hyperspectral imaging
Recently Published Documents


TOTAL DOCUMENTS

4584
(FIVE YEARS 1645)

H-INDEX

89
(FIVE YEARS 16)

2022 ◽  
Vol 151 ◽  
pp. 106889
Author(s):  
Wen Chen ◽  
Ming-Jie Sun ◽  
Wei-Jie Deng ◽  
Hai-Xiang Hu ◽  
Li-Jing Li ◽  
...  

Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 603
Author(s):  
Lukáš Krauz ◽  
Petr Páta ◽  
Jan Kaiser

Fine art photography, paper documents, and other parts of printing that aim to keep value are searching for credible techniques and mediums suitable for long-term archiving purposes. In general, long-lasting pigment-based inks are used for archival print creation. However, they are very often replaced or forged by dye-based inks, with lower fade resistance and, therefore, lower archiving potential. Frequently, the difference between the dye- and pigment-based prints is hard to uncover. Finding a simple tool for countrified identification is, therefore, necessary. This paper assesses the spectral characteristics of dye- and pigment-based ink prints using visible near-infrared (VNIR) hyperspectral imaging. The main aim is to show the spectral differences between these ink prints using a hyperspectral camera and subsequent hyperspectral image processing. Two diverse printers were exploited for comparison, a hobby dye-based EPSON L1800 and a professional pigment-based EPSON SC-P9500. The identical prints created via these printers on three different types of photo paper were recaptured by the hyperspectral camera. The acquired pixel values were studied in terms of spectral characteristics and principal component analysis (PCA). In addition, the obtained spectral differences were quantified by the selected spectral metrics. The possible usage for print forgery detection via VNIR hyperspectral imaging is discussed in the results.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 184
Author(s):  
Tim Pruimboom ◽  
Anouk A. M. A. Lindelauf ◽  
Eric Felli ◽  
John H. Sawor ◽  
An E. K. Deliaert ◽  
...  

Mastectomy skin flap necrosis (MSFN) and partial DIEP (deep inferior epigastric artery perforator) flap loss represent two frequently reported complications in immediate autologous breast reconstruction. These complications could be prevented when areas of insufficient tissue perfusion are detected intraoperatively. Hyperspectral imaging (HSI) is a relatively novel, non-invasive imaging technique, which could be used to objectively assess tissue perfusion through analysis of tissue oxygenation patterns (StO2%), near-infrared (NIR%), tissue hemoglobin (THI%), and tissue water (TWI%) perfusion indices. This prospective clinical pilot study aimed to evaluate the efficacy of HSI for tissue perfusion assessment and to identify a cut-off value for flap necrosis. Ten patients with a mean age of 55.4 years underwent immediate unilateral autologous breast reconstruction. Prior, during and up to 72 h after surgery, a total of 19 hyperspectral images per patient were acquired. MSFN was observed in 3 out of 10 patients. No DIEP flap necrosis was observed. In all MSFN cases, an increased THI% and decreased StO2%, NIR%, and TWI% were observed when compared to the vital group. StO2% was found to be the most sensitive parameter to detect MSFN with a statistically significant lower mean StO2% (51% in the vital group versus 32% in the necrosis group, p < 0.0001) and a cut-off value of 36.29% for flap necrosis. HSI has the potential to accurately assess mastectomy skin flap perfusion and discriminate between vital and necrotic skin flap during the early postoperative period prior to clinical observation. Although the results should be confirmed in future studies, including DIEP flap necrosis specifically, these findings suggest that HSI can aid clinicians in postoperative mastectomy skin flap and DIEP flap monitoring.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Max Kistler ◽  
Hannes Köhler ◽  
Jan Theopold ◽  
Ines Gockel ◽  
Andreas Roth ◽  
...  

AbstractTo investigate, whether hyperspectral imaging (HSI) is able to reliably differentiate between healthy and damaged cartilage tissue. A prospective diagnostic study was performed including 21 patients undergoing open knee surgery. HSI data were acquired during surgery, and the joint surface’s cartilage was assessed according to the ICRS cartilage injury score. The HSI system records light spectra from 500 to 1000 nm and generates several parameters including tissue water index (TWI) and the absorbance at 960 nm and 540 nm. Receiver operating characteristic curves were calculated to assess test parameters for threshold values of HSI. Areas with a cartilage defect ICRS grade ≥ 3 showed a significantly lower TWI (p = 0.026) and higher values for 540 nm (p < 0.001). No difference was seen for 960 nm (p = 0.244). For a threshold of 540 nm > 0.74, a cartilage defect ICRS grade ≥ 3 could be detected with a sensitivity of 0.81 and a specificity of 0.81. TWI was not suitable for cartilage defect detection. HSI can provide reliable parameters to differentiate healthy and damaged cartilage. Our data clearly suggest that the difference in absorbance at 540 nm would be the best parameter to achieve accurate identification of damaged cartilage.


