Computer-aided design and computer-aided manufacturing (CAD–CAM) enable subtractive or additive fabrication of temporary fixed dental prostheses (FDPs). The present in-vitro study aimed to compare the fracture resistance of both milled and additive manufactured three-unit FDPs and bar-shaped, ISO-conform specimens. Polymethylmethacrylate was used for subtractive manufacturing and a light-curing resin for additive manufacturing. Three (bars) and four (FDPs) different printing orientations were evaluated. All bars (n = 32) were subjected to a three-point bending test after 24 h of water storage. Half of the 80 FDPs were dynamically loaded (250,000 cycles, 98 N) with simultaneous hydrothermal cycling. Non-aged (n = 40) and surviving FDPs (n = 11) were subjected to static loading until fracture. Regarding the bar-shaped specimens, the milled group showed the highest flexural strength (114 ± 10 MPa, p = 0.001), followed by the vertically printed group (97 ± 10 MPa, p < 0.007). Subtractive manufactured FDPs revealed the highest fracture strength (1060 ± 89 N) with all specimens surviving dynamic loading. During artificial aging, 29 of 32 printed specimens failed. The present findings indicate that both printing orientation and aging affect the strength of additive manufactured specimens. The used resin and settings cannot be recommended for additive manufacturing of long-term temporary three-unit FDPs.

Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1401
Author(s):  
Doo-Bin Song ◽  
Man-So Han ◽  
Si-Chul Kim ◽  
Junyong Ahn ◽  
Yong-Woon Im ◽  
...  

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.


2019 ◽  
Vol 18 (4) ◽  
pp. 764-772
Author(s):  
Asa Yazdani Fard ◽  
Zuryati Ab Ghani ◽  
Zaihan Ariffin ◽  
Dasmawati Mohamad

Background: Studies on microleakage of Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) crowns are abundant. However many of them are inconclusive, especially those using self adhesive cements. Aims: To compare the microleakage between CAD/CAM crowns milled out of feldspathic ceramic and resin nano ceramics, cemented with three resin cements. Materials and Methods: Crown preparation was made on 54 extracted human premolars. Impressions were captured optically using CEREC 3D machine intraoral camera, and crowns were milled from feldspathic ceramic (CEREC® Blocs PC, VITA) and resin nano ceramic (Lava™ Ultimate CAD/CAM Restorative, 3M ESPE) blocks. The crowns were then cemented with three cements (n = 9); RelyX™ U200 Self-Adhesive Resin Cement (3M ESPE); NX3 Nexus ® cement with two-step etch-and-rinse adhesive (Kerr Corporation) or three/multistep etch-and-rinse resin cement, Variolink® II/Syntac Classic (Ivoclar Vivadent). The specimens were kept in water for 24 hours, thermocycled, and then soaked in methylene blue dye for 24 hours, before being sectioned mesiodistally. Microleakage was assessed using a fivepoint scale using stereomicroscope. Statistical analysis of the data was carried out using ONEWay ANOVA. Results: CEREC® Blocs PC crowns showed significantly less microleakage (p< 0.001) compared to Lava™ Ultimate. RelyX™ U200 showed significantly lower microleakage (p< 0.001) compared to other cements. Combination of Lava™ Ultimate crown cemented with RelyX™ U200 showed the least microleakage (p< 0.001). Conclusions: The microleakage scores were affected by the types of crown and cements. Bangladesh Journal of Medical Science Vol.18(4) 2019 p.764-772


2020 ◽  
Vol 10 (21) ◽  
pp. 7735
Author(s):  
Hai Yen Mai ◽  
Jae-Min Seo ◽  
Jae-Kwang Jung ◽  
Du-Hyeong Lee

Occlusal contact loss occasionally occurs following the placement of implant-supported fixed dental prostheses in the posterior region. This complication is caused by the change in the vertical dimension of occlusion after the recovery of mastication. The change is probably related to the prosthesis sinking phenomenon and previous mandibular dislocation. The use of interim prostheses could help re-establish the vertical dimension of occlusion. The definitive prostheses can then be accurately fabricated using digital techniques in the newly established vertical dimension. In this case report, we introduce a protocol incorporating a computer-aided design and computer-aided manufacturing (CAD-CAM) interim prosthesis and digital techniques to minimize the occurrence of unexpected initial occlusal changes in the prosthetic treatment of implant-supported prostheses in the posterior region.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5588
Author(s):  
Angelika Rauch ◽  
Sebastian Hahnel ◽  
Elena Günther ◽  
Wolfgang Bidmon ◽  
Oliver Schierz

The aim of this study was to compare the clinical properties of tooth-colored computer-aided design/computer-aided manufacturing (CAD/CAM) materials for the fabrication of a 3-unit fixed dental prostheses (FDPs) in the same clinical scenario. A 53-year-old female patient was supplied with a 3-unit FDP to replace a second premolar in the upper jaw. Restorations were fabricated from 3 mol%, 4 mol%, and 5 mol% yttrium oxide zirconia, zirconia with translucency gradient, indirect composite resin, polyetheretherketone (PEEK), and polyetherketoneketone (PEKK). Milling time, weight, and radiopacity were investigated. Esthetics were examined following the US Public Health Service criteria (USPHS). The milling time for zirconia was twice as high as for the indirect composite resin, PEEK, or PEKK. The latter materials had a weight of 2 g each, while zirconia restorations yielded 5 g. Zirconia presented intense radiopacity. PEEK and PEKK required veneering and an opaquer was applied to the PEKK framework. All FDPs showed acceptable esthetics. PEEK and PEKK restorations were featured by a grayish shimmering. A variety of CAD/CAM materials are available to fabricate 3-unit FDPs with esthetically acceptable results. In the esthetic zone, PEEK and PEKK require veneering and an opaquer might be applied. Milling time, weight, and radiopacity were relatively high for zirconia FDPs.