scholarly journals Subsoil Engineering Characterization and Foundation Design in Derived Geological Coastal Sands of Ilaje Area of Ondo State, Nigeria

Engineering subsoil evaluation and foundation design have been undertaken at Ilaje area of Ondo State, Nigeria. The aim of this study was to examine the geo-electrical and geotechnical parameters of the subsoil to sustain building structures and also provide appropriate foundation design alternatives. A total of six VES stations were occupied and complemented with geotechnical analysis of seven soil samples collected at two cone penetration test locations. The result showed that all the determined geotechnical parameters of the subsoil fall within the specification recommended for foundation material by federal ministry of works and housing of Nigeria. The VES showed a predominant (66.67%) HKQ curve type. The upper 5 m is characterized by moderate thickness and high resistivity (average of 450ohm-m) values to sustain structural load. An average allowable bearing capacity of 150 KN/m2 was recommended for design of bases/footings for shallow foundation at a depth not less than 1.0 m. The obtained settlement values are less than 50 mm and within tolerable limit, for foundation width ranging from 0.5 to 3.0 m. However there was drastic reduction in settlement values (below 25mm) when the foundation width was increased to 2 and 3m. The allowable capacity of the driven pile ranges from 64 – 115 KN, 206 – 347 KN, and 418 – 677 KN at 5m, 10 m and 15 m respectively. The allowable bearing capacity for bored piles ranges from 34 – 69 KN, 85 – 165 KN, and 146 – 268 at depth levels of 5 m, 10 m, and 15 m respectively.

Author(s):  
Olumuyiwa O. Falowo ◽  
Michael B. Amodu

Integrated geophysical and geotechnical investigations for foundation design have proved to be good veritable tools in effective foundation design and construction. Geophysical and geotechnical methods involving electrical resistivity and cone penetration test have been carried out to investigate the foundation soil conditions of Ode Irele, southwestern Nigeria. Six vertical electrical sounding (VES) were carried out along two traverses; which is complemented by two cone penetration tests with seven trial tests at different subsurface depths. The geotechnical results showed that the soils are sand and silt dominated. All the tested parameters fall within the Nigeria federal ministry of works and housing specification with liquid limit (< 50%), plastic limit (< 30%), plasticity index (< 20%). The geoelectric sections identified maximum of six geoelectric/geologic subsurface layers comprising the topsoil (red sand), weathered layer (made up of coastal sand/white sand), clayey sand (which is the major aquitard in the area), intermediate sand aquifer unit. However the coastal sand layer has moderately high resistivity at shallow depth to sustain foundation load with thickness greater than 2 m. The groundwater level measured from existing borehole records 17.5 m which may not or seriously affect the bases of the foundation footing. Consequently an average allowable bearing capacity of 150 KN/m2 (ultimate bearing capacity of 450 KN/m2) would be appropriate for design of shallow foundation in the area, at a depth not less than 1.6 m in Ode Irele and 0.8 m at Ajagba. The foundation width of 0.6 m would produce minimum bearing settlement less than 25 mm. The appropriate (recommended) ultimate bearing and allowable bearing capacity for strip and square footings at depth levels of 0.6 – 1.2 m vary from 1486 – 1842 KN/m2 and 495 - 614 KN/m2; and 2056 – 2489 KN/m2 and 685 - 830 KN/m2 respectively.


2020 ◽  
Vol 67 (1) ◽  
pp. 21-33
Author(s):  
O. Falowo Olumuyiwa

AbstractThe study integrates geophysical and geotechnical methods for subsoil evaluation and shallow foundation design. The study involved six vertical electrical sounding and geotechnical investigation involving cone penetration test and laboratory soil analysis. Three major geologic units were delineated; the topsoil, weathered layer and partly weathered/fractured/fresh bedrock. The overburden thickness is in between 15.2–32.9 m. Based on resistivity (16–890 ohm-m) and thickness (12.7–32 m) the weathered layer is competent to distribute structural load to underlying soil/rock. The groundwater level varies from 4.5 to 12.3 m. Therefore an average allowable bearing capacity of 200 kPa is recommended and would be appropriate for design of shallow foundation in the area, at a depth not less than 1.0 m with an expected settlement ranging from 9.03–48.20 mm. The ultimate bearing and allowable bearing capacity for depth levels of 1–3 m vary from 1403–2666 kPa and 468–889 kPa for strip footing while square footing varies in between 1956–3489 kPa and 652–1163 kPa respectively.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
FALOWO OLUSOLA OLUMUYIWA

