scholarly journals Validation of Lithuanian Arthroplasty Register Telephone Survey of 2769 Patients Operated for Total Knee Replacement

Medicina ◽  
2019 ◽  
Vol 55 (6) ◽  
pp. 310
Author(s):  
Egle Terteliene ◽  
Kazimieras Grigaitis ◽  
Otto Robertsson ◽  
Narunas Porvaneckas ◽  
Jolanta Dadoniene ◽  
...  

Background and objectives: The aim of our study is to validate the registration of knee arthroplasty revisions in the Lithuanian Arthroplasty Register (LAR) and thus give an indication of the accuracy of the published revision rates. Materials and methods: A total of 4269 primary total knee arthroplasties (TKAs) registered in the LAR between 2013 and 2015 were included. Two years after surgery the patients were contacted by phone in order to inquire if they had been subject to revision. The information from the patients was then cross checked against what had been registered in the LAR, and in case of a revision not having been registered hospital charts were investigated. Thus, the patients were followed up with regarding revision and/or death until 2017. A true revision was defined as an addition, exchange, or removal of one or all components. Results: Out of 4269 primary TKAs, we managed to contact and interview 2769 patients. Nine small hospitals were not able to provide contact details (telephone numbers) for 533 patients (549 knees). Sixty-seven patients (67 knees) were deceased (data from the Lithuanian National Census Register) and a further 438 patients (565 knees) appeared to have a wrong or non-valid telephone number, leaving 3031 (3091 knees) patients being contacted. Of those, 262 patients (266 knees) refused to participate in the study which left 2769 responders (2825 knees). Sixty-one patients said that reoperation had been performed on the index knee within two years of their primary surgery. After checking with the clinics, 10 were surgical procedures on the knee but not true revisions by our criteria. Out of the 51 true revisions we found that 46 were registered to the LAR as revised, while five (9.8%) revisions were missing. Conclusions: We conclude that the Lithuanian Arthroplasty Register has a good completeness of registered revision TKAs as only 9.8% of revisions were missing.

2021 ◽  
Vol 2 (11) ◽  
pp. 921-925
Author(s):  
Afton K. Limberg ◽  
Cody C. Wyles ◽  
Michael J. Taunton ◽  
Arlen D. Hanssen ◽  
Mark W. Pagnano ◽  
...  

Aims Varus-valgus constrained (VVC) devices are typically used in revision settings, often with stems to mitigate the risk of aseptic loosening. However, in at least one system, the VVC insert is compatible with the primary posterior-stabilized (PS) femoral component, which may be an option in complex primary situations. We sought to determine the implant survivorship, radiological and clinical outcomes, and complications when this VVC insert was coupled with a PS femur without stems in complex primary total knee arthroplasties (TKAs). Methods Through our institution’s total joint registry, we identified 113 primary TKAs (103 patients) performed between 2007 and 2017 in which a VVC insert was coupled with a standard cemented PS femur without stems. Mean age was 68 years (SD 10), mean BMI was 32 kg/m2 (SD 7), and 59 patients (50%) were male. Mean follow-up was four years (2 to 10). Results The five-year survivorship free from aseptic loosening was 100%. The five-year survivorship free from any revision was 99%, with the only revision performed for infection. The five-year survivorship free from reoperation was 93%. The most common reoperation was treatment for infection (n = 4; 4%), followed by manipulation under anaesthesia (MUA; n = 2; 2%). Survivorship free from any complication at five years was 90%, with superficial wound infection as the most frequent (n = 4; 4%). At most recent follow-up, two TKAs had non-progressive radiolucent lines about both the tibial and femoral components. Knee Society Scores improved from 53 preoperatively to 88 at latest follow-up (p < 0.001). Conclusion For complex primary TKA in occasional situations, coupling a VVC insert with a standard PS femur without stems proved reliable and durable at five years. Longer-term follow-up is required before recommending this technique more broadly. Cite this article: Bone Jt Open 2021;2(11):921–925.


The Knee ◽  
2005 ◽  
Vol 12 (5) ◽  
pp. 336-340 ◽  
Author(s):  
Huseyin S. Yercan ◽  
Tarik Ait Si Selmi ◽  
Tahir S. Sugun ◽  
Philippe Neyret

2010 ◽  
Vol 92-B (9) ◽  
pp. 1259-1261 ◽  
Author(s):  
S. Gupta ◽  
A. Augustine ◽  
L. Horey ◽  
R. M. D. Meek ◽  
M. G. Hullin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document