scholarly journals Efficient Transient Simulation of Single-Phase Grid-Feeding Converter System Using Frequency Response Optimized Integrators Considering Second Order Derivative

Author(s):  
Sheng Lei ◽  
Alexander Flueck

<p>A novel power system transient simulation scheme based on frequency response optimized integrators considering second order derivative is applied to a single-phase grid-feeding converter system in this paper. The converter system under study is introduced in detail as well as how the different numerical integrators are utilized for each constituting component. Numerical case studies show that the novel transient simulation scheme is able to achieve computational efficiency without sacrificing accuracy.</p><p><br></p><p></p><p>This paper has been accepted by the 2021 IEEE PES Innovative Smart Grid Technologies Conference.</p><p></p>

2021 ◽  
Author(s):  
Sheng Lei ◽  
Alexander Flueck

<p>A novel power system transient simulation scheme based on frequency response optimized integrators considering second order derivative is applied to a single-phase grid-feeding converter system in this paper. The converter system under study is introduced in detail as well as how the different numerical integrators are utilized for each constituting component. Numerical case studies show that the novel transient simulation scheme is able to achieve computational efficiency without sacrificing accuracy.</p><p><br></p><p></p><p>This paper has been accepted by the 2021 IEEE PES Innovative Smart Grid Technologies Conference.</p><p></p>


2021 ◽  
Vol 28 (3) ◽  
pp. 032504
Author(s):  
T. Nishizawa ◽  
M. Cavedon ◽  
R. Dux ◽  
F. Reimold ◽  
U. von Toussaint ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Zamir G. Khan ◽  
Amod S. Patil ◽  
Atul A. Shirkhedkar

Four simple, rapid, accurate, precise, reliable, and economical UV-spectrophotometric methods have been proposed for the determination of tadalafil in bulk and in pharmaceutical formulation. “Method A” is first order derivative UV spectrophotometry using amplitude, “method B” is first order derivative UV spectrophotometry using area under curve technique, “method C” is second order derivative UV spectrophotometry using amplitude, and “method D” is second order derivative UV spectrophotometry using area under curve technique. The developed methods have shown best results in terms of linearity, accuracy, precision, and LOD and LOQ for bulk drug and marketed formulation as well. In N,N-dimethylformamide, tadalafil showed maximum absorbance at 284 nm. For “method A” amplitude was recorded at 297 nm while for “method B” area under curve was integrated in the wavelength range of 290.60–304.40 nm. For “method C” amplitude was measured at 284 nm while for “method D” area under curve was selected in the wavelength range of 280.80–286.20 nm. For methods A and B, tadalafil obeyed Lambert-Beer’s law in the range of 05–50 μg/mL while for “methods C and D”, tadalafil obeyed Lambert-Beer’s law in the range of 20–70 μg/mL, and-for “methods A, B, C, and D” the correlation coefficients were found to be > than 0.999.


Sign in / Sign up

Export Citation Format

Share Document