2022 ◽  
Vol 14 (2) ◽  
pp. 319
Author(s):  
Tanzeel U. Rehman ◽  
Libo Zhang ◽  
Dongdong Ma ◽  
Jian Jin

Hyperspectral imaging has increasingly been used in high-throughput plant phenotyping systems. Rapid advancement in the field of phenotyping has resulted in a wide array of hyperspectral imaging systems. However, sharing the plant feature prediction models between different phenotyping facilities becomes challenging due to the differences in imaging environments and imaging sensors. Calibration transfer between imaging facilities is crucially important to cope with such changes. Spectral space adjustment methods including direct standardization (DS), its variants (PDS, DPDS) and spectral scale transformation (SST) require the standard samples to be imaged in different facilities. However, in real-world scenarios, imaging the standard samples is practically unattractive. Therefore, in this study, we presented three methods (TCA, c-PCA, and di-PLSR) to transfer the calibration models without requiring the standard samples. In order to compare the performance of proposed approaches, maize plants were imaged in two greenhouse-based HTPP systems using two pushbroom-style hyperspectral cameras covering the visible near-infrared range. We tested the proposed methods to transfer nitrogen content (N) and relative water content (RWC) calibration models. The results showed that prediction R2 increased by up to 14.50% and 42.20%, while the reduction in RMSEv was up to 74.49% and 76.72% for RWC and N, respectively. The di-PLSR achieved the best results for almost all the datasets included in this study, with TCA being second. The performance of c-PCA was not at par with the di-PLSR and TCA. Our results showed that the di-PLSR helped to recover the performance of RWC, and N models plummeted due to the differences originating from new imaging systems (sensor type, spectrograph, lens system, spatial resolution, spectral resolution, field of view, bit-depth, frame rate, and exposure time) or lighting conditions. The proposed approaches can alleviate the requirement of developing a new calibration model for a new phenotyping facility or to resort to the spectral space adjustment using the standard samples.


2022 ◽  
Vol 16 (1) ◽  
pp. 43-59
Author(s):  
Christopher Donahue ◽  
S. McKenzie Skiles ◽  
Kevin Hammonds

Abstract. It is well understood that the distribution and quantity of liquid water in snow is relevant for snow hydrology and avalanche forecasting, yet detecting and quantifying liquid water in snow remains a challenge from the micro- to the macro-scale. Using near-infrared (NIR) spectral reflectance measurements, previous case studies have demonstrated the capability to retrieve surface liquid water content (LWC) of wet snow by leveraging shifts in the complex refractive index between ice and water. However, different models to represent mixed-phase optical properties have been proposed, including (1) internally mixed ice and water spheres, (2) internally mixed water-coated ice spheres, and (3) externally mixed interstitial ice and water spheres. Here, from within a controlled laboratory environment, we determined the optimal mixed-phase optical property model for simulating wet snow reflectance using a combination of NIR hyperspectral imaging, radiative transfer simulations (Discrete Ordinate Radiative Transfer model, DISORT), and an independent dielectric LWC measurement (SLF Snow Sensor). Maps of LWC were produced by finding the lowest residual between measured reflectance and simulated reflectance in spectral libraries, generated for each model with varying LWC and grain size, and assessed against the in situ LWC sensor. Our results show that the externally mixed model performed the best, retrieving LWC with an uncertainty of ∼1 %, while the simultaneously retrieved grain size better represented wet snow relative to the established scaled band area method. Furthermore, the LWC retrieval method was demonstrated in the field by imaging a snowpit sidewall during melt conditions and mapping LWC distribution in unprecedented detail, allowing for visualization of pooling water and flow features.


2022 ◽  
Author(s):  
Yusuke Saita ◽  
Daiki Shimoyama ◽  
Ryohei Takahashi ◽  
Takanori Nomura

Sign in / Sign up

Export Citation Format

Share Document