Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: An in vitro study

2020 ◽  
Vol 64 (2) ◽  
pp. 152-158 ◽  
Author(s):  
Seen-Young Kang ◽  
Jung-Hyun Park ◽  
Ji-Hwan Kim ◽  
Woong-Chul Kim
2020 ◽  
pp. 232020682097597
Author(s):  
Ece Irem Oguz ◽  
Mehmet Ali Kılıçarslan ◽  
Merve Erdog˘ Özgür ◽  
Kaan Orhan ◽  
Sohaib Shujaat

Aim: To compare the marginal adaptation of crowns fabricated by using three different resin-ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: Crowns fabricated from three different resin-ceramic CAD/CAM blocks, applied on a typodont premolar (#14), were tested with regard to marginal adaptation, in this in vitro study. The typodont maxillary first premolar was prepared to serve as the master die and digitized with an intraoral scanner. The same virtual crown design was used to fabricate all specimens. Forty-eight crowns were fabricated from the same virtual crown design using three different CAD/CAM resin-ceramic blocks as follows ( n = 16): Lava Ultimate (LU), GC Cerasmart (GC), Vita Enamic (VE). Master die and crowns were scanned with a laboratory scanner and three-dimensional data were transferred into three-matic software. The software calculated the mean of the marginal discrepancy (MD) for each crown in negative and positive values, representing under and over estimation of the crown margin, respectively. A marginal discrepancy index (MDI) was obtained for each group using negative and positive MDs. All data were statistically analyzed using one-way analysis of variance and Tukey’s honest significance test ( α = 0.05). Results: The analysis of variance showed no statistical differences between materials regarding the negative and positive MDs ( P > .05). The MDI for LU was lower than GC and VE ( P < .05). Conclusion: The marginal adaptation of different resin-ceramic materials was different with regard to MDI values. Nevertheless, the MD values of all groups were within the clinically acceptable range.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


Sign in / Sign up

Export Citation Format

Share Document