Geotechnical and geo-electrical investigations of Okitipupa has been carried out with the major objectives of establishing the subsoil/geology, evaluate the geotechnical properties and recommend appropriate foundation alternatives for building foundation construction. Seven borings were carried out with hand auger at two cone penetration test locations, and representative samples were collected and analyzed in the laboratory in accordance with relevant geotechnical engineering standards. In addition, six vertical electrical soundings (VES) were also conducted using Schlumberger configuration. The result of VES delineates three major geologic sequence comprising the topsoil/caprock, sand surficial aquifer, and sand intermediate aquifer. The topsoil has resistivity range of 242 – 1503 ohm-m and thickness of 3.4 - 20.9 m composed of clay sand and sand. This layer is capable of supporting shallow foundation such as simple spread, raft of reinforced concrete, with recommended allowable bearing pressure of 100 KN/m2 at depths of 1.0 m and 3.2 m in the northern and southern part of the study area respectively. The estimated settlement are less than 50 mm using foundation width of 0.6 m, but could be reduced by almost 50% if the width is greater than or equal to 2 m. The groundwater level is very deep (>10 m) and may not likely threatens the integrity of the foundation structures. The estimated allowable bearing capacity for strip footing (203 – 980 KN/m2), square footing (608 – 2940 KN/m2) within 1.4 m depth is appropriate. The capacity of driven (deep foundation) circular piles of diameters 400mm, 500mm, and 600mm, the recommended pile capacity varies at depth of 5 m (69 – 124 KN), 10 m (225 – 378 KN), and 15 m (470 – 766 KN), while that of bored circular pile ranges from (36 – 75 KN), 10 m (93 – 180 KN), and 15 m (170 – 317 KN).


2019 ◽  
Vol 12 (15) ◽  
Author(s):  
Maher Omar ◽  
Abdallah Shanableh ◽  
Khaled Hamad ◽  
Ali Tahmaz ◽  
Mohamed G. Arab ◽  
...  

2017 ◽  
Vol 8 (3) ◽  
pp. 143
Author(s):  
Rifki Asrul Sani

ABSTRAKSeiring dengan terjadinya longsoran di beberapa titik wilayah di bukit Hambalang, maka diperlukan kajian data kondisi geologi teknik berupa sifat fisik dan mekanik tanah serta batuan bawah permukaan, terutama mengenai daya dukung tanah dalam menahan beban bangunan di atasnya agar tidak terjadi penurunan. Metode yang digunakan dalam penelitian ini dibagi menjadi tiga, yaitu metode penelitian studio dengan memanfaatkan data-data sekunder yang telah ada, metode penelitian di lapangan melalui pemetaan geologi untuk mendapatkan data litologi yang tersingkap di permukaan, zonasi longsoran yang terjadi, dan identifikasi kekuatan tanah hasil pemboran geoteknik dengan Standard Penetration Test (SPT), serta metode penelitian di laboratorium untuk mendapatkan parameter sifat fisik dan mekanik tanah sebagai penunjang data daya dukung tanah serta geologi teknik daerah penelitian. Hasil perhitungan fondasi dangkal untuk general soil shear condition dan local soil shear condition dapat disimpulkan bahwa daya dukung tanah yang diizinkan (qa) untuk setiap kedalaman yang paling tinggi pada fondasi bujur sangkar (square footing) dan nilai tertinggi yang terdapat pada kedalaman 2 m, yaitu 57,32 ton/m2 dan 36,11 ton/m2. Fondasi yang paling rendah untuk semua kedalaman pada fondasi menerus (continuous footing) untuk kedalaman 2 m memiliki nilai 34,49 ton/m2 dan 21,25 ton/m2. Berdasarkan data SPT, nilai daya dukung yang diizinkan (qa) pada masing-masing titik bor berkisar pada rentang 2,85 ton/m2 sampai 16,85 ton/m2. Kata kunci: longsoran, daya dukung, Standard Penetration Test (SPT). ABSTRACTAlong with the landslide in some areas on the Hambalang Hill, it needs data of engineering geological study such as mechanical and physical properties of soil also subsurface rocks. Especially regarding the soil bearing capacity in order to restrain the building from settlement. There are three methods which used in this research, those are studio research by using secondary data, fieldwork research that is geological mapping conducted to obtain data on lithological rocks at surface, landslide zone and soil strength identification from geotechnical drilling with Standard Penetration Test (SPT) and laboratory research to obtain the soil parameters of physical and mechanical properties, which used to support soil bearing capacity data and engineering geology in research area. The calculation results of the shallow foundation for general soil shear condition and the local soil shear condition it could be concluded that the allowable bearing capacity for all depth which is highest at the square footing and the highest value found to a depth of 2 m, that is 57.32 ton/m2 and 36.11 ton/m2. The lowest foundation for all the depth of the continuous footing to a depth of 2 m had value 34.49 ton/m2 and 21.25 ton/m2. Based on data from SPT, the allowable bearing capacity on each of borehole ranging from 2.85 ton/m2 to 16.85 ton/m2. Keywords: landslide, bearing capacity, Standard Penetration Test (SPT).


