scholarly journals Analysis of Weibull and Poisson Distribution use in Medium Voltage Circuit Breakers RUL Assessment

Author(s):  
Dragan Stevanovic

In this paper, Weibull and Poisson distribution calculation are carried out with new data to conclude a conclusion are they suitable for circuit breakers remaining useful life assessment (RUL). Old data are covering a 10 years period consisting of measured voltage drop on CB contacts and number of tripped short circuit faults. In this paper, new data, from the last 3 years, would be used to make a comparison with old data and make conclusions have been probability distributions correctly chosen.

Tehnika ◽  
2019 ◽  
Vol 74 (5) ◽  
pp. 687-693
Author(s):  
Dragan Stevanović ◽  
Aleksandar Janjić ◽  
Dragan Tasić

Author(s):  
Raymond K. Yee

A steam drum in a typical power plant has experienced in-service cracking. Nondestructive examinations (NDE) were performed and a small sample was collected from the drum to evaluate the extent of the cracking that had occurred in the drum shell. Fitness-for-service and remaining useful life analyses of the drum were performed based on the NDE results and operating conditions. In this paper, the fitness-for-service analyses of the steam drum are described. The analysis procedure, material property determination, stress analysis, limiting flaw size evaluation, and remaining useful life evaluation for the drum are discussed. Recommendations for appropriate action are also presented.


Author(s):  
Hicham Chaoui ◽  
Mohsen Kandidayeni ◽  
Loic Boulon ◽  
Sousso Kelouwani ◽  
Hamid Gualous

Sign in / Sign up

Export Citation Format

Share Document