scholarly journals Near-Infrared Spectroscopy (NIRS) versus Hyperspectral Imaging (HSI) to Detect Flap Failure in Reconstructive Surgery: A Systematic Review

Life ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 65
Author(s):  
Anouk A. M. A. Lindelauf ◽  
Alexander G. Saelmans ◽  
Sander M. J. van Kuijk ◽  
René R. W. J. van der Hulst ◽  
Rutger M. Schols

Rapid identification of possible vascular compromise in free flap reconstruction to minimize time to reoperation improves achieving free flap salvage. Subjective clinical assessment, often complemented with handheld Doppler, is the golden standard for flap monitoring; but this lacks consistency and may be variable. Non-invasive optical methods such as near-infrared spectroscopy (NIRS) and hyperspectral imaging (HSI) could facilitate objective flap monitoring. A systematic review was conducted to compare NIRS with HSI in detecting vascular compromise in reconstructive flap surgery as compared to standard monitoring. A literature search was performed using PubMed and Embase scientific database in August 2021. Studies were selected by two independent reviewers. Sixteen NIRS and five HSI studies were included. In total, 3662 flap procedures were carried out in 1970 patients using NIRS. Simultaneously; 90 flaps were performed in 90 patients using HSI. HSI and NIRS flap survival were 92.5% (95% CI: 83.3–96.8) and 99.2% (95% CI: 97.8–99.7). Statistically significant differences were observed in flap survival (p = 0.02); flaps returned to OR (p = 0.04); salvage rate (p < 0.01) and partial flap loss rate (p < 0.01). However, no statistically significant difference was observed concerning flaps with vascular crisis (p = 0.39). NIRS and HSI have proven to be reliable; accurate and user-friendly monitoring methods. However, based on the currently available literature, no firm conclusions can be drawn concerning non-invasive monitoring technique superiority

2021 ◽  
pp. 088506662199709
Author(s):  
Michael D. Wood ◽  
J. Gordon Boyd ◽  
Nicole Wood ◽  
James Frank ◽  
Timothy D. Girard ◽  
...  

Background: Several studies have previously reported the presence of altered cerebral perfusion during sepsis. However, the role of non-invasive neuromonitoring, and the impact of altered cerebral perfusion, in sepsis patients with delirium remains unclear. Methods: We performed a systematic review of studies that used near-infrared spectroscopy (NIRS) and/or transcranial Doppler (TCD) to assess adults (≥18 years) with sepsis and delirium. From study inception to July 28, 2020, we searched the following databases: Ovid MedLine, Embase, Cochrane Library, and Web of Science. Results: Of 1546 articles identified, 10 met our inclusion criteria. Although NIRS-derived regional cerebral oxygenation was consistently lower, this difference was only statistically significant in one study. TCD-derived cerebral blood flow velocity was inconsistent across studies. Importantly, both impaired cerebral autoregulation during sepsis and increased cerebrovascular resistance were associated with delirium during sepsis. However, the heterogeneity in NIRS and TCD devices, duration of recording (from 10 seconds to 72 hours), and delirium assessment methods (e.g., electronic medical records, confusion assessment method for the intensive care unit), precluded meta-analysis. Conclusion: The available literature demonstrates that cerebral perfusion disturbances may be associated with delirium in sepsis. However, future investigations will require consistent definitions of delirium, delirium assessment training, harmonized NIRS and TCD assessments (e.g., consistent measurement site and length of recording), as well as the quantification of secondary and tertiary variables (i.e., Cox, Mxa, MAPOPT), in order to fully assess the relationship between cerebral perfusion and delirium in patients with sepsis.


2016 ◽  
Vol 76 (5) ◽  
pp. 590-597 ◽  
Author(s):  
Ying Chen ◽  
Zhenzhou Shen ◽  
Zhimin Shao ◽  
Peirong Yu ◽  
Jiong Wu

Microsurgery ◽  
2020 ◽  
Vol 40 (2) ◽  
pp. 268-275 ◽  
Author(s):  
Ethan Newton ◽  
Oleksandr Butskiy ◽  
Babak Shadgan ◽  
Eitan Prisman ◽  
Donald W. Anderson

2021 ◽  
Vol 13 (6) ◽  
pp. 1128
Author(s):  
Iman Tahmasbian ◽  
Natalie K Morgan ◽  
Shahla Hosseini Bai ◽  
Mark W Dunlop ◽  
Amy F Moss

Hyperspectral imaging (HSI) is an emerging rapid and non-destructive technology that has promising application within feed mills and processing plants in poultry and other intensive animal industries. HSI may be advantageous over near infrared spectroscopy (NIRS) as it scans entire samples, which enables compositional gradients and sample heterogenicity to be visualised and analysed. This study was a preliminary investigation to compare the performance of HSI with that of NIRS for quality measurements of ground samples of Australian wheat and to identify the most important spectral regions for predicting carbon (C) and nitrogen (N) concentrations. In total, 69 samples were scanned using an NIRS (400–2500 nm), and two HSI cameras operated in 400–1000 nm (VNIR) and 1000–2500 nm (SWIR) spectral regions. Partial least square regression (PLSR) models were used to correlate C and N concentrations of 63 calibration samples with their spectral reflectance, with 6 additional samples used for testing the models. The accuracy of the HSI predictions (full spectra) were similar or slightly higher than those of NIRS (NIRS Rc2 for C = 0.90 and N = 0.96 vs. HSI Rc2 for C (VNIR) = 0.97 and N (SWIR) = 0.97). The most important spectral region for C prediction identified using HSI reflectance was 400–550 nm with R2 of 0.93 and RMSE of 0.17% in the calibration set and R2 of 0.86, RMSE of 0.21% and ratio of performance to deviation (RPD) of 2.03 in the test set. The most important spectral regions for predicting N concentrations in the feed samples included 1451–1600 nm, 1901–2050 nm and 2051–2200 nm, providing prediction with R2 ranging from 0.91 to 0.93, RMSE ranging from 0.06% to 0.07% in the calibration sets, R2 from 0.96 to 0.99, RMSE of 0.06% and RPD from 3.47 to 3.92 in the test sets. The prediction accuracy of HSI and NIRS were comparable possibly due to the larger statistical population (larger number of pixels) that HSI provided, despite the fact that HSI had smaller spectral range compared with that of NIRS. In addition, HSI enabled visualising the variability of C and N in the samples. Therefore, HSI is advantageous compared to NIRS as it is a multifunctional tool that poses many potential applications in data collection and quality assurance within feed mills and poultry processing plants. The ability to more accurately measure and visualise the properties of feed ingredients has potential economic benefits and therefore additional investigation and development of HSI in this application is warranted.