0001] and DefectQ score than the other groups [1(1) vs. 0(1), PED vs. the rest; P < 0.0001]. The DLD group had a significantly lower DefectV+Q score than the PED and FLD groups [0(1) vs. 2.5(2) vs. 3(3), DLD vs. PED vs. FLD; P < 0.0001]. The FLD group had a significantly higher DefectV score than the other groups [2(2) vs. 0(1), FLD vs. the rest; P < 0.0001]. The area under the receiver operating characteristic (AUC) for using DeadSpace% to identify PED was 0.894 in all ARF patients. The AUC for using the DefectV+Q score to identify DLD was 0.893. The AUC for using the DefectV score to identify FLD was 0.832. Conclusions Our study showed that it was feasible to characterize three broad etiologies of ARF with EIT-based regional ventilation and perfusion. Further study is required to validate clinical applicability of this method. Trial registration clinicaltrials, NCT04081142. Registered 9 September 2019—retrospectively registered, https://clinicaltrials.gov/show/NCT04081142.


2012 ◽  
Vol 112 (1) ◽  
pp. 225-236 ◽  
Author(s):  
João Batista Borges ◽  
Fernando Suarez-Sipmann ◽  
Stephan H. Bohm ◽  
Gerardo Tusman ◽  
Alexandre Melo ◽  
...  

The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was −0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.


Respirology ◽  
2011 ◽  
Vol 16 (3) ◽  
pp. 523-531 ◽  
Author(s):  
FLORIAN REIFFERSCHEID ◽  
GUNNAR ELKE ◽  
SVEN PULLETZ ◽  
BARBARA GAWELCZYK ◽  
INGMAR LAUTENSCHLÄGER ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document