scholarly journals Capacitor Siting and Sizing using Cost Minimization & Monty Carlo Simulations for RDS

2019 ◽  
Vol 8 (3) ◽  
pp. 2482-2489

Capacitors are widely used in distribution networks for energy loss reduction, reactive power compensation, voltage regulation, and for system capacity release. However, it’s important that the system is designed initially, and capacitors are applied in correct magnitude and at right node to achieve best results. The most important task for distribution engineer is to efficiently simulate the system at design stage and later apply optimum capacitance injection. The work presented in this paper proposes a cost minimization algorithm using a unique mathematical model along with Monty carlo simulation to choose optimal value of capacitors, both fixed and switching based on total minimum cost algorithm.

Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1121
Author(s):  
Rozmysław Mieński ◽  
Przemysław Urbanek ◽  
Irena Wasiak

The paper includes the analysis of the operation of low-voltage prosumer installation consisting of receivers and electricity sources and equipped with a 3-phase energy storage system. The aim of the storage application is the management of active power within the installation to decrease the total power exchanged with the supplying network and thus reduce energy costs borne by the prosumer. A solution for the effective implementation of the storage system is presented. Apart from the active power management performed according to the prosumer’s needs, the storage inverter provides the ancillary service of voltage regulation in the network according to the requirements of the network operator. A control strategy involving algorithms for voltage regulation without prejudice to the prosumer’s interest is described in the paper. Reactive power is used first as a control signal and if the required voltage effect cannot be reached, then the active power in the controlled phase is additionally changed and the Energy Storage System (ESS) loading is redistributed in phases in such a way that the total active power set by the prosumer program remains unchanged. The efficiency of the control strategy was tested by means of a simulation model in the PSCAD/EMTDC program. The results of the simulations are presented.


SCITECH Nepal ◽  
2019 ◽  
Vol 14 (1) ◽  
pp. 1-7
Author(s):  
Avinash Khatri KC ◽  
Tika Ram Regmi

An electric distribution system plays an important role in achieving satisfactory power supply. The quality of power is measured by voltage stability and profile of voltage. The voltage profile is affected by the losses in distribution system. As the load is mostly inductive on the distribution system and requires large reactive power, most of the power quality problems can be resolved with requisite control of reactive power. Capacitors are often installed in distribution system for reactive power compensation. This paper presents two stage procedures to identify the location and size of capacitor bank. In the first stage, the load flow is carried out to find the losses of the system using sweep algorithm. In the next stage, different size of capacitors are initialized and placed in each possible candidate bus and again load flow for the system is carried out. The objective function of the cost incorporating capacitor cost and loss cost is formulated constrained with voltage limits. The capacitor with the minimum cost is selected as the optimized solution. The proposed procedure is applied to different standard test systems as 12-bus radial distribution systems. In addition, the proposed procedure is applied on a real distribution system, a section of Sallaghari Feeder of Thimi substation. The voltage drops and power loss before and after installing the capacitor were compared for the system under test in this work. The result showed better voltage profiles and power losses of the distribution system can be improved by using the proposed method and it can be a benefit to the distribution networks.


2018 ◽  
Vol 7 (2.28) ◽  
pp. 362
Author(s):  
Raed A. Shalwala

One of the most important operational requirements for any electrical power network for both distribution and transmission level is voltage control. Many studies have been carried out to improve or develop new voltage control techniques to facilitate safe connection of distributed generation. In Saudi Arabia, due to environmental, economic and development perspectives, a wide integration of photovoltaic (PV) genera-tion in distribution network is expected in the near future. This development in the network may cause voltage regulation problems due to the interaction with the existing conventional control system. In a previous paper, a control system has been described using a fuzzy logic control to set the on-line tap changer for the primary substation. In this paper a new control system is proposed for controlling the power factor of individual PV invertors based on observed correlation between net active and reactive power at each connection. A fuzzy logic control has been designed to alter the power factor for the remote invertors from the secondary substation to keep the feeder voltage within the permissible limits. In order to confirm the validity of the proposed method, simulations are carried out for a realistic distribution network with real data for load and solar radiation. Results showing the performance of the new control method are presented and discussed.  


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4062 ◽  
Author(s):  
Vlahinić ◽  
Franković ◽  
Komen ◽  
Antonić

Photovoltaic (PV) system inverters usually operate at unitary power factor, injecting only active power into the system. Recently, many studies have been done analyzing potential benefits of reactive power provisioning, such as voltage regulation, congestion mitigation and loss reduction. This article analyzes possibilities for loss reduction in a typical medium voltage distribution system. Losses in the system are compared to the losses in the PV inverters. Different load conditions and PV penetration levels are considered and for each scenario various active power generation by PV inverters are taken into account, together with allowable levels of reactive power provisioning. As far as loss reduction is considered, there is very small number of PV inverters operating conditions for which positive energy balance exists. For low and medium load levels, there is no practical possibility for loss reduction. For high loading levels and higher PV penetration specific reactive savings, due to reactive power provisioning, increase and become bigger than additional losses in PV inverters, but for a very limited range of power factors.


Author(s):  
Sunday Adeleke Salimon ◽  
Abiodun Aderemi Baruwa ◽  
Saheed Oluwasina Amuda ◽  
Hafiz Adesupo Adeleke

Optimal allocation of shunt capacitors in the radial distribution networks results in both technical and economic benefits. This paper presents a two-stage method of Loss Sensitivity Factor (LSF) and Cuckoo Search Algorithm (CSA) to find the optimal size and location of shunt capacitors with the objective of minimizing cost due to power loss and reactive power compensation of the distribution networks. The first stage utilizes the LSF to predict the potential candidate buses for shunt capacitor placement thereby reducing the search space of the second stage and avoiding unnecessary repetitive load flow while the second stage uses the CSA to find the size and actual placement of the shunt capacitors satisfying the operating constraints. The applicability of the proposed two stage method is tested on the standard IEEE 33-bus and Ayepe 34-bus Nigerian radial distribution networks of the Ibadan Electricity Distribution Company. After running the algorithm, the simulation results gave percentage real and reactive power loss reduction of 34.28% and 28.94% as compared to the base case for the IEEE 33-bus system while the percentage real and reactive power loss reduction of 22.89% and 21.40% was recorded for the Ayepe 34-bus system. Comparison of the obtained results with other techniques in literatures for the standardized IEEE 33-bus reveals the efficiency of the proposed method as it achieved technical benefits of reduced total power loss, improved voltage profile and bus voltage stability, and the economic benefit of reduced total cost due to electrical power loss and compensation.


Sign in / Sign up

Export Citation Format

Share Document