scholarly journals Feasibility and Reliability Assessment of Video-Based Motion Analysis and Surface Electromyography in Children with Fragile X during Gait

Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4746
Author(s):  
Zimi Sawacha ◽  
Fabiola Spolaor ◽  
Weronika Joanna Piątkowska ◽  
Federica Cibin ◽  
Alfredo Ciniglio ◽  
...  

Fragile X Syndrome (FXS), the leading form of inherited intellectual disability and autism, is characterized by specific musculoskeletal conditions. We hypothesized that gait analysis in FXS could be relevant for the evaluation of motor control of gait, and help the understanding of a possible correlation between functional and intellectual abilities. Typical deficits in executive control and hyperactivity have hampered the use of standard gait analysis. The aim of our study was to quantitatively assess musculoskeletal alterations in FXS children in standard ambulatory conditions, in a friendly environment. Ten FXS children and sixteen controls, with typical neurodevelopment, were evaluated through four synchronized video cameras and surface electromyography; lower limb joints rotations, spatiotemporal parameters, duration of muscle contraction, activation timing and envelope peaks were determined. Reliability and repeatability of the video based kinematics analysis was assessed with respect to stereophotogrammetry. The Kruskal–Wallis Test (p < 0.05) or SPM1D were used to compare different groups of subjects. Results show a consistently altered gait pattern associated with abnormal muscle activity in FXS subjects: reduced knee and excessive hip and ankle flexion, and altered duration and activity onset on all the recorded muscles (Rectus/Biceps Femoris, Tibialis Anterior, Gastrocnemius Lateralis). Results of this study could help with planning personalized rehabilitations.

Author(s):  
Gunjan Patel ◽  
Rajani Mullerpatan ◽  
Bela Agarwal ◽  
Triveni Shetty ◽  
Rajdeep Ojha ◽  
...  

Wearable inertial sensor-based motion analysis systems are promising alternatives to standard camera-based motion capture systems for the measurement of gait parameters and joint kinematics. These wearable sensors, unlike camera-based gold standard systems, find usefulness in outdoor natural environment along with confined indoor laboratory-based environment due to miniature size and wireless data transmission. This study reports validation of our developed (i-Sens) wearable motion analysis system against standard motion capture system. Gait analysis was performed at self-selected speed on non-disabled volunteers in indoor ( n = 15) and outdoor ( n = 8) environments. Two i-Sens units were placed at the level of knee and hip along with passive markers (for indoor study only) for simultaneous 3D motion capture using a motion capture system. Mean absolute percentage error (MAPE) was computed for spatiotemporal parameters from the i-Sens system versus the motion capture system as a true reference. Mean and standard deviation of kinematic data for a gait cycle were plotted for both systems against normative data. Joint kinematics data were analyzed to compute the root mean squared error (RMSE) and Pearson’s correlation coefficient. Kinematic plots indicate a high degree of accuracy of the i-Sens system with the reference system. Excellent positive correlation was observed between the two systems in terms of hip and knee joint angles (Indoor: hip 3.98° ± 1.03°, knee 6.48° ± 1.91°, Outdoor: hip 3.94° ± 0.78°, knee 5.82° ± 0.99°) with low RMSE. Reliability characteristics (defined using standard statistical thresholds of MAPE) of stride length, cadence, walking speed in both outdoor and indoor environment were well within the “Good” category. The i-Sens system has emerged as a potentially cost-effective, valid, accurate, and reliable alternative to expensive, standard motion capture systems for gait analysis. Further clinical trials using the i-Sens system are warranted on participants across different age groups.


2013 ◽  
Vol 10 (1) ◽  
pp. 525-545 ◽  
Author(s):  
Nenad Filipovic ◽  
Velibor Isailovic ◽  
Dalibor Nikolic ◽  
Aleksandar Peulic ◽  
Nikola Mijailovic ◽  
...  

In this study we modeled a patient specific 3D knee after anterior cruicate ligament (ACL) reconstruction. The purpose of the ACL reconstruction is to achieve stability in the entire range of motion of the knee and the establishment of the normal gait pattern. We present a new reconstruction technique that generates patient-specific 3D knee models from patient?s magnetic resonant images (MRIs). The motion of the ACL reconstruction patients is measured by OptiTrack system with six infrared cameras. Finite element model of bones, cartilage and meniscus is used for determination stress and strain distribution at different body postures during gait analysis. It was observed that the maximum effective von Mises stress distribution up to 8 MPa occurred during 30% of the gait cycle on the meniscus. The biomechanical model of the knee joint during gait analysis can provide insight into the underlying mechanisms of knee function after ACL reconstruction.


2012 ◽  
Vol 314 (1-2) ◽  
pp. 83-87 ◽  
Author(s):  
Manuela Galli ◽  
Veronica Cimolin ◽  
Veronica Crugnola ◽  
Lorenzo Priano ◽  
Francesco Menegoni ◽  
...  

2011 ◽  
Vol 41 (1) ◽  
pp. 54-62 ◽  
Author(s):  
Barbara Bockstahler ◽  
Cordula Kräutler ◽  
Peter Holler ◽  
Alexander Kotschwar ◽  
Angela Vobornik ◽  
...  