Author(s):  
R. Hidayat ◽  
Irdhiani Irdhiani

The foundation design of Pengendalian Penduduk dan Keluarga Berencana is located on Jl. R.A. Kartini No. 100, Palu City, Central Sulawesi. In field testing using 2-point of (CPT), the value of hard-ground support at 8 – 9 m below the surface and the loads of building structures of 2 (two) floor buildings that work on the foundations are quite large, this is a consideration in choosing the type of used foundation. The point of this design is to obtain the dimensions of the pile foundation and calculate the bearing capacity of the foundation permit and settlement that meet the safety requirements. The calculation for bearing capacity of the foundation is calculated using (CPT) data and soil shear strength parameter data (c and tetha). Single pile is calculation by using the Semi-Empirical method and using Brooms Method for calculating lateral force on the driven piles. The dimensions of the foundation are planned based on the load (Qv) acting on the entire foundation. Calculation of bearing capacity of a single pile with a penetration depth of 8,20 m and varying dimensions are used in the planning. Based on the calculation of the bearing capacity of a single pile using (CPT) data on the load that works on the foundation, was obtained 25 cm and 30 cm diameter of pile. while the calculation uses ground shear strength parameter data (c and tetha) obtained pile diameter of 30 cm and diameter of 35 cm. Based on the calculation of the bearing capacity of a single pile, the dimensions of the foundation and the settlement in permits has reached the safety requirements.


2021 ◽  
Author(s):  
Hossein MolaAbasi ◽  
Aghileh Khajeh ◽  
REZA JAMSHIDI CHENARI ◽  
Meghdad Payan

Abstract Using a set of cone penetration test (CPT) records,the current paper develops a general framework based on regression analyses to model the load-settlement (q-s) behavior of shallow foundations resting on a variety of soils ranging from silty clays to sands.A three-parameter hyperbolic function is employed to rigorously examine the obtainedq-s curves, and to determine the model parameters.Also, the results of someCPT soundings, including the corrected cone tip resistance (qt) and the skin friction (Rf),are adopted to predict the results of plate load tests(PLT). The findingscorroborate the high accuracy of the proposed model, thereasonable performance of the hyperbolic function and the use of the Volterra series to predict the q-s curves.Moreover, the obtained curves from the newly developed model arecompared to those from other methods in the literature which cross-confirms the efficacyof the current model. Asensitivity analysis isalso conductedand the exclusive effects of all the contributing parameters are assessed among which Rfis shown to be the most influential. Ultimately, simple solutionsare adoptedto determine variouskey geotechnical parameters, like the ultimate bearing capacity (qult), the allowable bearing capacity (qa) andthe modulus of subgrade reaction (ks).