scholarly journals Groundwater-Related Issues of Ground Source Heat Pump (GSHP) Systems: Assessment, Good Practices and Proposals from the European Experience

Water ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 1573 ◽  
Author(s):  
Casasso ◽  
Sethi

Ground source heat pumps (GSHPs) gained increasing interest owing to benefits such as low heating and cooling costs, reduction of greenhouse gas emissions, and no pollutant emissions on site. However, GSHPs may have various possible interactions with underground and groundwater, which, despite the extremely rare occurrence of relevant damages, has raised concerns on their sustainability. Possible criticalities for their installation are (hydro)geological features (artesian aquifers, swelling or soluble layers, landslide-prone areas), human activities (mines, quarries, landfills, contaminated sites), and groundwater quality. Thermal alterations due to the operation of GSHPs may have an impact on groundwater chemistry and on the efficiency of neighboring installations. So far, scientific studies excluded appraisable geochemical alterations within typical ranges of GSHPs (±6 K on the initial groundwater temperature); such alterations, however, may occur for aquifer thermal energy storage over 40 °C. Thermal interferences among neighboring installations may be severe in urban areas with a high plant density, thus highlighting the need for their proper management. These issues are presented here and framed from a groundwater quality protection perspective, providing the basis for a discussion on critical aspects to be tackled in the planning, authorization, installation, and operation phase. GSHPs turn out to be safe and sustainable if care is taken in such phases, and the best available techniques are adopted.

2017 ◽  
Vol 170 (3) ◽  
pp. 103-115 ◽  
Author(s):  
Alexis Ali ◽  
Mostafa Mohamed ◽  
Mohamad Abdel-Aal ◽  
Alma Schellart ◽  
Simon Tait

2020 ◽  
Author(s):  
Eric Wagner ◽  
Benjamin McDaniel ◽  
Dragoljub Kosanovic

Ground-source heat pump (GSHP) systems have been implemented at large scales on several university campuses to provide heating and cooling. In this study, we test the idea that a GSHP system, as a replacement for an existing Combined Heat and Power (CHP) heating system coupled with conventional cooling systems, could reduce CO2 emissions, and provide a cost benefit to a university campus. We use the existing recorded annual heating and cooling loads supplied by the current system and an established technique of modeling the heat pumps and borehole heat exchangers (BHEs) using a TRNSYS model. The GSHP system is modeled to follow the parameters of industry standards and sized to provide an optimal balance of capital and operating costs. Results show that despite a decrease in heating and cooling energy usage and CO2 emissions are achieved, a significant increase in electric demand and purchased electricity result in an overall cost increase. These results highlight the need for thermal energy storage, onsite distributed energy resources and/or demand response in cases where electric heat pumps are used to help mitigate electric demand during peak periods.


2009 ◽  
Vol 41 (6) ◽  
pp. 587-595 ◽  
Author(s):  
D.P. Jenkins ◽  
R. Tucker ◽  
R. Rawlings

Sign in / Sign up

Export Citation Format

Share Document