scholarly journals Design and Test of a Soft Plantar Force Measurement System for Gait Detection

Sensors ◽  
2012 ◽  
Vol 12 (12) ◽  
pp. 16628-16640 ◽  
Author(s):  
Xuefeng Zhang ◽  
Yulong Zhao ◽  
Zhengyong Duan ◽  
Yan Liu
Sensor Review ◽  
2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Xiang Li ◽  
Keyi Wang ◽  
Yan Lin Wang ◽  
Kui Cheng Wang

Purpose Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture plays a critical role for rehabilitation, footwear design, clinical diagnostics and sports activities, and so on. This paper aims to review plantar force measurement technologies based on piezoelectric materials, which can make the reader understand preliminary works systematically and provide convenience for researchers to further study. Design/methodology/approach The review introduces working principle of piezoelectric sensor, structures and hardware design of plantar force measurement systems based on piezoelectric materials. The structures of sensors in plantar force measurement systems can be divided into four kinds, including monolayered sensor, multilayered sensor, tri-axial sensor and other sensor. The previous studies about plantar force measurement system based on piezoelectric technology are reviewed in detail, and their characteristics and performances are compared. Findings A good deal of measurement technologies have been studied by researchers to detect and analyze the plantar force. Among these measurement technologies, taking advantage of easy fabrication and high sensitivity, piezoelectric sensor is an ideal candidate sensing element. However, the number and arrangement of the sensors will influence the characteristics and performances of plantar force measurement systems. Therefore, it is necessary to further study plantar force measurement system for better performances. Originality/value So far, many plantar force measurement systems have been proposed, and several reviews already introduced plantar force measurement systems in the aspect of types of pressure sensors, experimental setups for foot pressure measurement analysis and the technologies used in plantar shear stress measurements. However, this paper reviews plantar force measurement systems based on piezoelectric materials. The structures of piezoelectric sensors in the measurement systems are discussed. Hardware design applied to measurement system is summarized. Moreover, the main point of further study is presented in this paper.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Andrea Cristina de Lima-Pardini ◽  
Raymundo Machado de Azevedo Neto ◽  
Daniel Boari Coelho ◽  
Catarina Costa Boffino ◽  
Sukhwinder S. Shergill ◽  
...  

2011 ◽  
Vol 383-390 ◽  
pp. 774-779
Author(s):  
Ye Min Guo ◽  
Lan Mei Wang ◽  
Rui Yong Xue

According to the requirements of measurement of plantar pressure and shear stress in the meantime, this thesis puts forward a plan to construct a new insole plantar pressure and shear stress system based on multifunction data acquisition modular and Lab VIEW. Then the hardware part and software part are designed and developed respectively. There are 3 sensors are arrayed at each measurement point, that means 3 sensors are assembled in 3 different directions of X,Y and Z . The piezoelectric ceramic type sensors are designed, manufactured and calibrated according to scientific methods. Meanwhile, the DAQ card is selected carefully. Of course, the software part is developed based on Lab VIEW. A series of tests are performed in order to validate the function of the measurement system. The results satisfy the anticipated design requirements. At last, the problems and application trend of the measurement system are predicted.


2009 ◽  
Vol 37 (1) ◽  
pp. 54-62 ◽  
Author(s):  
O. FROMENTIN ◽  
C. LASSAUZAY ◽  
S. ABI NADER ◽  
J. FEINE ◽  
R. F. De ALBUQUERQUE JUNIOR

2002 ◽  
Vol 26 (8) ◽  
pp. 1608-1614
Author(s):  
Gyeong-Pyo Ha ◽  
Jung-Su Kim ◽  
Myeong-Rae Jo ◽  
Dae-Yun O

2007 ◽  
Vol 546-549 ◽  
pp. 2103-2106 ◽  
Author(s):  
X.L. Wu ◽  
W.M. Yang ◽  
S.H. Zhu ◽  
J.Z. Guo ◽  
T.N. Lu ◽  
...  

The effect of magnet moving speed on the relaxation of the maximum levitation force of YBCO bulk has been investigated. The experiment was carried out between a cylinder permanent magnet and a single-domain YBCO bulk, and the levitation force was measured using a self-made levitation force measurement system. It is found that the levitation force decreases with time after the gap distance between the magnet and YBCO bulk reduced to 2 mm and kept for the test. It is also found that the levitation force and its relaxation rate is different for different moving speed between the magnet and the YBCO bulk, and the higher the moving speed, the greater the relaxation rate of levitation force. However, the largest levitation force is obtained at an optimal speed, the higher the levitation force, and the faster the relaxation of levitation force.


Sign in / Sign up

Export Citation Format

Share Document